This manual provides essential information for the safe and proper installation, operation, and maintenance of your Leviton 15 Amp, 125 Volt, Tamper-Resistant Duplex Receptacle (Model 25249-TFB). This commercial-grade, self-grounding receptacle features a straight blade design and a brass finish, engineered for demanding environments such as hotels, schools, hospitals, and commercial office buildings. It is designed to withstand rigorous use and offers enhanced safety features.

Informazioni sulla sicurezza

AVVERTIMENTO: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

Avvertenza sulla Proposta 65: Questo prodotto può contenere sostanze chimiche note allo Stato della California come causa di cancro, difetti congeniti o altri danni riproduttivi. Lavarsi le mani dopo la manipolazione.

  • Do not use this device with aluminum wiring. Use only with copper or copper-clad wire.
  • Assicurarsi che tutti i collegamenti siano ben saldi e sicuri per evitare il surriscaldamento.
  • This receptacle is tamper-resistant, designed to prevent insertion of foreign objects into the receptacle openings.
  • Do not exceed the specified electrical ratings of 15 Ampe 125 Volt.

Caratteristiche del prodotto

  • TampDesign resistente agli urti: Meets NEC 2020 article 406.12, providing enhanced safety by preventing the insertion of single objects into the receptacle openings.
  • Grado commerciale: Built to withstand demanding environments, ensuring durability and long-term performance.
  • Auto-messa a terra: Features an integral self-grounding clip for quick and easy installation into a properly grounded metal box.
  • Costruzione durevole: Thermoplastic receptacle face and body resist breakage.
  • Ready-To-Wire Unit: All-in-one design facilitates quick and easy installation.
Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish

Image: Leviton 25249-TFB Tamper-Resistant Duplex Receptacle, Brass Finish. This image shows the front view of the receptacle with its brass faceplate and two tampprese resistenti agli urti.

Configurazione e installazione

Installation of electrical devices should only be performed by qualified personnel. Always ensure power is disconnected before beginning any work.

  1. Spegnimento dell'alimentazione: Locate the circuit breaker or fuse that supplies power to the outlet where the receptacle will be installed. Turn it off and verify that power is off using a voltagetester.
  2. Rimuovere la vecchia presa (se applicabile): Carefully remove the existing wall plate and receptacle from the electrical box. Disconnect the wires, noting their connections (hot, neutral, ground).
  3. Preparare i cavi: Strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the circuit wires. Ensure wires are straight.
  4. Collegare i fili:
    • Collegare il caldo (nero) wire to the brass-colored screw terminal.
    • Collegare il neutro (bianco) wire to the silver-colored screw terminal.
    • Collegare il terra (rame verde o nudo) wire to the green screw terminal. This receptacle is self-grounding, meaning it will ground itself to a properly grounded metal box via its mounting strap.
    Assicurarsi che tutti i collegamenti dei cavi siano ben saldi e sicuri.
  5. Presa di montaggio: Carefully fold the wires into the electrical box, then insert the new receptacle and secure it with the mounting screws provided.
  6. Installa la piastra a muro: Attach the decorative wall plate (sold separately) over the receptacle.
  7. Ripristina alimentazione: Riattivare l'alimentazione tramite l'interruttore automatico o la scatola dei fusibili.
  8. Test: Test the receptacle with a known working appliance or receptacle tester to ensure proper function.
Leviton 25249-TFB Receptacle Back View

Immagine: Indietro view of the Leviton 25249-TFB receptacle, showing the screw terminals for wiring connections (hot, neutral, ground).

Istruzioni per l'uso

The Leviton 25249-TFB Tamper-Resistant Duplex Receptacle operates like a standard electrical outlet, with added safety features.

  • Collegamento: Insert the plug of your appliance or device firmly into one of the two receptacle openings. The tamper-resistant shutters may require slightly more force to open than a traditional receptacle. Ensure both prongs are inserted simultaneously and evenly.
  • Scollegamento: Grasp the plug and pull it straight out from the receptacle. Do not pull by the cord.
  • Capacità di carico: Do not overload the receptacle. The total current drawn by all connected devices should not exceed 15 Amps.

Manutenzione

The Leviton 25249-TFB receptacle requires minimal maintenance.

  • Pulizia: To clean the receptacle face, ensure power is off at the circuit breaker. Use a soft, damp panno. Non usare detergenti abrasivi o solventi.
  • Ispezione: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and have the receptacle inspected and replaced by a qualified electrician.
  • Considerazioni ambientali: While durable, avoid exposing the receptacle to excessive moisture or extreme temperatures beyond its operational specifications.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Nessun potere alla presa.Interruttore automatico scattato o fusibile bruciato. Collegamento elettrico allentato.Check and reset the circuit breaker or replace the fuse. If problem persists, turn off power and check wiring connections. Consult an electrician if necessary.
Plug does not insert easily.Tamper-resistant shutters are engaged.Ensure both prongs of the plug are aligned and inserted simultaneously and firmly. Do not force the plug.
Il contenitore è caldo.Overloaded circuit. Loose wiring connection.Unplug some devices to reduce load. Turn off power and check wiring connections. If warmth persists, consult an electrician immediately.

Specifiche

  • Modello: 25249-TFB
  • Ampera: 15 Amps
  • Voltage: 125 Volt
  • Configurazione: 5-15R
  • Numero di poli: 2
  • Numero di fili: 3
  • Messa a terra: Automessa a terra
  • Materiale: Nylon (body), Brass (finish)
  • Colore: Finitura in ottone
  • Standard e certificazioni: UL 498, CSA C22.2, NOM 057 Approved
  • Totale prese di corrente: 2

Garanzia e supporto

Garanzia: This Leviton product is backed by a 10-Year Limited Warranty. For detailed warranty terms and conditions, please refer to the official Leviton websito o contattare l'assistenza clienti.

Assistenza clienti: For technical assistance, troubleshooting, or warranty claims, please visit the official Leviton website or contact their customer service department. Contact information can typically be found on the product packaging or the Leviton websito.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.