Huepar AG03
Huepar Digital Angle Gauge Protractor AG03 User Manual
Model: AG03 | Brand: Huepar
1. Introduzione
The Huepar Digital Angle Gauge Protractor AG03 is a compact and highly convenient tool designed for precise angle measurements. It is ideal for various applications including carpentry, woodworking, construction, machinery, telecommunications, and automotive repair. This electronic bevel gauge offers high accuracy and multiple measurement modes to suit diverse professional and DIY needs.
Figure 1: Huepar Digital Angle Gauge Protractor AG03 with accessories.
2. Caratteristiche principali
- Two Measuring Modes & High Accuracy: Features Single Axis Mode and Dual Axis Bubble Mode for versatile measurement. Offers 0.1° accuracy at 0°~90° and 0.2° at other angles, with 0.01° resolution.
- Five Units & Backlit LCD & Audible Alert: Supports measurements in degrees (°), percentage (%), mm/m, in/ft (fraction), and in/ft (decimal). Large backlit LCD ensures clear readings in any lighting. An audible alert function can be set for specific angle ranges.
- Magnetic V-Groove Base & Self-Inverting Display: Equipped with powerful magnetic V-groove bases on the top and bottom for secure attachment to various metal surfaces, including pipes. The display automatically inverts for easy reading when the device is upside down.
- Hold & Zero Function: Allows users to hold the current measurement value on the display and set a relative zero angle on any reference surface.
- Design portatile: Compact pocket size with a portable pouch for easy transport and use in tight spaces.
Figure 2: The AG03 is a high-precision angle finder suitable for various applications like timber processing, machine manufacturing, vehicle repair, and home decoration.
Figure 3: The device features an electronic level bubble and supports both Bubble Vial Mode and Dual Axis Bubble Vial Mode for comprehensive measurements.
Figure 4: The AG03 offers five units of measurement: degrees, percentage, mm/m, in/ft (fraction), and in/ft (decimal).
Figure 5: The display automatically reverses in five directions for convenient readings from any orientation.
Figure 6: The strong built-in magnets and V-groove design allow for secure attachment to flat and cylindrical metal surfaces.
Figure 7: The buzzer alarm function can be activated or deactivated by long-pressing the HOLD button, allowing for an audible alert within a set angle range (0-90°).
3. Impostazione
3.1. Installazione della batteria
The Huepar AG03 is powered by two AAA batteries (included). To install or replace batteries:
- Individuare il vano batteria sul retro del dispositivo.
- Use the included screwdriver to unscrew the battery compartment cover.
- Inserire due batterie AAA, assicurandosi della corretta polarità (+/-).
- Riposizionare il coperchio e fissarlo con la vite.
Figure 8: Illustration of the battery compartment and the process of installing AAA batteries using the provided screwdriver.
4. Istruzioni per l'uso
Familiarizzare con i pulsanti e il display del dispositivo:
Figure 9: Labeled components of the Huepar AG03, including LCD Display, Mode Button, Hold Button, Power Button, Reference Button, and V-Groove Magnetic Base.
4.1. Accensione/spegnimento
Premere il tasto Pulsante di accensione (
) to turn the device on or off. The LCD will light up.
4.2. Modalità di misurazione
The AG03 supports two primary measuring modes:
- Single Axis Mode (Bubble Vial Mode): Displays the angle along one axis. The electronic bubble vial on the display provides an indication for easier leveling.
- Dual Axis Bubble Vial Mode: Measures angles in five directions, providing readings for both X and Y axes, useful for complex leveling tasks.
Figure 10: Display in Bubble Vial Mode, showing a single axis measurement.
Figure 11: Display in Dual Axis Bubble Vial Mode, showing X and Y axis measurements.
4.3. Selezione dell'unità
Premere il tasto Pulsante Modalità (
) repeatedly to cycle through the five available measurement units:
- Gradi (°)
- percentualetage(%)
- Millimetri per metro (mm/m)
- Inches per foot (in/ft - Fraction)
- Inches per foot (in/ft - Decimal)
Figura 12: Esamples of the display showing different measurement units.
4.4. Zero Function (Relative Measurement)
The zero function allows you to set a relative zero angle on any surface. This is useful for measuring the angle difference between two surfaces.
- Place the device on your desired reference surface.
- Premere il tasto Pulsante di riferimento (
) to set the current position as 0.00°. - Move the device to the new surface to measure the relative angle.
Figure 13: Absolute measurement example, where 0.00° is true level.
Figure 14: Relative measurement example, where the reference surface is set to 0.00°.
4.5. Mantieni la funzione
Premere il tasto Tieni premuto il pulsante (
) to freeze the current measurement on the display. Press it again to release and resume live measurement.
4.6. Audible Alert
Premere a lungo il tasto Tieni premuto il pulsante to turn the audible alert function ON or OFF. When ON, the device will emit a sound when the measured angle falls within the set alarm range (0-90°).
Figure 15: Visual representation of the buzzer alarm function being turned ON or OFF.
5. Manutenzione
- Pulizia: Pulire il dispositivo con un panno morbido e asciutto. Non utilizzare detergenti abrasivi o solventi.
- Magazzinaggio: Store the angle gauge in its portable pouch in a dry, cool place when not in use. Remove batteries if storing for extended periods to prevent leakage.
- Calibrazione: While the device is factory calibrated, refer to the full user manual for advanced calibration procedures if accuracy issues arise.
6. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| "Erro" message on display | Device is held at an extreme angle or moved too quickly during power-on. | Place the device on a flat, stable surface and power it on again. Ensure minimal movement during startup. |
| Letture imprecise | Device needs recalibration or is on an unstable surface. | Ensure the surface is stable. Perform a zero calibration on a known level surface. Refer to the full user manual for factory calibration steps if needed. |
| Display non illuminato | Batterie scariche o esaurite; installazione errata delle batterie. | Sostituire le batterie con nuove batterie AAA, assicurandosi della corretta polarità. |
| Cicalino non funzionante | La funzione buzzer è disattivata. | Long-press the HOLD button to activate the buzzer function. |
7. Specifiche
| Attributo | Dettaglio |
|---|---|
| Measuring Range (Single Axis) | 4 x 90° (0 ~ 360°) |
| Measuring Range (Dual Axis) | -40° ~ 40° |
| Risoluzione | 0.01° |
| Accuracy (Single Axis) | ±0.1° at 0° ~ 90°, ±0.2° at other angles |
| Accuracy (Dual Axis) | ±0.2° |
| Unità di misura | Degrees (°), Percentage (%), mm/m, in/ft (Fraction), in/ft (Decimal) |
| Display | Upgraded LCD Display with Backlit |
| Temperatura di lavoro | da 32°F a 104°F (da 0°C a 40°C) |
| Metodo di potenza | Batterie 2 x AAA (incluse) |
| Dimensioni (L x P x A) | Circa 68 x 62 x 32 mm (2.68 x 2.44 x 1.26 pollici) |
| Materiale | Acrilonitrile Butadiene Stirene (ABS) |
8. Garanzia e supporto
Huepar is committed to providing high-quality tools and excellent customer service.
- Garanzia: This product comes with a 2 or 3-year free repair or replacement warranty.
- Supporto tecnico: Lifetime technical support is available for all Huepar products.
- Contatta l'assistenza: For any issues or support inquiries, please refer to the contact information provided in the full user manual or visit the official Huepar store.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.