BFT P125002 SB-BAT

Manuale utente del kit di backup della batteria 24 V CC per apricancello BFT P125002 SB-BAT

Model: P125002 SB-BAT

1. Prodotto finitoview

The BFT SB-BAT (P125002) is a 24v DC battery backup system designed to ensure continuous operation of your gate opener even during power outages. This kit provides a reliable power source, activating automatically when the main power supply is interrupted and recharging when power is restored.

It is compatible with various BFT gate opener models, including the Deimos BT series, VIRGO - LINX, EOS-SCE, HYDRA N, DEIMOS BT-QSC D-NETTUNO S, SB BAT/SB CARBAT (DEIMOS BT-SB 300), BT BAT 2 (URANO BT ARES 1000 & ARES 1500) NETTUNO B, VENERE D, ARGO, LIBRA C MA - LIBRA C LX.

BFT P125002 SB-BAT Battery Backup Kit components

Figure 1: Contents of the BFT P125002 SB-BAT Battery Backup Kit, including batteries, wiring, and mounting hardware.

2. Configurazione e installazione

Installation of the BFT SB-BAT kit is designed to be straightforward. It integrates with your existing BFT gate opener system.

2.1. Precauzioni di sicurezza

  • Ensure the main power to the gate opener is disconnected before beginning installation.
  • Indossare adeguati dispositivi di protezione individuale (DPI).
  • Refer to your specific gate opener's manual for compatibility and connection points.

2.2. Fasi di installazione

  1. Disimballare i componenti: Carefully remove all items from the packaging. Verify all components are present as shown in Figure 1.
  2. Mount the Battery Housing: Securely mount the battery housing unit near your gate opener's control board, ensuring it is protected from environmental elements.
  3. Collegare le batterie: Insert the two 12V 1.2Ah batteries into the housing. Connect them according to the wiring diagram provided with the kit (typically in series to achieve 24V DC).
  4. Connect to Gate Opener: Connect the battery backup system's wiring to the designated battery input terminals on your BFT gate opener's control board. Consult your gate opener's manual for precise terminal locations.
  5. Cablaggio sicuro: Ensure all wiring is neatly routed and secured to prevent accidental disconnections or damage.
  6. Ripristina alimentazione: Once all connections are secure and verified, restore main power to the gate opener. The smart charger board will begin charging the batteries.
Close-up of BFT P125002 SB-BAT components including batteries and wiring

Figura 2: Uno sguardo più da vicino view of the battery backup kit components, highlighting the batteries and connection wires.

3. Funzionamento

The BFT SB-BAT battery backup system operates automatically to provide uninterrupted gate functionality.

  • Funzionamento normale: When main power is available, the smart charger board continuously charges and maintains the batteries.
  • potere fuoritage: In caso di mancanza di correntetage, the system automatically switches to battery power, allowing the gate opener to continue functioning normally.
  • Ripristino dell'energia: Once main power is restored, the system automatically switches back to main power and resumes charging the batteries.

4. Manutenzione

Regular maintenance ensures the longevity and reliability of your battery backup system.

  • Ispezione visiva: Periodically inspect the batteries and wiring for any signs of damage, corrosion, or loose connections.
  • Pulizia: Keep the battery housing and terminals clean and free of dust or debris.
  • Controllo dello stato della batteria: While the system has an intelligent charger, it is advisable to periodically test the battery backup by temporarily disconnecting main power to ensure the gate operates on battery power. Reconnect main power after testing.
  • Sostituzione della batteria: Batteries have a finite lifespan. If you notice a significant decrease in backup operation time, it may be time to replace the batteries. Use only recommended replacement batteries (2x 12V 1.2Ah).

5. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your BFT SB-BAT battery backup kit.

ProblemaPossibile causaSoluzione
Gate does not operate during power outage.
  • Le batterie non vengono caricate.
  • Collegamenti elettrici allentati o errati.
  • Batteries are at end of life.
  • Fusibile bruciato.
  • Ensure main power is connected and the charger board is functioning. Allow 12-14 hours for full charge.
  • Check all wiring connections between the battery kit and the gate opener.
  • Test batteries; replace if necessary.
  • Controllare e sostituire il fusibile da 20 A se bruciato.
Batteries do not seem to be charging.
  • Problema con l'alimentazione principale.
  • Faulty charger board.
  • Collegamento errato della batteria.
  • Verify main power to the gate opener.
  • Contact BFT support for charger board diagnosis.
  • Recheck battery wiring according to the manual.

6. Specifiche

Key technical specifications for the BFT SB-BAT (P125002) battery backup system:

  • Modello: P125002 SB-BAT
  • Volume di sistematage: 24V CC
  • Volume di caricatage: 27.2V
  • Corrente di carica: 130mA
  • Capacità della batteria: 2x (12V 1.2Ah)
  • Exhausted Battery Protection Threshold: 20.4V
  • Tempo di ricarica della batteria: 12-14 ore
  • Fuse: 20A
  • Produttore: BFT

7. Garanzia e supporto

For warranty information or technical support, please refer to the documentation included with your purchase or contact BFT customer service directly. Keep your proof of purchase for warranty claims.

You can find more information about BFT products on their official websito o tramite distributori autorizzati.

© 2024 BFT. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.