1. Introduzione
This manual provides comprehensive instructions for the proper installation, operation, and maintenance of your Sartorius BCE2201-1S Entris II Essential Precision Balance. To ensure accurate and reliable performance, please read this manual thoroughly before using the device and keep it for future reference.
2. Informazioni sulla sicurezza
Observe the following safety precautions to prevent injury and damage to the balance:
- Operate the balance only in dry, indoor environments.
- Ensure the power supply matches the specifications indicated on the balance.
- Do not open the balance housing; refer servicing to qualified personnel.
- Evitare di esporre la bilancia a temperature estreme, umidità o luce solare diretta.
- Non posizionare oggetti più pesanti della capacità massima (2200 g) sul piatto di pesatura.
- Clean the balance with a soft, damp panno e detergente delicato. Evitare detergenti abrasivi o solventi.
3. Contenuto della confezione
Dopo aver disimballato il prodotto, verificare che tutti i componenti siano presenti e integri. La confezione deve contenere:
- Sartorius BCE2201-1S Entris II Essential Precision Balance
- Adattatore di alimentazione
- Piatto di pesatura
- Draft Shield (if applicable to model configuration)
- Manuale dell'utente (questo documento)
Se qualche articolo risulta mancante o danneggiato, contattare immediatamente il fornitore.
4. Impostazione
4.1 Disimballaggio e posizionamento
Carefully remove the balance from its packaging. Place the balance on a stable, level surface free from vibrations, drafts, and rapid temperature changes. Ensure adequate space around the balance for operation and maintenance.
4.2 Montaggio
Place the weighing pan onto the pan support. If your model includes a draft shield, assemble it according to the diagrams provided in the separate assembly guide or on the packaging.

Figura 1: The Sartorius BCE2201-1S Entris II Essential Precision Balance, shown with its protective draft shield and weighing pan installed. This image illustrates the typical setup of the balance ready for use.
4.3 Collegamento di alimentazione
Connect the power adapter to the balance and then plug it into a suitable electrical outlet. Allow the balance to warm up for at least 30 minutes before initial use to ensure optimal stability.
4.4 Initial Calibration (isoCAL)
The Entris II features an internal automatic calibration function (isoCAL). Upon initial power-up or after relocation, it is recommended to perform an isoCAL. Refer to the operating instructions section for details on initiating this process via the touch display.
5. Istruzioni per l'uso
5.1 Accensione/Spegnimento
- Per accendere: premere il tasto Acceso/Spento button (typically marked with a circle and vertical line symbol).
- Per spegnere: tenere premuto il tasto Acceso/Spento pulsante finché il display non si spegne.
5.2 Procedura di pesatura di base
- Ensure the weighing pan is empty and clean.
- Premere il tasto Zero button to set the display to 0.0g.
- Posizionare delicatamente l'oggetto da pesare al centro del piatto di pesatura.
- Wait for the stability indicator (usually a small circle or arrow) to appear, indicating a stable reading.
- Read the weight displayed on the LED touch screen.
5.3 Taratura
Taring allows you to subtract the weight of a container, so only the net weight of the sampviene visualizzato.
- Posizionare il contenitore vuoto sul piatto della pesata.
- Premere il tasto Tara button (often marked with a 'T' or '->0<-' symbol). The display will show 0.0g.
- Aggiungi la sample to the container. The display will show the net weight of the samplui.

Figura 2: Un dettagliato view of the Sartorius Entris II Essential Precision Balance's LED touch display, showing the current weight reading, stability indicator, and various function icons including isoCAL and Tare. This image highlights the user interface for daily operation.
5.4 Selezione delle unità
The Entris II balance supports various weighing units. To change the unit, navigate through the menu options on the LED touch display. Consult the on-screen prompts or the full digital manual for specific steps to access unit settings.
5.5 Applicazioni integrate
The Entris II features 12 built-in applications to assist with various weighing tasks. These applications can be accessed via the touch display menu. Examples include counting, percentage weighing, and density determination. Refer to the balance's on-screen help or the comprehensive digital manual for detailed instructions on using each application.
6. Manutenzione
6.1 Pulizia
Regular cleaning ensures the longevity and accuracy of your balance.
- Prima di pulire la bilancia, scollegarla dall'alimentazione.
- Utilizzare un panno morbido e privo di lanugine dampened with a mild detergent solution (e.g., soap and water) to clean the exterior surfaces.
- The weighing pan can be removed and cleaned separately with warm water and detergent. Ensure it is completely dry before re-installing.
- Do not allow liquids to enter the balance housing.
6.2 Calibrazione
The isoCAL function provides internal automatic calibration. It is recommended to perform this regularly, especially if the ambient temperature changes significantly or if high accuracy is critical for your application. Access isoCAL via the balance's menu.
7. Risoluzione Dei Problemi
Se riscontri problemi con il tuo saldo, fai riferimento ai seguenti problemi comuni e alle relative soluzioni:
- Letture instabili:
- Check for drafts, vibrations, or temperature fluctuations.
- Assicurarsi che la bilancia sia in piano e su una superficie stabile.
- Perform an isoCAL.
- Il display mostra un messaggio di errore:
- Consult the balance's on-screen help or the comprehensive digital manual for specific error code meanings.
- Try powering the balance off and on again.
- Balance Does Not Power On:
- Verify the power adapter is securely connected to both the balance and the electrical outlet.
- Controllare la presa di corrente con un altro dispositivo.
If the problem persists after attempting these solutions, contact Sartorius customer support or your authorized dealer.
8. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Modello | BCE2201-1S |
| Marca | Sartorio |
| Tipo di prodotto | Bilancia di precisione |
| Capacità | 2200 grammi |
| Leggibilità (d) | 0.1 grammi |
| Tipo di visualizzazione | Touchscreen LED |
| Caratteristiche speciali | Auto Calibration (isoCAL), 12 Built-in Applications |
| Paese di origine | Germania |
| Dimensioni del pacco | 17.5 x 13.8 x 9.8 pollici |
| Peso confezione articolo | 12.0 libbre |
9. Garanzia e supporto
For detailed warranty information and technical support, please refer to the official Sartorius website or contact your local authorized Sartorius dealer. Keep your purchase receipt and product serial number readily available when seeking support.