RME ADI2FS

RME ADI-2 FS High Precision AD/DA Converter User Manual

Model: ADI2FS

Marca: RME

Introduzione

The RME ADI-2 FS is a compact and highly flexible 2-channel Hi-End AD/DA-converter designed for professional audio applications. It provides first-class analog-to-digital and digital-to-analog conversion at sample rates up to 192 kHz, supporting SPDIF, AES, and ADAT formats. This device features an analog bypass mode, accommodating levels up to +22dBu, and facilitates conversion between balanced and unbalanced analog signals. Its versatile connectivity ensures broad compatibility, making it a universal solution for various audio setups.

Impostare

This section details the initial steps for setting up your RME ADI-2 FS converter.

1. Disimballaggio e ispezione

Carefully remove the ADI-2 FS from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. Ensure all included accessories, such as the power supply, are present.

2. Collegamento elettrico

Collegare l'alimentatore fornito al ENERGIA input on the rear panel of the ADI-2 FS. The power plug features a locking mechanism; insert it at the correct angle and twist to secure it firmly in place. This prevents accidental disconnection. Connect the power supply to a suitable electrical outlet.

RME ADI-2 FS front and rear view

Immagine: Anteriore e posteriore view of the RME ADI-2 FS, showing the power input on the rear panel.

3. Analog Input Connections

Connect your analog audio sources to the INGRESSI ANALOGICI on the rear panel. The ADI-2 FS features two balanced XLR/TRS combo jacks for Left (L) and Right (R) channels. Ensure your cables are securely connected.

RME ADI-2 FS rear panel connections

Immagine: Close-up of the RME ADI-2 FS rear panel, highlighting the analog input and output connections.

4. Analog Output Connections

Connect your monitoring system (e.g., studio monitors) to the USCITE ANALOGICHE on the rear panel. These consist of two balanced XLR outputs for Left (L) and Right (R) channels, and two unbalanced RCA outputs. Choose the appropriate connection type for your equipment.

5. Digital I/O Connections

The ADI-2 FS offers various digital input/output options:

  • AES-3 / SPDIF: Use the coaxial RCA connectors for AES/EBU (with adapter) or SPDIF signals.
  • ADAT (Ch. 1/2): Use the optical TOSLINK connectors for ADAT signals.

Connect your digital audio devices accordingly to the I/O DIGITALI sezione sul pannello posteriore.

Istruzioni per l'uso

This section covers the primary functions and controls of the RME ADI-2 FS.

1. Pannello frontale sopraview

RME ADI-2 FS front panel

Immagine: Front panel of the RME ADI-2 FS, showing controls and indicators.

  • ANALOG INPUT (DIG) Level Meters: Displays input levels for Left (L) and Right (R) channels. The OVR (Overload) indicator illuminates when the signal is too high.
  • LEVEL Knob (Analog Input): Adjusts the input gain for analog signals.
  • CLOCK Section: Indicators for sample rates (32, 44.1, 48, QS, DS) and clock source (COAX, OPT).
  • DIG IN / DIG OUT Buttons: Selects digital input and output formats (ADAT, PRO, CON).
  • ANALOG OUTPUT (D/A MONITOR) Level Meters: Displays output levels.
  • LEVEL Knob (Analog Output): Adjusts the output level for analog signals.
  • VOL Knob (Headphones): Controlla il volume dell'uscita cuffie.
  • TELEFONO Jack: Collega qui le tue cuffie.

2. Input and Output Level Settings

The ADI-2 FS features three distinct settings for input and output levels (+4 dBu, +13 dBu, +19 dBu) to ensure optimal compatibility with various analog equipment. Adjust these settings as needed to match the nominal operating levels of your connected devices and prevent clipping or low signal-to-noise ratios.

3. Digital Connectivity and Format Conversion

The coaxial RCA SPDIF I/O offers a switchable Channel Status, allowing it to be fully AES/EBU compatible (a cable adapter may be required). When the input selection is set to DIG, the device functions as a digital format converter, enabling simultaneous monitoring of the converted signal.

4. Uscita cuffie

The High Power² headphone circuitry provides robust performance with up to 0.7 watts per channel, a 0.1 ohm output impedance, and a maximum output level of +19 dBu. This ensures compatibility with a wide range of headphones. Adjust the VOL manopola per impostare il livello di ascolto desiderato.

5. Cronometraggio

The ADI-2 FS is equipped with custom-built digital clocking for excellent performance across all clock modes. Ensure your clock source is correctly selected (e.g., internal, COAX, OPT) and that the sample rate matches your session settings (32 kHz, 44.1 kHz, 48 kHz, or higher via QS/DS modes).

Manutenzione

Proper maintenance ensures the longevity and optimal performance of your RME ADI-2 FS.

  • Pulizia: Utilizzare un panno morbido e asciutto per pulire l'esterno dell'unità. Evitare detergenti abrasivi o solventi, che possono danneggiare la finitura.
  • Ventilazione: Ensure the unit has adequate ventilation to prevent overheating. Do not block the ventilation grilles.
  • Ambiente: Operate the ADI-2 FS in a clean, dry environment, away from extreme temperatures, humidity, and direct sunlight.
  • Connessioni via cavo: Periodically check all cable connections for security and integrity. Loose connections can lead to signal loss or noise.

Risoluzione dei problemi

This section provides solutions to common issues you might encounter with your RME ADI-2 FS.

ProblemaPossibile causa/soluzione
Nessun potere
  • Ensure the power adapter is securely connected to both the unit and the electrical outlet. Remember the locking mechanism on the unit's power input.
  • Controllare se la presa di corrente funziona.
Nessuna uscita audio
  • Verify that the correct input source (Analog or Digital) is selected.
  • Check all analog and digital cable connections.
  • Ensure output levels (main and headphone) are not set to minimum.
  • Conferma che la sample rate and clock source are correctly configured and synchronized with your connected devices.
  • Check the OVR indicators on the input meters; if constantly lit, reduce the input level from your source.
Audio distorto
  • Reduce input levels to prevent clipping (OVR indicator).
  • Ensure output levels are not overdriving your monitoring system.
  • Verify that the analog input/output level settings (+4 dBu, +13 dBu, +19 dBu) match your connected equipment.
Headphone Output Too Loud
  • Regolare la funzione dedicata VOL knob for the headphone output. The ADI-2 FS features a powerful headphone amppiù vivace.

Specifiche

Key technical specifications for the RME ADI-2 FS.

  • Numero modello: ADI2FS
  • Peso dell'articolo: 3.52 once
  • Dimensioni del prodotto: 14 x 4 x 8 pollici
  • Conversione: 2-channel AD/DA
  • Sample Tariffe: Fino a 192 kHz
  • I / O digitale: ADAT, SPDIF (coaxial), AES (via SPDIF with adapter)
  • Analog Input Levels: +4 dBu, +13 dBu, +19 dBu
  • Analog Output Levels: +4 dBu, +13 dBu, +19 dBu
  • Potenza di uscita delle cuffie: Fino a 0.7 watt per canale
  • Impedenza di uscita delle cuffie: 0.1 ohm
  • Headphone Max Output Level: +19 dBu
  • THD (Headphone): -110 dB

Informazioni sulla garanzia

RME products are manufactured to high standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official RME websito. Conservare la prova d'acquisto per eventuali reclami in garanzia.

Supporto

For further assistance, technical support, or to download the latest drivers and firmware updates, please visit the official RME websito. In genere, lì puoi trovare risorse di supporto, FAQ e informazioni di contatto.

Official RME Websito: www.rme-audio.de

© 2024 RME. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.