Manuale di istruzioni del sistema di pompa di scarico/lavello compatto remoto Superior Pump 92017 da 3/10 HP
Model: 92017 | Brand: Superior Pump
Introduzione
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Superior Pump 92017 3/10 HP Compact Remote Sink/Drain Pump System. Please read and understand all instructions before installation and use. Retain this manual for future reference.
Informazioni importanti sulla sicurezza
WARNING: Risk of Electrical Shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle. Always disconnect the electricity before removing or servicing this device.
AVVERTIMENTO: This unit is not built to pump corrosive or flammable liquids. Doing so can cause fire, and/or personal injury. It will also void the warranty.
AVVERTIMENTO: Questa pompa non è stata studiata per l'uso in piscine o zone marine.
ATTENZIONE: This pump is designed for indoor and outdoor use. Ensure proper ventilation and avoid operating in enclosed spaces without adequate airflow.
Componenti del prodotto
The Superior Pump 92017 system includes the following key components:
- Submersible Sump Pump: A 3/10 HP permanent split capacitor motor designed for efficient water removal.
- Interruttore a galleggiante verticale: Automatically turns the pump on and off based on water level.
- Remote Sink/Drain Basin: A durable, structural foam basin designed to collect water.
- Cavo di alimentazione da 10 piedi: Fornisce ample reach for power connection.
- Removable Intake Screen: Filters out debris to protect the impeller.
- Scarico NPT da 1-1/2": Standard pipe connection for water expulsion.

Figura 1: Oltreview of the Superior Pump 92017 Compact Remote Sink/Drain Pump System, showing the submersible pump inside the basin.

Figura 2: dettagliata view of the submersible sump pump, highlighting the oil-cooled motor, 10-foot power cords, and large side intakes.

Figure 3: Close-up of the sump pump, illustrating the vertical float switch, cast iron construction, 3/10 HP motor, 1-1/2" NPT discharge, and stainless steel impeller.
Configurazione e installazione
Proper installation is crucial for the longevity and performance of your pump system. Refer to the video below for a visual guide.
Video 1: "Install a Sump Pump" - An official guide from Superior Pump demonstrating the installation process for a sump pump.
Fasi di installazione:
- Scollegare l'alimentazione: Always unplug the old pump from the power source before beginning any work.
- Remove Old System:
- Cut the old PVC discharge pipe above the basin copertina.
- Rimuovere la basin copertina.
- Carefully remove the old pump from the basin.
- Pulisci Basin: Clean out any debris or sediment from inside the basin to ensure optimal performance of the new pump.
- Assemble New Pump: Screw the new PVC section into the new sump pump's discharge port.
- Place Pump in Basin: Carefully lower the new sump pump into the basin. In sandy or dirty pits, consider using bricks or a pump base to elevate the pump and prevent debris from entering. Effluent and sewage pumps typically do not require elevation.
- Collegare le tubazioni: Fai scorrere la basin cover over the new sump pump PVC pipe. Connect the old PVC pipe to the new PVC pipe using a rubber boot check valve.
- Regolare l'interruttore a galleggiante: Adjust the vertical float switch to the desired "on" and "off" points. Ensure the float moves freely without obstruction.
- Collegamento elettrico: Plug the float switch cord into the back of the piggy-back power cord, then plug the entire assembly into a properly grounded wall receptacle.
- Operazione di prova: Riempi il basin with water until the float switch activates the pump. The pump should empty the basin. Adjust the float switch again if the pumping range is incorrect.
Applicazioni tipiche:

Figure 4: Diagram illustrating the pump system installed for a remote sink, showing discharge and vent lines.

Figure 5: Diagram illustrating the pump system installed for a washing machine, showing connection to a laundry tub and discharge/vent lines.

Figure 6: Diagram illustrating the pump system installed for a dehumidifier or condenser, showing the connection and discharge/vent lines.
Istruzioni per l'uso
The Superior Pump 92017 operates automatically via its vertical float switch. When water in the basin reaches a predetermined level, the float switch activates the pump, which then removes the water. Once the water level drops, the float switch deactivates the pump.
- Ensure the pump is always submerged in water when operating to prevent overheating.
- Non far funzionare la pompa a secco.
- Regularly check the float switch for free movement.
Manutenzione
Una manutenzione regolare garantisce la longevità e l'efficienza della pompa.
- Ispezionare regolarmente: Periodically check the pump and basin for any signs of wear, damage, or debris accumulation.
- Pulisci lo schermo di aspirazione: The removable intake screen should be cleaned regularly to prevent clogging and maintain optimal flow.
- Controllare l'interruttore a galleggiante: Ensure the float switch is free of obstructions and moves smoothly.
- winterization: If the pump is in an area subject to freezing temperatures, ensure it is properly drained or removed and stored in a warm, dry place to prevent damage.

Figura 7: View of the pump's underside, showing the removable intake screen that filters out debris and the stainless steel impeller.
Risoluzione dei problemi
If your pump is not operating as expected, consult the following common issues and solutions:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La pompa non si accende. | No power, clogged intake, stuck float switch. | Check power connection, clean intake screen, free the float switch. |
| La pompa funziona continuamente. | Stuck float switch, check valve issue, continuous water inflow. | Check float switch, inspect check valve, identify and stop water source. |
| La pompa funziona ma non viene scaricata acqua. | Clogged discharge pipe, airlock, low water level. | Clear discharge pipe, prime the pump, ensure adequate water in basin. |
Specifiche
- Modello: 92017
- Marca: Pompa superiore
- Potenza: 3 / 10 HP
- Materiale: Plastic (Basin), Cast Iron (Pump)
- Fonte di energia: AC
- Voltage: 120 Volt
- Portata massima: 48 galloni al minuto
- Altezza massima di sollevamento: 10 piedi
- Dimensioni del prodotto: 15 cm L x 15 cm P x 13.5 cm A
- Peso dell'articolo: 17.96 libbre
- Codice UPC: 725113920174
Garanzia e supporto
All Superior Pumps are backed by a 1 to 5 year limited warranty. For specific warranty details and support, please refer to the documentation included with your product or visit the official Superior Pump websito.
For additional assistance or to purchase accessories, please contact Superior Pump customer service.
Ask a question about this manual