Honeywell logo

INSTALLATION INSTRUCTIONS FOR THE
MICROSWITCH GLS DIN SERIES
GLOBAL LIMIT SWITCH

81501
Issue 6

Honeywell 81501 Micro Switch GLS DIN Series - icon

Ui 600V ac
Ui 300V dc
UL 50041
EN60947-5-1
EN45545-2 HL 3 (GLA & GLF Series switches only)
EN61373 (GLA Series switches only)

warning 2 WARNING

IMPROPER INSTALLATION

  • Consult with local safety agencies and their requirements when designing a machine-control link, interface, and all control elements that affect safety.
  • Strictly adhere to all installation instructions.

Failure to comply with these instructions could result in death or serious injury.

MOUNT, WIRE, AND SEAL THE SWITCH
warning 2 WARNING
IMPROPER OPERATION

  • Ensure the switch actuator achieves sufficient travel for the positive opening of normally closed (NC) contacts to occur.
    Failure to comply with these instructions could result in death or serious injury.
  1. Refer to:
    • Page 5 for adjustments.
    • Pages 9 to 18 for specific travel distances for each switch code, and specifications.
    • Page 5 proper application of limit switches, and switch mounting dimensions.
  2. Perform adjustments (if desired):
    • Head orientation, page 5.
    • Actuation direction (Figure 2, page 5).
    • Side rotary switches with 90* positive drive levers (catalog listings ending in AlA, A1B, A5A, A5B) (Figure 3):
    – Ensure flats of switch shaft engage a groove in actuator lever.
    – Tighten locking screw (A) until tab (B) no longer moves.
  3. Mount switch using four M5 or #10 screws. Torque screws to 4,9 Nm to 5,9 Nm [43 in-lb to 52 in-lb].
  4. Remove screws on the cover plate.
  5. Connect stranded wire (0,75 mm2 to 2,5 mm2, 18-14 AWG) or solid wire (0,75 mm2 to 1,5 mm2, 18-16 AWG) to connector terminals (use 90 *C wire when ambient temperature is over 75 *C). Torque switch terminal screws to 0,8 Nm to 1,0 Nm [7 in-lb to 9 in-lb]. Wire strip length should be 7,3 mm [0.29 in] max.
  6. Seal conduit opening according to instructions in PK 80112.
  7. Reassemble cover plate, and torque cover screws to 0,5 Nm [4.4 in-lb].

MICROSWITCH GLS DIN LIMIT SWITCH
GLA, GLB, GLF, GLG, GLH SERIES

FIELD ADJUSTABLE HEAD
FIELD VERSTELLBAREM KOPF
CAMPO TESTA REGOLABILE

Honeywell 81501 Micro Switch GLS DIN Series - FIELD ADJUSTABLE HEAD

Honeywell 81501 Micro Switch GLS DIN Series - TERMS

TERMS BEDINGUNGEN TARIFFE

Contact Closed
Contact Open
Differential Travel
Free Position
Operating Position 1
Positive Opening 1 to IEC 947-5-1
Differential Travel 1
Over Travel
Maximum Operating Force
Maximum Disconnect Force

FIGURE 1.
READING OPERATING SPECIFICATIONS

Honeywell 81501 Micro Switch GLS DIN Series - FIGURE 1

PRODUCT NOMENCLATURE

Honeywell 81501 Micro Switch GLS DIN Series - PRODUCT NOMENCLATURE

Figure 2.
Fixed Lever, Side Rotary Switch – Non-plug-in Body Style, GLZ51 lever, and GLA body

Honeywell 81501 Micro Switch GLS DIN Series - Figure 2

LEVER (catalog listing) ROLLER MATL X DIM Y DIM Z DIM
GLZ51A NYLON 19,1
.75
55,9
2.20
6,4
.25
GLZ51B STEEL 19,1
75
55,9
2.20
6,4
.25
GLZ51C NYLON 24,5
1.00
59,1
2.33
12,7
.50
GLZ51Y RUBBER 50,0
1.97
66,1
2.60
10,0
.39
GLZ51T STAINLESS
STEEL
19.1
.75
56.8
2.24
8.8
.345

Figure 3.
Fixed Lever, Side Rotary Switch – Plug-in Body Style, GLZ51 lever, and GLB body

Honeywell 81501 Micro Switch GLS DIN Series - Figure 3

Figure 4.
Adjustable Lever Dimensions, GLZ52

Honeywell 81501 Micro Switch GLS DIN Series - Figure 4

LEVER ROLLER MATL X DIM Y DIM Z DIM
GLZ52A NYLON 19,1
.75
65,9
2.59
6,4
.25
GLZ52B STEEL 19,1
.75
65,9
2.59
6,4
.25
GLZ52D NYLON 38,1
1.5
65,9
2.59
6,4
.25
GLZ52E NYLON 19,1
.75
79,37
3.125
33,07
1.300
GLZ52W RUBBER 40 0
1.6
71,5
2.81
12,7
.5
GLZ52Y RUBBER 50 0
1.97
68,8
2.71
10,0
.39

Figure 5.
Aluminum Rod Lever Dimensions, GLZ54

Honeywell 81501 Micro Switch GLS DIN Series - Figure 5

Notes:

  • The free position, operate point, over-travel, and pre-travel all to EN 50041
  • Operating characteristics apply to counterclockwise (CCW) and clockwise (CW) actuation
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

Honeywell 81501 Micro Switch GLS DIN Series - Release

FIGURE 6. HEAD CODE: A
SIDE ROTARY ANGULAR OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 6

Notes:

  • Cam travel for adjustable lever applies when lever is adjusted to 38,1 mm [1.5 in]
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

Honeywell 81501 Micro Switch GLS DIN Series - lever applies

FIGURE 7. HEAD CODE: A • SIDE ROTARY CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 7

Honeywell 81501 Micro Switch GLS DIN Series - Operate point

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 8. HEAD CODE: B
PIN PLUNGER OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 8

Honeywell 81501 Micro Switch GLS DIN Series - Roller

Notes:

  • Free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 9. HEAD CODE: C
TOP ROLLER PLUNGER PIN ACTUATION OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 9

Honeywell 81501 Micro Switch GLS DIN Series - Differential

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 10. HEAD CODE: C
ROLLER PLUNGER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 10

Honeywell 81501 Micro Switch GLS DIN Series - read operating

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 11. HEAD CODE: D
TOP ROLLER LEVER PIN ACTUATION OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 11

Honeywell 81501 Micro Switch GLS DIN Series - 50041

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 12. HEAD CODE: D
TOP ROLLER LEVER CAM ACTUATION PER EN50041 OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 12

Head Code: E • WOBBLE AND CAT WHISKER ACTUATOR DIMENSIONS

Figure 13. Coil Actuator

Honeywell 81501 Micro Switch GLS DIN Series - Figure 13

Figure 14. Plastic Rod and Flexible Cable

Honeywell 81501 Micro Switch GLS DIN Series - Figure 14

Figure 15. Cat Whisker Wobbles

Honeywell 81501 Micro Switch GLS DIN Series - Figure 15

Honeywell 81501 Micro Switch GLS DIN Series - 50041 parts

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 16. HEAD CODE: E
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 16

Honeywell 81501 Micro Switch GLS DIN Series - characteristics

Notes:

  • The free position, operate point, overtravel, and pretravel all to EN50041
  • Refer to page 5 for instructions on how to read operating characteristics and specifications

FIGURE 17. HEAD CODE: K
WOBBLE STICK ANGULAR ACTUATION OPERATING CHARACTERISTICS

Honeywell 81501 Micro Switch GLS DIN Series - Figure 17

WARRANTY/REMEDY

Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to
otherwise by Honeywell in writing; please refer to your order acknowledgment or consult your local sales office for specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective.
The foregoing is the buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use.

FOR MORE INFORMATION
Honeywell Advanced Sensing Technologies services its customers through a worldwide network of sales offices and distributors. For application assistance, current specifications, pricing or the nearest Authorized Distributor,

Honeywell logo

visit our website or call:
USA/Canada +1 302 613 4491
Latin America +1 305 805 8188
Europe +44 1344 238258
Japan +81 (0) 3-6730-7152
Singapore +65 6355 2828
Greater China +86 4006396841

Honeywell
Advanced Sensing Technologies
830 East Arapaho Road
Richardson, TX 75081
sps.honeywell.com/ast

PK 81501-6-EN | 6 | 06/21
© 2021 Honeywell International Inc. All rights reserved.

Documents / Resources

Honeywell 81501 Micro Switch GLS DIN Series [pdf] Instruction Manual
81501 Micro Switch GLS DIN Series, 81501, Micro Switch GLS DIN Series

Leave a comment