Dwyer DM-2002-LCD

Dwyer Series DM-2000 Differential Pressure Transmitter User Manual

Model: DM-2002-LCD

1. Introduzione

This manual provides comprehensive instructions for the installation, operation, and maintenance of the Dwyer Series DM-2000 Differential Pressure Transmitter. The DM-2000 series is designed to accurately sense the pressure of air and compatible gases, providing a standard 4-20 mA output signal. This device is ideal for various industrial and scientific applications requiring precise pressure measurement.

The DM-2000 housing is engineered for easy mounting, fitting into the same diameter cutout as a standard Magnehelic® gage. It features digital push-button zero and span adjustments for simplified calibration. Models with an optional 3.5 digit LCD display process and engineering units, with a single button allowing field selection of 4 to 6 engineering units depending on the range.

2. Informazioni sulla sicurezza

Per evitare lesioni personali e danni allo strumento, osservare sempre le seguenti precauzioni di sicurezza:

  • Assicurarsi che l'alimentazione sia scollegata prima dell'installazione o della manutenzione.
  • Only use the transmitter with air and non-combustible, compatible gases.
  • Do not exceed the specified pressure range of the device.
  • L'installazione e la manutenzione devono essere eseguite solo da personale qualificato.
  • Proteggere il dispositivo da temperature estreme, umidità e ambienti corrosivi.

3. Prodotto finitoview

Dwyer Series DM-2000 Differential Pressure Transmitter with LCD display showing 0.250 IN WC

Figura 3.1: Davanti view of the Dwyer Series DM-2000 Differential Pressure Transmitter. The device features a circular black face with a digital LCD display showing "0.250 IN WC", the "DM-2000 Pressure Transmitter" model name, and two circular buttons labeled "ZERO" and "UNITS" at the bottom. The housing is light gray.

The Dwyer Series DM-2000 is a robust differential pressure transmitter designed for precise measurement. Key components include:

  • Schermo LCD: (Optional) Provides real-time pressure readings and selected engineering units.
  • Pulsante Zero: Used for digital zero adjustment.
  • Pulsante Unità: Allows selection of various engineering units (e.g., in WC, Pa, kPa, mm WC, cm WC, psi).
  • Connessioni di pressione: Integrated into the molded housing for quick and easy installation.
  • Morsettiera elettrica: Screw-type for secure wiring.

4. Configurazione e installazione

4.1 Montaggio

The DM-2000 is designed for vertical mounting. Its housing is specifically sized to fit into the same diameter cutout as a standard Magnehelic® gage, simplifying replacement or new installations.

  • Ensure the mounting surface is stable and free from vibrations.
  • Mount the unit in a vertical orientation for optimal performance.
  • Secure the transmitter using appropriate mounting hardware (not included).

4.2 collegamenti elettrici

The transmitter provides a standard 4-20 mA output signal. Connect the power supply and signal wires to the screw-type terminal block located on the unit.

  • Refer to the wiring diagram provided with your specific model for correct polarity and connections.
  • Use appropriate gauge wiring for the power supply and signal lines.
  • Ensure all connections are secure to prevent intermittent operation.

4.3 Connessioni di pressione

Pressure connections are inherent to the glass-filled plastic molded housing. Connect the pressure tubing to the designated ports.

  • Connect the higher pressure source to the 'High' port and the lower pressure source to the 'Low' port.
  • Ensure tubing is free from kinks and leaks.
  • Verify that the gases are non-combustible and compatible with the transmitter's materials.

5. Istruzioni per l'uso

5.1 Power On and Initial Reading

Once installed and wired, apply power to the transmitter. The LCD (if present) will illuminate and display the current differential pressure reading.

5.2 Regolazione dello zero

The DM-2000 features digital push-button zero adjustment. This simplifies calibration compared to traditional potentiometers.

  1. Ensure both pressure ports are open to atmospheric pressure or connected to the same pressure source (zero differential pressure).
  2. Premere e tenere premuto il tasto ZERO button until the display shows "0.000" or a similar indication of successful zeroing.
  3. Release the button. The transmitter is now zeroed.

5.3 Span Adjustment (Calibration)

Span adjustment is typically performed at the factory. However, digital span adjustment is available for field calibration.

  1. Apply a known, stable pressure equal to the full-scale range of the transmitter to the high-pressure port, with the low-pressure port at zero.
  2. Premere e tenere premuto il tasto UNITÀ button (or a combination as per specific model instructions) to enter span adjustment mode.
  3. Adjust the reading to match the applied full-scale pressure using the appropriate buttons (consult specific model manual for exact procedure).
  4. Salvare l'impostazione.

5.4 Changing Engineering Units (LCD Models)

For models equipped with an LCD, you can cycle through available engineering units.

  • Premere momentaneamente il UNITÀ pulsante.
  • Each press will cycle to the next available unit (e.g., in WC, Pa, kPa, mm WC, cm WC, psi).
  • L'unità selezionata verrà visualizzata sul display LCD.

6. Manutenzione

The Dwyer Series DM-2000 Differential Pressure Transmitter is designed for minimal maintenance. Regular checks ensure optimal performance and longevity.

  • Pulizia: Pulire l'esterno dell'unità con un panno morbido, damp panno. Non usare detergenti abrasivi o solventi.
  • Connessioni di pressione: Periodically inspect pressure tubing and connections for leaks or damage. Replace as necessary.
  • Ricalibrazione: While the digital zero and span simplify calibration, periodic recalibration by a qualified technician is recommended to maintain accuracy, especially in critical applications.
  • Controllo ambientale: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.

7. Risoluzione Dei Problemi

This section provides solutions to common issues encountered with the DM-2000 transmitter.

ProblemaPossibile causaSoluzione
No display/No outputNo power; Incorrect wiring; Faulty unitCheck power supply and connections; Verify wiring against diagram; Contact support if unit is faulty.
Letture impreciseNeeds zeroing; Needs span calibration; Leaks in pressure lines; Incorrect mounting orientationPerform zero adjustment; Perform span calibration (if applicable); Check pressure connections for leaks; Ensure vertical mounting.
Display shows "OVER" or "UNDER"Pressure exceeds/falls below rangeVerify applied pressure is within the transmitter's specified range.

8. Specifiche

ParametroValore
Numero di modelloDM-2002-LCD
MarcaDwyer
Compatibilità dei mediaAir and non-combustible, compatible gases
Segnale di uscita4-20 mA (standard)
CalibrazioneDigital push-button zero and span
Connessione elettricaScrew-type terminal block
Orientamento di montaggioVerticale
MaterialeVetro, Plastica
Peso dell'articolo1.1 libbre
Dimensioni del pacco5.9 x 5.3 x 2.9 pollici

9. Garanzia e supporto

9.1 Informazioni sulla garanzia

Dwyer Instruments, Inc. warrants its products to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. This warranty does not cover damage due to improper installation, misuse, abuse, or unauthorized repairs. For full warranty terms and conditions, please refer to the official Dwyer Instruments websito o contattare il loro servizio clienti.

9.2 Supporto tecnico

For technical assistance, troubleshooting beyond this manual, or to inquire about repairs and replacement parts, please contact Dwyer Instruments customer support.

  • Produttore: Strumenti Dwyer
  • Websito: www.dwyer-inst.com (Exampil collegamento (il collegamento effettivo potrebbe variare)
  • Informazioni sui contatti: Fare riferimento al produttore website for the most current contact details, including phone numbers and email addresses.

© 2024 Dwyer Instruments. All rights reserved.

Il presente manuale è fornito solo a scopo informativo. Le specifiche sono soggette a modifiche senza preavviso.

Documenti correlati - DM-2002-LCD

Preview Trasmettitore di pressione differenziale Dwyer Series DM DigiMag: specifiche e istruzioni
Guida completa al trasmettitore di pressione differenziale Dwyer Series DM DigiMag, che include specifiche, installazione, funzionamento e calibrazione. Le caratteristiche includono zero e span digitali a pulsante, display LCD e uscita 4-20 mA.
Preview Guida rapida al trasmettitore di pressione differenziale Dwyer serie DM DigiMag
Guida rapida per il trasmettitore di pressione differenziale Dwyer Series DM DigiMag, che fornisce informazioni essenziali per il montaggio, il cablaggio e la calibrazione.
Preview Trasmettitore di pressione differenziale Dwyer serie 616W: specifiche, installazione e funzionamento
Guida completa al trasmettitore di pressione differenziale Dwyer serie 616W, che comprende specifiche, procedure di installazione, collegamenti elettrici (uscite 4-20 mA e 0-5/0-10 V), calibrazione e risoluzione dei problemi.
Preview Trasmettitore di pressione differenziale Magnehelic serie 605 Dwyer: specifiche e guida all'installazione
Specifiche complete, istruzioni di installazione, collegamenti elettrici e guida alla regolazione della portata in uscita per il trasmettitore di pressione differenziale Magnehelic Dwyer Serie 605. Scopri di più sulle sue caratteristiche, sul montaggio e sulla calibrazione.
Preview Guida rapida all'installazione dell'inverter solare FIMER UNO-DM-TL-PLUS-Q
Una guida rapida all'installazione per la serie di inverter solari FIMER UNO-DM-TL-PLUS-Q, che copre modelli da 1.2 kW a 5.0 kW. Questa guida fornisce informazioni essenziali su etichette, simboli, componenti, procedure di installazione e specifiche tecniche.
Preview Guida all'installazione e alla configurazione di DeviceMaster
Guida completa per l'installazione e la configurazione della serie DeviceMaster di Comtrol, inclusi i modelli DM-Series, PRO, RTS e Serial Hub. ...

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.