Liebert PSA5-1500MT120

Vertiv Liebert PSA5 UPS - 1500VA/900W User Manual

Model: PSA5-1500MT120

Brand: Liebert

Introduzione

The Vertiv Liebert PSA5 UPS (Uninterruptible Power Supply) provides reliable and cost-effective power protection for your electronic devices. This line-interactive UPS features Automatic Voltage Regulation (AVR) to extend battery life and offers battery backup with surge protection. It is designed to safeguard against power surges, brownouts, blackouts, and voltage drops, ensuring the continuous operation and safe shutdown of your critical equipment.

Prodotto finitoview

The Vertiv Liebert PSA5-1500MT120 UPS is equipped with multiple features to protect and manage your power supply:

  • Surge Protection and Battery Backup: Provides protection against power fluctuations and outages, with AVR to extend battery life. USB communication allows for notifications and controlled shutdown via free software.
  • 10 Outlets, 2 USB Charging Ports: Includes 5 surge-only outlets and 5 battery-backed & surge-protected outlets. Two outlets are widely spaced for larger transformer-block plugs. Two USB charging ports are available for mobile devices.
  • Schermo LCD: A clear LCD panel monitors real-time data such as run time, load capacity, battery status, and input/output voltage e frequenza.
  • Efficienza energetica: This UPS is Energy Star certified, meeting eco-friendly requirements and contributing to cost savings.
  • Design compatto della torre: The unit features a space-saving tower form factor suitable for various environments.

Controls and Features Diagram

Diagram showing front and back panels of Vertiv Liebert PSA5 UPS with labels for LCD display, USB charging ports, surge-protected only receptacles, USB communication port, RJ11/45 connectors, coax connectors, and battery-backed surge-protected receptacles.

This image illustrates the key controls and features on the front and back panels of the Vertiv Liebert PSA5 UPS, including various ports and outlets.

Close-up of the LCD display on the Vertiv Liebert PSA5 UPS showing input/output voltage and runtime/battery status.

Il display LCD fornisce informazioni in tempo reale sul volume di ingresso/uscitatagee lo stato della batteria.

Impostare

  1. Disimballaggio: Carefully remove the UPS unit and all accessories from the packaging.
  2. Collegamento iniziale della batteria: For safety during shipping, the internal battery may be disconnected. Locate the battery compartment (typically accessible from the front or bottom) and connect the battery terminals as instructed in the included quick start guide. Ensure proper polarity (red to positive, black to negative).
  3. Posizionamento: Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive moisture. Ensure adequate space around the unit for proper airflow.
  4. Collegamento elettrico: Plug the UPS's power cord directly into a grounded wall outlet. Avoid using extension cords or surge protectors with the UPS input.
  5. Connessione del dispositivo:
    • Plug critical equipment (e.g., computers, modems, routers) into the battery-backed & surge-protected outlets.
    • Plug non-critical equipment (e.g., printers, scanners) into the surge-only outlets.
    • Utilizzare il Porte di ricarica USB on the front for mobile devices.
    • Connect the UPS to your computer via the Porta di comunicazione USB for monitoring and controlled shutdown features using Vertiv Power Assist software.
  6. Carica iniziale: Lasciare caricare l'UPS per almeno 8 ore prima del primo utilizzo per garantire la piena capacità della batteria.

Istruzioni per l'uso

  • Accensione/spegnimento: Press and hold the power button on the front panel for a few seconds to turn the UPS on or off.
  • Schermo LCD: The LCD panel provides real-time information. Use the display buttons to cycle through different metrics such as input/output voltage, load capacity, battery charge level, and estimated run time. The display may dim or turn off after a period of inactivity to save energy; press any display button to reactivate it.
  • Volume automaticotage Regolamento (AVR): L'UPS regola automaticamente il volume alto e bassotages to safe levels without using battery power, preserving battery life for actual power outages.
  • Modalità di backup della batteria: In caso di mancanza di correntetage, the UPS will automatically switch to battery power. An audible alarm may sound, and the LCD will indicate battery mode.
  • Comunicazione USB: Connect the UPS to your computer using the provided USB cable. Download and install the Vertiv Power Assist software to enable advanced monitoring, controlled system shutdown during extended outages, and event notifications.
  • Modalità ecologica: This energy-saving feature can automatically cut off power to idle devices, reducing energy consumption and lowering utility bills. Refer to the software manual for configuration.

Manutenzione

  • Sostituzione della batteria: The UPS is designed for user-replaceable batteries. When the battery reaches the end of its service life (typically 3-5 years, or indicated by an error code like "bad battery" or "F02"), replace it with a genuine Vertiv Liebert replacement battery. Disconnect the UPS from all power sources and connected devices before attempting battery replacement. Follow the instructions in the quick start guide or the full user manual for safe replacement.
  • Pulizia: Regularly clean the exterior of the UPS with a dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.
  • Magazzinaggio: If storing the UPS for an extended period, ensure the battery is fully charged and then disconnect it. Recharge the battery every 3-6 months to prevent deep discharge and prolong its lifespan.

Risoluzione dei problemi

If you encounter issues with your Vertiv Liebert PSA5 UPS, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
L'UPS non si accende.Battery disconnected or depleted.Ensure the internal battery is properly connected. Plug the UPS into a wall outlet and allow it to charge for at least 8 hours.
Short runtime on battery.Overloaded UPS, aging battery, or insufficient charge.Reduce the connected load. Ensure the battery is fully charged. If the battery is old (over 3 years), consider replacement.
"Bad Battery" or "F02" error code.Battery has failed or is severely degraded.The battery requires replacement. Contact support or refer to the maintenance section for replacement instructions.
L'UPS emette segnali acustici continui in modalità CA.Condizione di sovraccarico.Disconnect non-essential equipment from the UPS until the alarm stops.
No power to outlets.UPS is off, circuit breaker tripped, or power outage.Turn on the UPS. Check the circuit breaker on the back of the unit and reset if tripped. Verify utility power.

Specifiche

  • Numero modello: PSA5-1500MT120
  • Capacità: 1500VA/900W
  • Ingresso volumetage: 120 Volt
  • Tipo di batteria: Lead Acid (2 Product Specific batteries required)
  • Punti vendita: 10 (5 battery-backed & surge-protected, 5 surge-only)
  • Porte di ricarica USB: 2
  • Porte di comunicazione: USB Type A to USB Type B, 2 meter (H77 ft) in length
  • Dimensioni (P x L x A): 16.2" x 3.9" x 11"
  • Peso dell'articolo: 26.5 libbre
  • Colore: Nero
  • Certificazioni: Certificato Energy Star

Garanzia e supporto

The Vertiv Liebert PSA5 UPS is backed by a 3-year full unit coverage warranty, which includes the battery, with advanced replacement. For technical support, warranty claims, or additional information, please refer to the official Liebert websito o contattare il loro servizio clienti.

© 2024 Liebert. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.