1. Introduzione
The Sinocare Safe AQ Smart Blood Glucose Monitoring System is designed for the quantitative measurement of glucose in fresh capillary whole blood samples taken from the fingertip. This system is intended for self-testing by people with diabetes at home and by healthcare professionals in clinical settings as an aid in monitoring the effectiveness of diabetes control. It provides rapid, reliable results with no coding required, making it easy to use.

Image: The Sinocare Safe AQ Smart Blood Glucose Monitoring System, including the meter, test strips, lancets, lancing device, and carrying case.
2. Cosa c'è nella scatola
Your Sinocare Safe AQ Smart diabetes test kit contains the following components:
- 1 x Sinocare Safe AQ Smart Blood Glucose Monitor
- 25 x No-coding AQ Test Strips
- 25 x lancette
- 1 x Painless Lancing Device
- 1 x Manuale utente
- 1 x Guida rapida
- 1 x Borsa per il trasporto
- 2 batterie AAA

Image: All components of the Sinocare Safe AQ Smart kit, including the meter, lancing device, test strips, lancets, and carrying case.
3. Impostazione e preparazione
3.1 Installazione delle batterie
Insert the 2 AAA batteries into the battery compartment on the back of the meter, ensuring correct polarity.
3.2 Preparazione del dispositivo pungidito
- Svitare il cappuccio del pungidito.
- Inserire saldamente una nuova lancetta sterile nel portalancetta.
- Svitare il cappuccio protettivo dalla lancetta e conservarlo per uno smaltimento sicuro.
- Riposizionare il cappuccio del dispositivo pungidito.
- Adjust the penetration depth by rotating the cap. Start with a shallower setting (e.g., 1 or 2) for softer skin and increase if needed.
- Tirare indietro la canna di armamento finché non scatta, indicando che è pronta all'uso.
3.3 Preparing the Test Strip
Remove a test strip from the vial. Close the vial immediately after removing a strip to protect the remaining strips from moisture. The meter does not require coding.
Video: A demonstration of preparing the lancing device and inserting a test strip into the Sinocare Safe AQ Smart meter.
4. Operating Instructions (Blood Glucose Test)
- Lavarsi e asciugarsi le mani: Always wash your hands thoroughly with soap and warm water, then dry them completely before testing.
- Inserire la striscia reattiva: Insert the test strip into the meter. The meter will automatically turn on and display a blood drop symbol.
- Ottieni sangue Sampon: Press the lancing device firmly against the side of your fingertip and press the release button. A small drop of blood will form.
- Applicare sangue Sampon: Gently touch the tip of the test strip to the blood drop. The blood will be automatically drawn into the strip. The meter requires only 0.6 µL of blood. If the first sample is insufficient, you have 5 seconds to apply a second drop to the same strip.
- Leggi i risultati: The meter will count down from 5 seconds and then display your blood glucose result in mg/dL.
- Risultati record: The meter automatically stores up to 99 test results with date and time.
- Smaltire i materiali usati: Eject the used lancet and test strip into a suitable sharps container.

Image: Visual steps demonstrating how to use the blood glucose meter, from inserting the strip to obtaining the result.

Image: A detailed infographic showing the simple steps for using the Sinocare Safe AQ Smart meter, emphasizing hygiene and correct application.
Video: A comprehensive guide demonstrating the full process of blood glucose testing with the Sinocare Safe AQ Smart system, from preparation to result and disposal.
5. Manutenzione e cura
5.1 Pulizia del misuratore
Pulisci l'esterno del misuratore con un panno morbido eamp cloth. If necessary, use a mild detergent or 70% isopropyl alcohol. Do not immerse the meter in water or use harsh cleaning agents.
5.2 Conservazione
Store the meter, test strips, and lancing device in their original carrying case in a cool, dry place. Keep away from direct sunlight and extreme temperatures. Ensure the test strip vial is tightly closed after each use.
5.3 Smaltimento dei materiali utilizzati
Used lancets and test strips are biohazardous waste. Always dispose of them in a puncture-resistant sharps container according to local regulations. Never reuse lancets or test strips.

Image: Illustration of the contactless ejection mechanism for lancets and test strips, promoting hygienic disposal.
6. Risoluzione Dei Problemi
If you encounter any issues with your Sinocare Safe AQ Smart system, please refer to the following common problems and solutions:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il contatore non si accende | Batterie scariche o inserite in modo errato | Controllare la polarità delle batterie o sostituirle con nuove batterie AAA. |
| Messaggio di errore sullo schermo | Striscia reattiva usata o danneggiata, sangue insufficienteample, or extreme temperature. | Utilizzare una nuova striscia reattiva, assicurarsi che il sangue sia sufficienteample, or test within operating temperature range (10-40°C). Refer to the full user manual for specific error codes. |
| Risultati imprecisi | Expired test strips, improper storage, dirty meter, or incorrect testing procedure. | Check test strip expiry date, ensure proper storage, clean the meter, and review operating instructions carefully. Perform a control solution test if available. |
| Nessun sangueample obtained | Lancing device depth too shallow or lancet not properly loaded. | Adjust lancing device depth to a higher setting. Ensure the lancet is correctly inserted and the device is cocked. |
If the problem persists, please contact Sinocare Customer Support.
7. Specifiche
- Marca: Sinocare
- Nome modello: Safe AQ Smart
- Unità di misura: mg/dl
- Tempo di funzionamento: 5 secondi
- Sangue Sampil Volume: 0.6 µl
- Capacità di memoria: 99 risultati dei test
- Composizione delle celle della batteria: Alcalino
- Fonte di energia: 2 batterie AAA
- Produttore: sinocare.inc
- Paese di origine: Cina

Image: The Sinocare Safe AQ Smart meter showing a rapid test result after 5 seconds.
8. Garanzia e supporto
8.1 Garanzia limitata
Sinocare provides a limited warranty for the Safe AQ Smart Blood Glucose Monitoring System. Please refer to the warranty card included in your kit or visit the official Sinocare websito per termini e condizioni di garanzia dettagliati.
8.2 Assistenza clienti
For any questions, technical assistance, or support regarding your Sinocare Safe AQ Smart system, please contact our customer service team. Contact information can be found in the quick guide or on the official Sinocare websito.