1. Introduzione
This manual provides essential instructions for the safe installation, operation, and maintenance of your LuxeBath Sahara Curved Bathroom Radiator. Please read this manual thoroughly before installation and retain it for future reference.
The LuxeBath Sahara radiator is designed to provide efficient heating and towel warming in bathrooms and other living spaces. It features a curved design with lateral connections and is suitable for both central heating systems and electric operation (with an appropriate heating element, sold separately).

2. Informazioni sulla sicurezza
- Installation must be performed by a qualified professional in accordance with local building and electrical regulations.
- Ensure the wall structure can support the weight of the radiator when filled with water.
- Non coprire il radiatore con materiali infiammabili.
- Keep children away from the radiator when it is hot to prevent burns.
- If used with an electric heating element, ensure it is correctly installed and grounded. The heating element is not included with this product.
- Always disconnect power before performing any maintenance or repairs on an electrically operated radiator.
3. Contenuto della confezione
Verificare che tutti i componenti siano presenti prima di iniziare l'installazione:
- LuxeBath Bathroom Radiator
- 1/2 inch Bleed Valve
- 1/2 inch Blanking Plug
- Istruzioni di montaggio (questo manuale)
- Kit di montaggio a parete:
- 4 staffe da parete
- 4 viti e tasselli
- 4 x Support Screws
- 4 x Rondelle

4. Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Modello | Lusso-135 |
| Tipo di connessione | Lateral connection, 1/2 inch threaded connection |
| Progetto | Curvo |
| Colore | Bianco |
| Materiale | Acciaio di alta qualità |
| Larghezza | 400 millimetri |
| Altezza | 1200 millimetri |
| Distanza di connessione | 255 millimetri |
| Diametro del tubo | Diametro 22 mm |
| Vertical D-Profiles | Dimensioni: 30 x 40 x 1.5 mm |
| Horizontal Round Tubes | 22 x 1.2 millimetri |
| Potenza termica | 350 W (1194 BTU) |
| Volume d'acqua | 4.46 L |
| Peso | 6.79 kg |
| Max. Pressione di esercizio | 10 bar (1 MPa) |
| Pressione di prova | 12 bar (1.2 MPa) |
| Distanza dal muro | Circa 5 cm |
| Mounting Depth (wall to tube center) | da 75 a 100 mm |

5. Installazione
5.1 Controlli pre-installazione
- Ensure the chosen installation location has adequate wall strength to support the radiator.
- Verify that the plumbing connections (for central heating) or electrical supply (for electric operation) are correctly positioned and accessible.
- Unpack all components and check against the "Package Contents" list.
5.2 Montaggio del radiatore
- Marcatura dei fori di perforazione: Refer to the technical drawing (Figure 3) and the provided mounting template (if applicable) to mark the positions for the wall brackets on your wall. Ensure the marks are level and correctly spaced for the radiator's connections.
- Perforazione: Drill holes at the marked positions using an appropriate drill bit for your wall type. Insert the wall plugs into the drilled holes. Note: Deep wall plugs are not suitable for drywall installation.
- Fissaggio delle staffe: Fissare le staffe alla parete utilizzando le viti in dotazione. Assicurarsi che siano saldamente fissate.
- Posizionamento del radiatore: Carefully lift the radiator and position it onto the installed wall brackets. Ensure it sits securely.
- Connecting Plumbing (Central Heating): Connect the radiator to your central heating system's flow and return pipes. Use appropriate sealing materials (e.g., PTFE tape) to ensure watertight connections.
- Installing Bleed Valve and Blanking Plug: Screw the 1/2 inch bleed valve into the top connection point and the 1/2 inch blanking plug into the bottom connection point on the radiator. Tighten securely.
- Electric Operation (Optional): If operating electrically, install a suitable electric heating element (not included) into one of the bottom connections, following the element manufacturer's instructions. Ensure all electrical work is done by a qualified electrician.


6. Funzionamento
6.1 Central Heating System
- Once installed and connected to the central heating system, slowly open the valves to allow water to fill the radiator.
- Use the bleed valve at the top of the radiator to release any trapped air until water starts to emerge. Close the bleed valve.
- Controllare che tutti i collegamenti non presentino perdite.
- The radiator will now heat up as part of your central heating system.
6.2 Electric Operation (with heating element)
- Ensure the radiator is filled with the appropriate heat transfer fluid (if required by the heating element manufacturer) and the heating element is correctly installed.
- Bleed any air from the radiator as described for central heating.
- Connect the heating element to the electrical supply according to the manufacturer's instructions and local electrical codes.
- Operate the radiator using the controls on the electric heating element.
7. Manutenzione
- Pulizia: The powder-coated steel finish is easy to clean. Use a soft, damp panno e detergente delicato. Evitare detergenti abrasivi o prodotti chimici aggressivi che potrebbero danneggiare la finitura.
- Sanguinamento: Regularly bleed your radiator (for central heating systems) to remove trapped air, which can reduce heating efficiency.
- Ispezioni: Periodically check all connections for signs of leaks or corrosion. Address any issues promptly.
8. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Radiator not heating evenly or fully. | Aria intrappolata nel sistema. | Bleed the radiator using the bleed valve until water flows steadily. |
| Perdite d'acqua dai collegamenti. | Loose connections or insufficient sealing. | Tighten connections. If necessary, drain the system, re-seal connections with PTFE tape, and refill. Consult a professional if leaks persist. |
| Radiator not heating at all (central heating). | System not turned on, valve closed, or system pressure too low. | Check central heating system operation. Ensure radiator valves are open. Check system pressure and repressurize if needed. |
| Radiator not heating at all (electric). | No power to heating element, faulty element, or incorrect wiring. | Check power supply. Consult a qualified electrician to inspect the heating element and wiring. |
9. Garanzia e supporto
For warranty information and customer support, please refer to your purchase documentation or contact LuxeBath customer service directly. Keep your proof of purchase for any warranty claims.
Produttore: LuxeBath
Numero modello: Lusso-135