1. Introduzione
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Dwyer Series DM-2000 Differential Pressure Transmitter. The DM-2000 series is designed to accurately sense the pressure of air and compatible gases, providing a standard 4-20 mA output signal. This device is ideal for various industrial and scientific applications requiring precise pressure measurement.
The DM-2000 housing is engineered for easy mounting, fitting into the same diameter cutout as a standard Magnehelic® gage. It features digital push-button zero and span adjustments for simplified calibration. Models with an optional 3.5 digit LCD display process and engineering units, with a single button allowing field selection of 4 to 6 engineering units depending on the range.
2. Informazioni sulla sicurezza
Per evitare lesioni personali e danni allo strumento, osservare sempre le seguenti precauzioni di sicurezza:
- Assicurarsi che l'alimentazione sia scollegata prima dell'installazione o della manutenzione.
- Only use the transmitter with air and non-combustible, compatible gases.
- Do not exceed the specified pressure range of the device.
- L'installazione e la manutenzione devono essere eseguite solo da personale qualificato.
- Proteggere il dispositivo da temperature estreme, umidità e ambienti corrosivi.
3. Prodotto finitoview

Figura 3.1: Davanti view of the Dwyer Series DM-2000 Differential Pressure Transmitter. The device features a circular black face with a digital LCD display showing "0.250 IN WC", the "DM-2000 Pressure Transmitter" model name, and two circular buttons labeled "ZERO" and "UNITS" at the bottom. The housing is light gray.
The Dwyer Series DM-2000 is a robust differential pressure transmitter designed for precise measurement. Key components include:
- Schermo LCD: (Optional) Provides real-time pressure readings and selected engineering units.
- Pulsante Zero: Used for digital zero adjustment.
- Pulsante Unità: Allows selection of various engineering units (e.g., in WC, Pa, kPa, mm WC, cm WC, psi).
- Connessioni di pressione: Integrated into the molded housing for quick and easy installation.
- Morsettiera elettrica: Screw-type for secure wiring.
4. Configurazione e installazione
4.1 Montaggio
The DM-2000 is designed for vertical mounting. Its housing is specifically sized to fit into the same diameter cutout as a standard Magnehelic® gage, simplifying replacement or new installations.
- Ensure the mounting surface is stable and free from vibrations.
- Mount the unit in a vertical orientation for optimal performance.
- Secure the transmitter using appropriate mounting hardware (not included).
4.2 collegamenti elettrici
The transmitter provides a standard 4-20 mA output signal. Connect the power supply and signal wires to the screw-type terminal block located on the unit.
- Refer to the wiring diagram provided with your specific model for correct polarity and connections.
- Use appropriate gauge wiring for the power supply and signal lines.
- Ensure all connections are secure to prevent intermittent operation.
4.3 Connessioni di pressione
Pressure connections are inherent to the glass-filled plastic molded housing. Connect the pressure tubing to the designated ports.
- Connect the higher pressure source to the 'High' port and the lower pressure source to the 'Low' port.
- Ensure tubing is free from kinks and leaks.
- Verify that the gases are non-combustible and compatible with the transmitter's materials.
5. Istruzioni per l'uso
5.1 Power On and Initial Reading
Once installed and wired, apply power to the transmitter. The LCD (if present) will illuminate and display the current differential pressure reading.
5.2 Regolazione dello zero
The DM-2000 features digital push-button zero adjustment. This simplifies calibration compared to traditional potentiometers.
- Ensure both pressure ports are open to atmospheric pressure or connected to the same pressure source (zero differential pressure).
- Premere e tenere premuto il tasto ZERO button until the display shows "0.000" or a similar indication of successful zeroing.
- Release the button. The transmitter is now zeroed.
5.3 Span Adjustment (Calibration)
Span adjustment is typically performed at the factory. However, digital span adjustment is available for field calibration.
- Apply a known, stable pressure equal to the full-scale range of the transmitter to the high-pressure port, with the low-pressure port at zero.
- Premere e tenere premuto il tasto UNITÀ button (or a combination as per specific model instructions) to enter span adjustment mode.
- Adjust the reading to match the applied full-scale pressure using the appropriate buttons (consult specific model manual for exact procedure).
- Salvare l'impostazione.
5.4 Changing Engineering Units (LCD Models)
For models equipped with an LCD, you can cycle through available engineering units.
- Premere momentaneamente il UNITÀ pulsante.
- Each press will cycle to the next available unit (e.g., in WC, Pa, kPa, mm WC, cm WC, psi).
- L'unità selezionata verrà visualizzata sul display LCD.
6. Manutenzione
The Dwyer Series DM-2000 Differential Pressure Transmitter is designed for minimal maintenance. Regular checks ensure optimal performance and longevity.
- Pulizia: Pulire l'esterno dell'unità con un panno morbido, damp panno. Non usare detergenti abrasivi o solventi.
- Connessioni di pressione: Periodically inspect pressure tubing and connections for leaks or damage. Replace as necessary.
- Ricalibrazione: While the digital zero and span simplify calibration, periodic recalibration by a qualified technician is recommended to maintain accuracy, especially in critical applications.
- Controllo ambientale: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.
7. Risoluzione Dei Problemi
This section provides solutions to common issues encountered with the DM-2000 transmitter.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| No display/No output | No power; Incorrect wiring; Faulty unit | Check power supply and connections; Verify wiring against diagram; Contact support if unit is faulty. |
| Letture imprecise | Needs zeroing; Needs span calibration; Leaks in pressure lines; Incorrect mounting orientation | Perform zero adjustment; Perform span calibration (if applicable); Check pressure connections for leaks; Ensure vertical mounting. |
| Display shows "OVER" or "UNDER" | Pressure exceeds/falls below range | Verify applied pressure is within the transmitter's specified range. |
8. Specifiche
| Parametro | Valore |
|---|---|
| Numero di modello | DM-2002-LCD |
| Marca | Dwyer |
| Compatibilità dei media | Air and non-combustible, compatible gases |
| Segnale di uscita | 4-20 mA (standard) |
| Calibrazione | Digital push-button zero and span |
| Connessione elettrica | Screw-type terminal block |
| Orientamento di montaggio | Verticale |
| Materiale | Vetro, Plastica |
| Peso dell'articolo | 1.1 libbre |
| Dimensioni del pacco | 5.9 x 5.3 x 2.9 pollici |
9. Garanzia e supporto
9.1 Informazioni sulla garanzia
Dwyer Instruments, Inc. warrants its products to be free from defects in material and workmanship for a period of one (1) year from the date of shipment. This warranty does not cover damage due to improper installation, misuse, abuse, or unauthorized repairs. For full warranty terms and conditions, please refer to the official Dwyer Instruments websito o contattare il loro servizio clienti.
9.2 Supporto tecnico
For technical assistance, troubleshooting beyond this manual, or to inquire about repairs and replacement parts, please contact Dwyer Instruments customer support.
- Produttore: Strumenti Dwyer
- Websito: www.dwyer-inst.com (Exampil collegamento (il collegamento effettivo potrebbe variare)
- Informazioni sui contatti: Fare riferimento al produttore website for the most current contact details, including phone numbers and email addresses.