ABB AD1NO-R-15m (2CSM222461R1000)

ABB AD1NO-R-15m Modular Device Switch User Manual

Model: AD1NO-R-15m (Reference: 2CSM222461R1000)

Marca: ABB

1. Introduzione

The ABB AD1NO-R-15m is an analog time switch designed for daily scheduling with a 15-minute switching interval. This modular device features one normally open (NO) channel and includes a power reserve function to maintain timekeeping during power outages. It is suitable for various electrical scheduling applications.

ABB AD1NO-R-15m Modular Device Switch, front view

Figura 1: Fronte view of the ABB AD1NO-R-15m Modular Device Switch, highlighting its compact design and control interface.

2. Importanti istruzioni di sicurezza

Si prega di leggere attentamente tutte le istruzioni di sicurezza prima di installare, utilizzare o effettuare la manutenzione di questo dispositivo. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o lesioni gravi.

  • L'installazione e la manutenzione devono essere eseguite esclusivamente da personale qualificato.
  • Disconnect power before installation, maintenance, or servicing to prevent electric shock.
  • Assicurarsi che tutti i cablaggi siano conformi ai codici e alle normative elettriche locali e nazionali.
  • Non utilizzare il dispositivo se appare danneggiato.
  • Questo dispositivo è progettato per l'uso in ambienti interni asciutti.

3. Prodotto finitoview

The AD1NO-R-15m is an analog time switch with the following key features:

  • Quadrante analogico: For setting daily schedules.
  • 15-Minute Switching: Allows precise control over connected circuits with 15-minute intervals.
  • 1 Normally Open (NO) Channel: Controls one electrical circuit.
  • Riserva di carica: Maintains timekeeping for a specified duration during power interruptions.
  • Design modulare: Suitable for integration into standard electrical panels on a DIN rail.

Note: The power reserve ensures the timer continues to function accurately even if the main power supply is temporarily lost.

4. Configurazione e installazione

Follow these steps for proper installation of the AD1NO-R-15m Modular Device Switch:

  1. Disconnessione dell'alimentazione: Before beginning, ensure the main power supply to the installation area is completely disconnected at the circuit breaker or fuse box. Verify with a voltagetester.
  2. Montaggio: Mount the AD1NO-R-15m switch onto a standard DIN rail within an appropriate electrical enclosure. Ensure it is securely fastened.
  3. Cablaggio:
    • Connect the incoming phase (L) and neutral (N) wires to the designated input terminals of the time switch.
    • Connect the load wire from the output terminal of the time switch to the device you wish to control.
    • Ensure all connections are tight and secure. Refer to the wiring diagram printed on the device for specific terminal identification.
  4. Ripristino dell'energia: Once all connections are verified and secure, close the electrical enclosure and restore power to the circuit.

Always consult a qualified electrician for installation if you are unsure or lack experience with electrical wiring.

5. Istruzioni per l'uso

To set the time and program the switching schedule:

  1. Imposta ora corrente: Rotate the analog dial clockwise until the current time aligns precisely with the reference arrow or marker on the device's face.
  2. Program Switching Times: The dial features small segments around its perimeter. Push in the segments corresponding to the times you want the connected circuit to be ON. Pull out segments for OFF periods. Each segment typically represents a 15-minute interval.
  3. Operating Mode (if applicable): If your model includes a manual override switch (e.g., ON, AUTO, OFF), ensure it is set to "AUTO" for programmed operation.

The internal power reserve will automatically charge when the device is powered, ensuring continued accurate timekeeping during short power outages.

6. Manutenzione

The AD1NO-R-15m is designed for minimal maintenance. Follow these guidelines to ensure optimal performance:

  • Pulizia: Keep the device clean and free from dust. Use a dry, soft cloth for cleaning. Do not use liquid cleaners, abrasive materials, or solvents.
  • Ispezione: Periodically inspect the wiring connections for tightness and any signs of wear, corrosion, or damage. Ensure all terminals are secure.
  • Condizioni ambientali: Per evitare danni, assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.

There are no user-serviceable parts inside this device. Do not attempt to open the casing, poiché ciò invaliderà la garanzia e potrebbe esporre a rischi elettrici.

7. Risoluzione Dei Problemi

If you encounter issues with your AD1NO-R-15m switch, refer to the table below for common problems and solutions:

ProblemaPossibile causaSoluzione
Dispositivo non commutanteNessuna alimentazioneCheck the circuit breaker or fuse. Ensure wiring connections are correct and secure.
Dispositivo non commutanteProgrammazione errataRe-check the dial settings and ensure the correct segments are pushed in or pulled out for desired ON/OFF times.
Dispositivo non commutanteComando manuale attivatoSet the operating mode switch to "AUTO" for programmed operation.
L'ora è errata dopo lo spegnimentotagePower reserve depleted or faultyAllow the device to charge its power reserve by keeping it connected to power. If the issue persists, contact customer support.

If the problem persists after attempting these solutions, please contact ABB customer support for further assistance.

8. Specifiche tecniche

  • Modello: AD1NO-R-15m
  • Numero parte: Codice articolo 2CSM222461R1000
  • Produttore: FIGURA
  • Tipo: Interruttore orario analogico
  • Switching Interval: 15 minuti
  • Canali: 1 Normalmente Aperto (NO)
  • Riserva di carica:
  • Peso dell'articolo: Circa 2.82 once (80 grammi)
  • Dimensioni del prodotto: Circa 3.54 x 0.69 x 2.6 pollici (90 x 17.5 x 66 mm)
  • Tipo di montaggio: DIN Rail (Wall Mount)
  • Componenti inclusi: Modular device switch
  • Batterie richieste: No (features internal power reserve)
  • ASIN: B09BP4PFMF
  • Primo disponibile: 21 dicembre 2024

Nota: le specifiche sono soggette a modifiche senza preavviso.

9. Garanzia e supporto

Informazioni sulla garanzia

For detailed warranty terms and conditions, please refer to the official ABB warranty statement provided with your purchase or visit the official ABB websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.

Assistenza clienti

For technical assistance, troubleshooting, or service inquiries, please contact ABB customer support through their official websito o le informazioni di contatto fornite nella confezione del prodotto.

ABB Ufficiale Websito: www.abb.com