EverSale HRP-450-12

Mean Well HRP-450-12 Single Output Power Supply User Manual

Model: HRP-450-12 | Brand: EverSale

Introduzione

This manual provides detailed instructions for the installation, operation, and maintenance of the Mean Well HRP-450-12 Single Output Power Supply. This unit is designed to deliver a stable 12V output at 37.5A, with a total power of 450W, and features an active Power Factor Correction (PFC) function. Please read this manual thoroughly before using the product to ensure safe and efficient operation.

Importanti istruzioni di sicurezza

AVVERTIMENTO: La mancata osservanza di queste istruzioni di sicurezza può provocare scosse elettriche, incendi o lesioni gravi.

  • Ensure the power supply is disconnected from the main power source before any installation or maintenance.
  • This unit should be installed by qualified personnel only.
  • Do not operate the unit in environments with high humidity, extreme temperatures, or corrosive substances.
  • Assicurare una ventilazione adeguata per evitare il surriscaldamento. Non bloccare le aperture di ventilazione.
  • Verificare il volume immessotage and current ratings match your power source before connection.
  • Grounding is essential for safety. Ensure the FG (Frame Ground) terminal is properly connected to earth ground.
  • Non aprire l'alimentatore casing. All'interno non ci sono parti riparabili dall'utente.

Configurazione e installazione

Follow these steps for proper installation of the HRP-450-12 power supply:

  1. Montaggio: Mount the power supply in a well-ventilated area. Ensure adequate clearance around the unit for proper airflow. Refer to the mechanical specifications for dimensions and mounting hole locations.
  2. Connessione di ingresso: Connect the AC input power to the terminal block labeled "AC Input Terminal Pin No. Assignment".
    • Pin 1-3: AC/L (Live)
    • Pin 2: AC/N (Neutral)
    • Pin 3: FG (Frame Ground) - Crucial for safety.
  3. Connessione di uscita: Connect your load to the DC output terminal block labeled "DC Output Terminal Pin No. Assignment".
    • Pin 4-6: +V (Positive Output)
    • Pin 2: -V (Negative Output)
  4. Rilevamento remoto (facoltativo): For applications requiring precise voltage regulation at the load, connect the remote sense pins (CN100) to the load. Refer to the "Function Manual" section for detailed instructions.
  5. DC-OK Signal (Optional): The DC-OK signal provides a TTL level signal indicating the output status. Refer to the "Function Manual" section for connection details.
Mechanical specifications and connection diagrams for Mean Well HRP-450-12 power supply

Figure 1. Mechanical specifications, terminal assignments, block diagram, and derating curves for the HRP-450-12 power supply. This diagram illustrates the physical dimensions, input/output connections, internal block diagram, and operational limits based on ambient temperature and input voltage.

Operazione

Once the power supply is correctly installed and all connections are secure, you can power on the unit. The HRP-450-12 features several functions to ensure stable and reliable power delivery.

Funzione di rilevamento remoto

La funzione di rilevamento remoto compensa il volumetage drop across the load wiring, ensuring accurate voltage delivery at the load terminals. This is particularly useful for applications with long wiring runs or high currents.

  • Connect the +S (Pin 3 of CN100) to the positive terminal of the load.
  • Connect the -S (Pin 4 of CN100) to the negative terminal of the load.
  • The +S and -S leads should be twisted in pairs to minimize noise pick-up. The maximum line drop compensation is 0.5V.

Segnale DC-OK

The DC-OK signal is a TTL level signal that indicates the output status of the power supply. It is referenced to pin 2 (DC-OK GND) of CN100.

  • When the power supply output is within specifications, the DC-OK signal (Pin 1 of CN100) is HIGH.
  • When the output is outside specifications (e.g., due to overvoltage, sottovoltage, or no output), the DC-OK signal is LOW (0-1V).
Function description of CN100, remote sense wiring, and DC-OK signal details for Mean Well HRP-450-12 power supply

Figure 2. Detailed function description of the CN100 connector, illustrating the wiring for remote sensing and the behavior of the DC-OK signal. This diagram helps in understanding and implementing advanced control features of the power supply.

Manutenzione

The HRP-450-12 power supply is designed for long-term reliability with minimal maintenance. However, adhering to the following guidelines can extend its lifespan and ensure optimal performance:

  • Pulizia: Periodically inspect the unit for dust accumulation, especially around ventilation openings. Use a soft, dry cloth or compressed air to gently clean the exterior. Ensure the unit is powered off and disconnected before cleaning.
  • Ventilazione: Ensure that the operating environment maintains proper airflow and that the ambient temperature remains within the specified range. Blocked vents can lead to overheating and reduced lifespan.
  • Connessioni: Periodically check all input and output connections to ensure they are secure and free from corrosion. Loose connections can cause intermittent operation or damage.
  • Condizioni ambientali: Avoid exposing the power supply to excessive moisture, direct sunlight, or extreme temperatures.

No user-serviceable parts are inside. Do not attempt to open or repair the unit. Refer all servicing to qualified service personnel.

Risoluzione dei problemi

If you encounter issues with your HRP-450-12 power supply, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
Nessun volume di uscitatageNo input power; Blown fuse; Overload; Internal faultCheck AC input connections and power source; Check for tripped circuit breakers; Reduce load; Contact support if internal fault is suspected.
Volume di uscitatage too low/unstableOverload; Loose connections; Remote sense not connected or faulty; High ambient temperatureReduce load; Check all wiring connections; Verify remote sense wiring (if used); Ensure proper ventilation.
Surriscaldamento dell'unitàVentilazione insufficiente; Sovraccarico; Temperatura ambiente elevataEnsure clear airflow around the unit; Reduce load; Operate within specified temperature range.
DC-OK signal is LOWVolume di uscitatage out of range; Power supply faultControllare l'uscita voltage with a multimeter; Verify load conditions; If output is correct, check DC-OK signal wiring; Contact support if fault persists.

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti.

Specifiche

CaratteristicaDettaglio
Numero di modelloHRP-450-12
Volume di uscitatage12V
Corrente di uscita37.5A
Potenza di uscita450W
Ingresso volumetage Gamma85 ~ 264VAC (Full range)
Funzione PFCFunzione PFC attiva integrata
Limitazione di correnteCircuito di limitazione della corrente costante incorporato
TelerilevamentoBuilt-in funzione di rilevamento a distanza
Dimensioni (L x P x A)8.58 x 4.13 x 1.61 pollici (218 x 105 x 41 mm)
Metodo di raffreddamentoAir (Fan-cooled)
Temperatura di esercizioRefer to derating curve (Figure 1)
ASINB07MP3FC7T
Codice UPC888777017779

Informazioni sulla garanzia

The Mean Well HRP-450-12 power supply comes with a Garanzia di 5 anno dalla data di acquisto. La presente garanzia copre i difetti di materiali e di fabbricazione in normali condizioni di utilizzo e servizio.

La garanzia non copre i danni derivanti da:

  • Installazione o cablaggio non corretti.
  • Modifiche o riparazioni non autorizzate.
  • Operation outside of specified environmental or electrical limits.
  • Physical damage or misuse.

Per richieste di garanzia, conservare la prova d'acquisto e contattare l'assistenza clienti.

Assistenza clienti

If you have any questions, require technical assistance, or need to report a problem with your Mean Well HRP-450-12 power supply, please contact our customer support team.

Informazioni sui contatti:

  • Produttore: Buone intenzioni
  • Marca: EverSale
  • Websito: www.meanwell.com (for technical documentation and general inquiries)
  • Supporto al rivenditore: Refer to your point of purchase for specific customer service contact details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.