FLUKE 124B

FLUKE 124B/JP/S ScopeMeter 40MHz SCC Kit Instruction Manual

Modello: 124B

1. Introduzione

This manual provides essential information for the safe and efficient operation of your FLUKE 124B/JP/S ScopeMeter. Please read this manual thoroughly before using the device and keep it for future reference.

The Fluke 124B/JP/S is a compact ScopeMeter designed for industrial applications, combining the functions of a dual-input digital oscilloscope and a multimeter. It features advanced capabilities like Connect-and-View triggering and IntellaSet technology for simplified measurements.

2. Informazioni sulla sicurezza

Seguire sempre le precauzioni di sicurezza di base quando si utilizza questo prodotto per ridurre il rischio di incendi, scosse elettriche e lesioni personali. Conservare questo manuale per riferimento futuro.

  • Leggere attentamente tutte le istruzioni prima dell'uso.
  • Non utilizzare il dispositivo se appare danneggiato o non funziona correttamente.
  • Garantire una ventilazione adeguata per evitare il surriscaldamento.
  • Utilizzare solo gli accessori e gli attacchi specificati.
  • Affidare tutti gli interventi di assistenza a personale qualificato.
  • Rispettare tutte le norme di sicurezza locali e nazionali.

3. Prodotto finitoview

The FLUKE 124B/JP/S ScopeMeter is a robust and versatile tool for electrical and electronic measurements. It integrates a dual-input digital oscilloscope and a true-RMS digital multimeter into a single handheld device.

Caratteristiche principali:

  • Dual-input digital oscilloscope and multimeter.
  • Oscilloscope bandwidth: 40 MHz or 20 MHz.
  • 2-channel, 5,000 count true-RMS digital multimeter.
  • Connect-and-View™ trigger function for simple, hands-free operation.
  • IntellaSet™ technology for intelligent automatic adjustment of measurement values based on the measured signal.
  • Long-term recorder function with up to 400M samples and 15G points of data directly recordable to SD card (for 124B and 125B models), allowing up to 14 days of event saving.
FLUKE 124B/JP/S ScopeMeter and accessories

Figure 1: FLUKE 124B/JP/S ScopeMeter with included accessories, including probes, power adapter, and carrying case.

4. Impostazione

4.1 Disimballaggio e ispezione

Carefully unpack the ScopeMeter and all accessories. Inspect for any signs of damage. If any items are missing or damaged, contact your supplier immediately.

4.2 Installazione e ricarica della batteria

The device uses a Lithium-Ion battery. Ensure the battery is properly installed. Connect the power adapter to charge the device before first use. A full charge is recommended for optimal battery life.

4.3 Accensione iniziale

Press and hold the power button until the display illuminates. The device will perform a self-test. Follow any on-screen prompts for initial setup, such as language selection.

5. Istruzioni per l'uso

5.1 Modalità di misurazione di base

The ScopeMeter offers both oscilloscope and multimeter functionalities. Use the dedicated buttons to switch between modes.

Davanti view of FLUKE 124B/JP/S ScopeMeter

Figura 2: Fronte view of the FLUKE 124B/JP/S ScopeMeter, showing the display and control buttons.

5.2 Connect-and-View™ Triggering

This feature automatically identifies signal patterns and sets the correct trigger conditions. Simply connect the probes to the circuit, and the device will optimize the display. In Auto mode, it continuously tracks signal changes, providing a stable waveform display without manual adjustments.

FLUKE 124B/JP/S ScopeMeter displaying a waveform

Figure 3: The ScopeMeter displaying a complex waveform, demonstrating its measurement capabilities.

5.3 IntellaSet™ Technology

IntellaSet analyzes measured waveforms using a unique algorithm and automatically displays the most appropriate measurement values on the screen. This simplifies waveform analysis and ensures reliable verification of readings.

5.4 Long-Term Recorder Function

The recorder function allows high-speed and long-term waveform capture. It can capture up to 400M samples and record up to 15G points of data directly to an SD card (for 124B and 125B models). This enables saving up to 14 days of event data for later analysis.

5.5 Using the Multimeter

Switch to multimeter mode to perform standard electrical measurements such as voltage, current, resistance, and capacitance. Refer to the on-screen interface for specific measurement selections and ranges.

Technician using FLUKE 124B/JP/S ScopeMeter to test a circuit board

Figure 4: A technician using the FLUKE 124B/JP/S ScopeMeter to perform measurements on a circuit board.

6. Manutenzione

6.1 Pulizia

Pulire il dispositivo con un panno morbido, damp panno. Non utilizzare detergenti abrasivi o solventi. Assicurarsi che il dispositivo sia spento e scollegato da qualsiasi fonte di alimentazione prima di pulirlo.

6.2 Cura della batteria

To prolong battery life, avoid extreme temperatures and store the device with a partial charge if not used for extended periods. Replace the battery when its capacity significantly diminishes.

6.3 Conservazione

Store the ScopeMeter and its accessories in a clean, dry environment, away from direct sunlight and extreme temperatures. Use the provided carrying case for protection during transport.

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Low or depleted battery; power button not pressed correctly.Charge the battery; ensure the power button is pressed firmly for a few seconds.
Unstable waveform display.Incorrect trigger settings; poor probe connection.Ensure Connect-and-View is active or adjust trigger levels manually; check probe connections.
Letture imprecise del multimetro.Incorrect measurement mode; faulty probes.Verify the selected measurement mode; test probes for continuity or replace if damaged.
SD card recording issues.SD card full or corrupted; incorrect file formato.Check SD card capacity; format the SD card (this will erase data); try a different SD card.

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti.

8. Specifiche

CaratteristicaDettaglio
ProduttoreCOLPO DI FORTUNA
Numero di parte124B/JP/S
Peso dell'articolo1.4 chilogrammi
Dimensioni del prodotto (LxWxH)Dimensioni: 32 x 25 x 47 cm
Batterie1 batteria agli ioni di litio (inclusa)
Precisione della misurazioneRefer to catalog values
Componenti inclusiStandard accessories included
Tipo di batteriaIoni di litio
ASINB07DRL9T2M
Prima data disponibile25 gennaio 2019

9. Garanzia e supporto

9.1 Informazioni sulla garanzia

This FLUKE product is covered by a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official FLUKE websito per termini e condizioni di garanzia dettagliati.

9.2 Assistenza clienti

For technical assistance, troubleshooting, or service inquiries, please contact FLUKE customer support. Contact details can typically be found on the official FLUKE websito o nella confezione del prodotto.

Online resources and FAQs may also be available on the FLUKE support portal.

© 2023 FLUKE. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.