1. Introduzione

The INFURIDER YF-5800G is a portable ammonia gas detector designed for accurate measurement of NH3 gas concentration, as well as ambient temperature and humidity. This device features a high-sensitivity sensor, a large LCD color screen for clear readings, and adjustable visual and audible alarms to ensure safety in various environments. It is equipped with a USB rechargeable lithium battery and a tripod mount for continuous monitoring.

2. Prodotto finitoview

Familiarize yourself with the components of your INFURIDER YF-5800G detector:

INFURIDER YF-5800G Ammonia Gas Detector with labeled parts

Figura 2.1: Componenti del dispositivo
This image displays the INFURIDER YF-5800G detector with key parts labeled for easy identification. These include the sensor, screen, charging port, charging indicator light, alarm indicator light, temperature unit button (°C/°F), alarm setting button, alarm value increase/decrease buttons, mode button, and power button.

  • Sensore: Located at the top, detects ammonia gas.
  • Schermo: Large LCD display showing NH3 concentration, temperature, and humidity.
  • Porta di ricarica: Porta USB per ricaricare il dispositivo.
  • Indicatore di carica: Indica lo stato di carica.
  • Indicatore luminoso di allarme: Flashes when an alarm threshold is exceeded.
  • Pulsante °C/°F: Alterna le unità di temperatura Celsius e Fahrenheit.
  • Pulsante ALLARME: Used to access and adjust alarm settings.
  • Pulsante MODE: Used to cycle through display modes and access settings like auto power-off.
  • Pulsanti su/giù: Used to adjust alarm values or navigate menus.
  • Pulsante di accensione: Accende/spegne il dispositivo.

3. Impostazione

3.1. Carica del dispositivo

Before first use, fully charge the detector. Use the provided USB cable to connect the device to a compatible USB power source.

INFURIDER YF-5800G USB Charging

Figure 3.1: USB Charging Port and Indicators
The image shows the USB charging port and the indicator lights. A green light illuminates during charging, and a red light indicates that the device is fully charged.

  • Collega il cavo USB alla porta di ricarica del dispositivo.
  • During charging, a green indicator light will be visible.
  • Once fully charged, the indicator light will turn red.

3.2. Accensione/Spegnimento

Per accendere il dispositivo, tieni premuto il pulsante di accensione finché lo schermo non si illumina. Per spegnerlo, tieni premuto nuovamente il pulsante di accensione finché lo schermo non si spegne.

4. Istruzioni per l'uso

4.1 Misurazione di base

Upon powering on, the device will automatically begin measuring and displaying the current NH3 concentration, temperature, and humidity on the LCD screen.

INFURIDER YF-5800G Measurement Display

Figure 4.1: Measurement Range and Accuracy
The display shows the ammonia concentration in ppm, along with temperature and humidity. The measurement range for NH3 is 0-100 ppm, with a resolution of 0.1 ppm and an accuracy of +/-2%.

4.2. Adjusting Alarm Settings

The device features adjustable visual and audible alarms (AL1 and AL2) for ammonia concentration. When the measured value exceeds the set alarm threshold, the device will flash and emit a beeping sound.

Video 4.2.1: Ammonia Measurement and Alarm Setting Demonstration
This video demonstrates the ammonia measurement function and how to adjust the alarm settings on a similar gas detector model. It shows the process of setting AL1 and AL2 thresholds.

  • Premere il tasto ALLARME pulsante per accedere alla modalità di impostazione della sveglia.
  • Utilizzare il Su/Giù buttons to adjust the AL1 (low alarm) and AL2 (high alarm) values.
  • Premere il tasto ALLARME button again to confirm and save the settings.

4.3. Commutazione dell'unità di temperatura

To switch between Celsius (°C) and Fahrenheit (°F) temperature units, press the ° C / ° F pulsante.

4.4. Auto Power-Off Function

The device includes an auto power-off function to conserve battery life. This can be enabled or disabled via the MODALITÀ impostazioni dei pulsanti.

Video 4.4.1: BT-5800G Ammonia Gas Detector Features
This video showcases the features of the BT-5800G, including its ammonia gas detection, temperature, and humidity measurement capabilities. It also demonstrates basic operation and settings.

  • Premere il tasto MODALITÀ button to access the auto power-off setting.
  • Utilizzare il Su/Giù buttons to select ON or OFF for the auto power-off function.
  • Conferma la selezione per salvare l'impostazione.

5. Safety Guidelines: Understanding Ammonia Levels

It is crucial to understand the potential health risks associated with different ammonia gas concentrations. The following index provides general guidance:

Ammonia Gas Human Risk Index

Figure 5.1: Ammonia Gas Human Risk Index
This chart illustrates the potential health effects of various ammonia gas concentrations on humans.

  • 100 pagine al minuto: Most people feel uncomfortable but generally harmless.
  • 250 pagine al minuto: Irritates nose, throat, eyes, and other senses.
  • 400 pagine al minuto: Eye pain and tearing can last for 30 minutes.
  • 700 pagine al minuto: The limit the human body can tolerate; prolonged exposure is not recommended.
  • 2500 pagine al minuto: Severe cough, throat, and nose inflammation; possible death within 15 minutes.

Always take appropriate safety measures when ammonia levels are elevated.

6. Ampie applicazioni

The INFURIDER YF-5800G ammonia gas detector is suitable for a variety of environments where ammonia monitoring is essential:

INFURIDER YF-5800G Applications

Figura 6.1: Aree di applicazione comuni
The image displays several environments where the YF-5800G detector can be effectively used, including construction sites, poultry farms, offices, homes, and industrial settings.

  • Agricultural Settings: Pig farms, chicken farms, livestock facilities, horse stables.
  • Industrial Environments: Workspaces, factories, and other industrial areas where ammonia may be present.
  • Residenziale e commerciale: Homes, offices, and other indoor spaces for air quality monitoring.
  • Gestione dei rifiuti: Landfills and areas with potential ammonia emissions.

7. Specifiche

Technical specifications for the INFURIDER YF-5800G Ammonia Gas Detector:

CaratteristicaSpecificazione
MarcaINFURIDO
Numero di modelloYF-5800G
Measurement Range (NH3)0 - 100 ppm
Resolution (NH3)0.1 ppm
Accuracy (NH3)+/-2%
Intervallo di temperaturaDa -10°C a 50°C (da 14°F a 122°F)
Umidità ambiente0 - 95% UR
Umidità di esercizio95% (senza condensa)
Fonte di alimentazioneBatteria al litio ricaricabile tramite USB
Tipo di allarmeVisivo e udibile
Peso dell'articoloCirca 1.1 libbre
Codice UPC734136036557
INFURIDER YF-5800G Dimensions

Figura 7.1: Dimensioni del dispositivo
This image provides a visual representation of the detector's dimensions, showing its height, width, and depth.

8. Manutenzione

Proper maintenance ensures the longevity and accuracy of your ammonia gas detector.

  • Pulizia: Pulire il dispositivo con un panno morbido e asciutto. Non utilizzare detergenti abrasivi o solventi.
  • Magazzinaggio: Quando non viene utilizzato, conservare il rilevatore in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
  • Cura della batteria: Ricaricare regolarmente la batteria, anche se il dispositivo non viene utilizzato frequentemente, per mantenerla in buone condizioni. Evitare di scaricarla completamente per periodi prolungati.
  • Protezione del sensore: Keep the sensor area clean and free from obstructions. Avoid exposing the sensor to harsh chemicals or liquids.

9. Risoluzione Dei Problemi

If you encounter issues with your INFURIDER YF-5800G, refer to the following common problems and solutions:

  • Il dispositivo non si accende: Assicurati che la batteria sia carica. Collega il dispositivo a una fonte di alimentazione USB e riprova.
  • Letture imprecise: Ensure the sensor is clean and unobstructed. Avoid using the device in environments with extreme temperature or humidity fluctuations immediately after moving it from a different environment. Allow it to stabilize.
  • L'allarme non suona: Check alarm settings (AL1, AL2) to ensure they are configured correctly. Verify that the audible alarm is enabled in the device settings.
  • Problemi di visualizzazione dello schermo: If the screen is dim or flickering, ensure the battery is charged. If the issue persists, contact customer support.

Per problemi non elencati qui, contattare l'assistenza clienti.

10. Garanzia e supporto

INFURIDER provides a warranty for this product against defects in materials and workmanship under normal use. The specific warranty period may vary by region and retailer. Please retain your purchase receipt as proof of purchase.

For technical assistance, warranty claims, or any questions regarding your INFURIDER YF-5800G Portable Ammonia Gas Detector, please contact INFURIDER customer support through the retailer where you purchased the product or visit the official INFURIDER websito per le informazioni di contatto.

Assistenza clienti: Refer to your product packaging or the INFURIDER official websito per le informazioni di contatto più aggiornate.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.