Thank you for choosing the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light. This manual provides essential information for the safe installation, operation, and maintenance of your new flood light. Please read these instructions thoroughly before installation and retain them for future reference.

2. Informazioni sulla sicurezza

AVVERTIMENTO: Rischio di scossa elettrica. Scollegare l'alimentazione dal fusibile o dall'interruttore automatico prima dell'installazione o della manutenzione.

  • Installation must be performed by a qualified electrician or person familiar with the construction and operation of the product and the hazards involved.
  • Garantire la fornitura voltage è corretto (120 V CA).
  • Non installare vicino a materiali combustibili.
  • Durante l'installazione indossare occhiali e guanti di sicurezza.
  • Questo apparecchio è progettato per l'uso esterno ed è impermeabile con grado di protezione IP65.

3. Contenuto della confezione

Verificare che tutti i componenti siano presenti prima di iniziare l'installazione:

  • Lampada (1)
  • Staffa di montaggio (1)
  • Viti (varie dimensioni)
  • Dadi in filo (3)
  • Manuale di istruzioni (1)

4. Prodotto finitoview

The OREiN Flood Light features three adjustable LED heads and a motion sensor for comprehensive outdoor illumination and security.

OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light

Figura 1: Fronte view of the OREiN 4500LM/30W Hardwired Motion Sensor LED Flood Light, showing the three adjustable light heads and the motion sensor below.

Flexible Adjustment Angle of OREiN Flood Light

Figure 2: Diagram illustrating the flexible adjustment angles of the three light heads (340°) and the motion sensor (270° horizontally, 120° vertically).

5. Installazione

This flood light is designed for hardwired installation on a standard junction box (2.75” / 3.5”). It supports both wall and eave mounting.

Fasi di installazione:

  1. Spegni l'alimentazione: Disconnect power at the circuit breaker before starting.
  2. Staffa di montaggio sicura: Attach the metal mounting bracket to your existing junction box using the provided screws.
  3. Collegare i fili: Connect the household wiring to the fixture wires using the provided wire nuts. Typically, black to black (live), white to white (neutral). This light belongs to secondary luminaires, so no extra ground wire connection is needed.
  4. Fissare l'apparecchio di illuminazione: Align the light fixture with the mounting bracket and secure it with the appropriate screws.
  5. Inserire la spina impermeabile: Ensure the waterproof plug is properly inserted to prevent moisture ingress.
  6. Regolare le teste delle luci e il sensore: Position the three light heads and the motion sensor to cover the desired areas.
  7. Ripristina alimentazione: Riattivare la corrente tramite l'interruttore automatico.
Installation Diagram for OREiN Flood Light

Figure 3: Step-by-step diagram for hardwired installation, showing mounting bracket, wire connections, and securing the fixture.

Wall Mounted and Soffit Mounted OREiN Flood Light

Figura 4: Esamples of wall-mounted and soffit-mounted installations for the flood light.

6. Modalità operative

The OREiN Flood Light offers three operational modes, selectable via a switch on the motion sensor unit:

  • Modalità di prova: The light turns on for 5 seconds when motion is detected, regardless of ambient light. Useful for testing sensor coverage during installation.
  • Modalità Dal tramonto all'alba (D2D): The light automatically turns on at night and off during the day. In this mode, the motion sensing function is inactive.
  • Modalità automatica: The light turns on only at night when motion is detected. The duration the light stays on (1, 5, or 10 minutes) can be adjusted.
OREiN Flood Light 3 Modes for Daily Lighting

Figure 5: Visual representation of Test, Dusk to Dawn, and Auto modes in operation.

OREiN Flood Light Dusk to Dawn Mode

Figure 6: Illustration of the Dusk to Dawn mode, showing the light automatically activating when surroundings are dark and deactivating when bright.

7. Regolazione delle impostazioni

The motion sensor unit includes dials for adjusting the light's duration and sensitivity:

  • Time Adjustment (Timer Minutes): Set the duration the light stays on after motion detection in Auto Mode (1, 5, or 10 minutes).
  • Sensitivity Adjustment (Sensitivity): Adjust the motion detection range (10ft, 20ft, 30ft, 40ft). Max setting provides up to 40ft detection.
Adjustable Motion Sensor Dials for OREiN Flood Light

Figure 7: Close-up of the motion sensor with dials for adjusting mode, timer minutes, and sensitivity.

Video 1: Official OREiN video demonstrating the motion sensor outdoor lights, including features like wide detection, adjustable sensing distance, heat dissipation, adjustable time/sensitivity, flexible adjustment, and easy installation.

8. Manutenzione

  • Pulizia: Pulisci l'apparecchio con un panno morbido eamp panno. Non usare detergenti abrasivi o solventi.
  • Ispezione: Periodically check for any damage to the wiring or housing.
  • Sostituzione della lampadina: The LED bulbs are integrated and not user-replaceable. The fixture has a lifespan of up to 50,000 hours.
OREiN Flood Light IP65 Waterproof

Figure 8: Illustration demonstrating the IP65 waterproof rating, showing the light functioning reliably under rain.

OREiN Flood Light Good Heat Dissipation

Figure 9: Diagram showing the heat dissipation design of the light heads, contributing to the product's longevity.

9. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
La luce non si accende.Nessuna alimentazione; cablaggio errato; impostazioni del sensore.Check circuit breaker. Verify wiring connections. Adjust sensor mode/sensitivity.
La luce rimane costantemente accesa.Sensor in D2D mode; continuous motion detected; sensitivity too high.Switch to Auto mode. Check for constant heat sources or movement in detection zone. Reduce sensitivity.
La luce si accende durante il giorno.Sensor in Test mode; ambient light sensor blocked.Switch to Auto or D2D mode. Ensure the ambient light sensor is not obstructed.
Il raggio di rilevamento del movimento è troppo breve/lungo.Sensitivity setting incorrect.Adjust the sensitivity dial on the motion sensor.

10. Specifiche

CaratteristicaDettaglio
Nome del modelloOL3600354
MarcaOREiN
Luminosità4500 lumen
Cosatage30 Watt
Temperatura del colore5000 Kelvin (luce diurna)
Voltage120 Volt
MaterialeAcrilonitrile Butadiene Stirene (ABS)
Livello di resistenza all'acquaIP65 impermeabile
Angolo di rilevamento del movimento240°
Motion Detection DistanceFino a 40 piedi
Regolazione della testa della luceCopertura a 340°
Durata stimata50,000 ore
Tipo di installazioneHardwired (Wall Mount, Eave Mount)
Dimensioni del prodotto7.6 cm L x 8 cm P x 6 cm A
Peso dell'articolo1.87 libbre

11. Garanzia e supporto

OREiN offers an extended warranty for this product. For specific warranty details, please refer to the product packaging or contact OREiN customer support.

Assistenza clienti:

  • For assistance, contact OREiN directly through Amazon or search for the brand name online.
  • If you encounter any issues, it is recommended to contact customer support before initiating a return.
OREiN Customer Service Representative

Figure 10: Image representing OREiN customer support, available for assistance.