PHILIPS ICN-2S28-N

Philips ICN-2S28-N Centium Electronic Ballast Instruction Manual

Model: ICN-2S28-N

1. Okwu mmalite

This manual provides detailed instructions for the safe installation, operation, and maintenance of your Philips ICN-2S28-N Centium Electronic Ballast. This ballast is designed for use with two F28T5, F21T5, or F14T5 fluorescent lamps, and can also operate single lamps. Please read this manual thoroughly before installation and retain it for future reference.

2. Ozi nchekwa

Ịdọ aka ná ntị: Risk of electric shock. Installation should be performed by a qualified electrician in accordance with all national and local electrical codes. Disconnect power at the circuit breaker before installation or servicing.

  • Gbaa mbọ hụ na ọkọnọ ọkụ voltage matches the ballast's rated voltage (120V ma ọ bụ 277V).
  • The ballast case must be properly grounded.
  • Ugwu lamps within 1/4 inch of a grounded metal reflector.
  • Oke voltage for RED-BLUE leads is 500 Vrms.
  • Insulate YELLOW leads for 600V.
  • Only use rapid-start sockets with this ballast.
  • Do not modify the ballast or its wiring.
  • This ballast is a Semi-Conducteur, High Power Factor, Class P, Sound Rated A, Type 1 Outdoor, with Inherent Thermal Protection. It contains no PCB's.

3. Ihe ngwugwu

Chọpụta na akụrụngwa niile dị tupu ịmalite nrụnye:

  • 1 x Philips ICN-2S28-N Centium Electronic Ballast
Philips ICN-2S28-N Centium Electronic Ballast with integrated wiring

Image 1: Philips ICN-2S28-N Centium Electronic Ballast with its integrated wiring.

4. Ntọala & nwụnye

Follow these steps for proper installation of the ballast:

  1. Kwụpụ ike: Before starting any work, ensure the main power supply to the fixture is turned off at the circuit breaker.
  2. Mount the Ballast: Securely mount the Philips ICN-2S28-N ballast within the fixture. Ensure the ballast case is grounded.
  3. Njikọ waya: Refer to the wiring diagram on the ballast label and the instructions below.
Close-up of Philips ICN-2S28-N ballast label showing wiring diagram and specifications

Foto 2: Zuru ezu view of the ballast label, including wiring diagram and technical specifications.

Nkọwa eserese waya:

  • Input Power (120V or 277V):
    • Jikọọ OJI wire to the Line (L) input.
    • Jikọọ Ọcha wire to the Neutral (N) input.
  • Lamp Connections (for 2 Lamps):
    • Jikọọ Acha anụnụ anụnụ wires to one end of each lamp.
    • Jikọọ Uhie wires to the other end of each lamp.
    • Jikọọ ODO wires to the remaining terminals of the lamps.
  • Nda ala: Ensure the ballast case is properly grounded to the fixture's metal housing.

Ihe ndetu ndị dị mkpa:

  • This ballast is compatible with (2) F28T5, (2) F21T5, and (2) F14T5 lamps. It also works for single lamps.
  • Ugwu lamps within 1/4 inch of a grounded metal reflector for optimal performance and safety.
  • Insulate any unused YELLOW leads for 600V.
  • Only use rapid-start sockets.
Philips ICN-2S28-N ballast with wires spread out, showing color coding

Image 3: The ballast with its color-coded wires clearly visible for connection.

5. Ọrụ

Once the Philips ICN-2S28-N Centium Electronic Ballast is correctly installed and wired, operation is straightforward:

  1. After completing the installation, restore power to the circuit at the breaker.
  2. Turn on the light switch connected to the fixture. The ballast will automatically ignite and regulate the power to the fluorescent lamps.
  3. The ballast is designed for programmed start, ensuring optimal lamp ndu.

6. Nlekọta

The Philips ICN-2S28-N Centium Electronic Ballast is designed for long-term, reliable operation with minimal maintenance. However, periodic checks can help ensure continued performance:

  • Ịkwụsị ike: Kwụpụ ọkụ eletrik mgbe niile tupu ị rụọ ọrụ mmezi ma ọ bụ nyocha ọ bụla.
  • Nhicha: Keep the ballast and fixture free from dust and debris to ensure proper heat dissipation. Use a dry, soft cloth for cleaning.
  • Nyocha waya: Periodically inspect wiring connections for any signs of wear, fraying, or loose connections. Ensure all connections remain secure.
  • Lamp Ndochi: Mgbe dochie lamps, ensure they are of the correct type and wattage as specified for this ballast (F28T5, F21T5, F14T5).
  • Ọnọdụ gburugburu: Ensure the ballast operates within its specified temperature range and environmental conditions (Type 1 Outdoor).

7. Nchọpụta nsogbu

If your fluorescent fixture is not operating correctly, consult the following troubleshooting guide:

NsogbuIhe nwere ike imeNgwọta
Lamps adịghị ọkụ.Enweghị ikike na ngwa.
Wiring na -ezighi ezi.
Emejọrọ lamps.
Ballast adịghị mma.
Lelee ihe mgbawa sekit na mgba ọkụ mgbidi.
Verify all wiring connections against the diagram.
Dochie lamps with new ones of the correct type.
Ọ bụrụ lamps are new and wiring is correct, replace the ballast.
Lamps flicker or dim.Njikọ waya rụrụ arụ.
ezighi ezi lamp ụdị.
Ịka nká lamps.
Ballast nearing end of life.
Lelee ma chekwaa njikọ waya niile.
Gbaa mbọ hụ na ezi lamp types (F28T5, F21T5, F14T5) are used.
Dochie lamps.
Consider replacing the ballast.
Ballast makes humming noise.Normal operation (slight hum).
Nkwalite rụrụ arụ.
ekpo oke ọkụ.
A slight hum is normal for some ballasts. Ensure ballast is securely mounted.
Check for proper ventilation and ensure ballast is not covered. If hum is loud or new, inspect for issues.

If troubleshooting steps do not resolve the issue, contact a qualified electrician or Philips customer support.

8. Nkọwapụta

Below are the technical specifications for the Philips ICN-2S28-N Centium Electronic Ballast:

  • Nọmba nlereanya: ICN-2S28-N
  • Akara: PHILIPS (Advance Ballast)
  • Ntinye Voltage: 120V / 277V
  • Dakọtara Lamps: (2) F28T5, (2) F21T5, (2) F14T5 (also works for single lamps)
  • Wattage: 28 watts (for F28T5 lamps)
  • Ụdị isi iyi ọkụ: Fluorescent
  • Isi mmalite ike: Igwe ọkụ eletrik
  • Ihe: Plastic
  • Agba: Nwa
  • Ụdị: Rectangular
  • Imecha Type: Nwa
  • Ụdị nkwụnye: Ugwu Akwa
  • Ibu ihe: 9.6 ounces
  • Akụkụ ihe (L x W x H): 9.5" x 1.25" x 1"
  • UPC: 781087080726
  • Asambodo: UL Listed 704G, CSA (NRTL/C)
  • Atụmatụ: IntelliVolt (120V to 277V 50/60Hz), Programmed Start, High Power Factor, Class P, Sound Rated A, Type 1 Outdoor, Inherent Thermal Protection, No PCB's.
Akụkụ view of Philips ICN-2S28-N ballast showing dimensions and mounting holes

Foto 4: Akụkụ view of the ballast, illustrating its compact dimensions and mounting points.

9. Akwụkwọ ikike & Nkwado

This Philips ICN-2S28-N Centium Electronic Ballast comes with a manufacturer's warranty. For specific warranty details, please refer to the documentation included with your purchase or contact Philips customer support.

For technical assistance or support, please contact Philips directly. Technical information is often available via their official websaịtị ma ọ bụ site n'ịkpọ ahịrị nkwado ha.

  • Onye nrụpụta: Advance Ballast (a Philips company)
  • Ozi nka na ụzụ: 1.800.372.3331 (as seen on product label)
  • Nkwado n'ịntanetị: Visit the official Philips website for product support and resources.

© 2024 PHILIPS. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.