User Manual for MOXA models including: UC-3400A, UC-3400A Series Arm Based Computers, Arm Based Computers, Based Computers

UC-3400A Series Hardware User Manual

Aring Yeh Moxa Inc.

UC-3400A Series Hardware User Manual

Moxa Uc 3400a Series Hardware Manual V1.0 download

UC-3424A-T-LTE | Moxa Moxa | IIoTzone.com


File Info : application/pdf, 18 Pages, 3.65MB

PDF preview unavailable. Download the PDF instead.

moxa-uc-3400a-series-hardware-manual-v1.0
UC-3400A Series Hardware User Manual
Version 1.0, February 2025 www.moxa.com/products
© 2025 Moxa Inc. All rights reserved.

UC-3400A Series Hardware User Manual
The software described in this manual is furnished under a license agreement and may be used only in accordance with the terms of that agreement.
Copyright Notice
© 2025 Moxa Inc. All rights reserved.
Trademarks
The MOXA logo is a registered trademark of Moxa Inc. All other trademarks or registered marks in this manual belong to their respective manufacturers.
Disclaimer
· Information in this document is subject to change without notice and does not represent a commitment on the part of Moxa.
· Moxa provides this document as is, without warranty of any kind, either expressed or implied, including, but not limited to, its particular purpose. Moxa reserves the right to make improvements and/or changes to this manual, or to the products and/or the programs described in this manual, at any time.
· Information provided in this manual is intended to be accurate and reliable. However, Moxa assumes no responsibility for its use, or for any infringements on the rights of third parties that may result from its use.
· This product might include unintentional technical or typographical errors. Changes are periodically made to the information herein to correct such errors, and these changes are incorporated into new editions of the publication.
Technical Support Contact Information
www.moxa.com/support

Table of Contents
1. Introduction .........................................................................................................................................4 Overview .............................................................................................................................................. 4 Package Checklist ..................................................................................................................................4 Hardware Specifications .........................................................................................................................4
2. Hardware Introduction .........................................................................................................................5 Appearance........................................................................................................................................... 5 Dimensions ...........................................................................................................................................7 LED Indicators.......................................................................................................................................8 Real-time Clock .....................................................................................................................................9 Placement Options .................................................................................................................................9
3. Hardware Connection Description ......................................................................................................12 Wiring Requirements ............................................................................................................................ 12 Connector Description .......................................................................................................................... 13 Power Connector .......................................................................................................................... 13 Grounding the UC-3400A .............................................................................................................. 13 Ethernet Port ............................................................................................................................... 14 Serial Port ................................................................................................................................... 14 CAN Port ..................................................................................................................................... 14 SIM Card Slot .............................................................................................................................. 15 Console Port ................................................................................................................................ 15 microSD Slot ............................................................................................................................... 16 USB Port ..................................................................................................................................... 16 Connecting Antennas .................................................................................................................... 16
A. Regulatory Approval Statements ........................................................................................................18

1. Introduction
Overview
Moxa's UC-3400A Series computers can be used as edge gateways in the field for data pre-processing and transmission, as well as for other embedded data-acquisition applications. The series includes a diverse set of models, each supporting different wireless options and protocols. The UC-3400A's advanced heat-dissipation design makes it suitable for use in temperatures ranging from 40 to 70°C. In fact, the Wi-Fi and LTE connections can be used simultaneously in both cold and hot environments, allowing you to maximize data pre-processing and transmission capabilities of your applications in harsh operating environments. The UC-3400A comes equipped with Moxa Industrial Linux, a high-performance industrial-grade Linux distribution with long-term support that is developed by Moxa.
Package Checklist
Before installing the UC-3400A, verify that the package contains the following items: · 1 x UC-3400A Arm-based computer · 1 x Quick installation guide (printed) · 1 x Warranty card
NOTE
Notify your sales representative if any of the above items are missing or damaged.
Hardware Specifications
NOTE
The latest specifications for Moxa's products can be found at https://www.moxa.com.

UC-3400A Series Hardware User Manual

4

2. Hardware Introduction
The UC-3400A embedded computers are compact and rugged making them suitable for industrial applications. The LED indicators help in monitoring performance and troubleshooting issues. The multiple ports provided on the computer can be used to connect to a variety of devices. The UC-3400A comes with a reliable and stable hardware platform that lets you devote the bulk of your time to application development. In this chapter, we provide basic information about the embedded computer's hardware and its various components.
Appearance
UC-3420A-T-LTE
UC-3424A-T-LTE

UC-3400A Series Hardware User Manual

5

UC-3430A-T-LTE-WiFi UC-3434A-T-LTE-WiFi

UC-3400A Series Hardware User Manual

6

Dimensions

UC-3400A Series Hardware User Manual

7

LED Indicators

Refer to the following table for information about each LED.

LED Name PWR
READY
SIM
USR LAN1/ LAN2
(Wi-Fi Signal Strength)
(Cellular Signal Strength) P1/P2 (Serial Port) P3/P4 (CAN Port)

Color

Status

Function

Green

Steady on

Power is on

Off

Power is off

Green

Steady on Blinking

System is ready for use System is booting up

Red

Steady on

System initialization failed

Off

System is still in the bootloader stage, kernel not

up yet

SIM card inserted

Green

Steady on

AND

SIM2 is the active slot

SIM card inserted

Yellow

Steady on

AND

SIM1 is the active slot

Off

SIM card not detected

Green/ Yellow

Steady on/blinking/off

User programmable

Green

Steady Blinking

10/100 Mbps link established Receiving or transmitting data

Yellow

Steady Blinking

1000 Mbps link established Receiving or transmitting data

Off

Ethernet port is not active

3 LEDs Steady on Signal strength at 61% to 100%

Green

2 LEDs Steady on Signal strength at 41% to 60% 1 LED Steady on Signal strength at 21% to 40%

1 LED Blinking

Signal strength at 0% to 20%

Off

No signal

*For UC-3420 and UC-3424 models, the WI-FI signal strength LEDs are user

programmable.

3 LEDs Steady on Signal is good

Green

2 LEDs Steady on Signal is moderate/ok 1 LED Steady on Signal is poor

Off

No signal

Green

Blinking

Serial port is transmitting data

Yellow

Blinking

Serial port is receiving data

Off

Serial port is not active

Light Yellow Blinking

CAN port is transmitting data

Yellow

Blinking

CAN port is receiving data

Off

CAN port is not active

UC-3400A Series Hardware User Manual

8

Real-time Clock
The real-time clock in the UC-3400A is powered by a lithium battery. We strongly recommend that you do not replace the lithium battery without the help of a Moxa support engineer. If you need to change the battery, contact the Moxa RMA service team.
WARNING
There is a risk of explosion if the battery is replaced with an incorrect battery type. Dispose of used batteries according to the manufacturer's instructions.
Placement Options
The UC-3400A computer can be mounted on to a DIN rail or on a wall. The DIN-rail mounting kit is attached by default. To order a wall-mounting kit, contact a Moxa sales representative.
DIN-rail Mounting
To mount the UC-3400A on to a DIN rail, do the following: 1. Pull down the slider of the DIN-rail bracket located at the back of the unit 2. Insert the top of the DIN rail into the slot just below the upper hook of the DIN-rail bracket. 3. Latch the unit firmly on to the DIN rail as shown in the illustrations below. 4. Once the computer is mounted properly, you will hear a click and the slider will rebound back into place
automatically.

UC-3400A Series Hardware User Manual

9

Wall Mounting (optional)
The UC-3400A can also be wall mounted. The wall-mounting kit needs to be purchased separately. Refer to the datasheet for information on the wall-mounting kit to be purchased. For the mounting dimensions, refer to the figure below:

To mount the computer on to a wall, do the following:

1. Attach two wall-mounting brackets with four M3 x 5 mm screws on the right side panel of the computer as indicated in the figure.

2. Use another four screws to fasten the computer on to a wall or a cabinet.

Recommended Torque: 4.5±0.5kgf-cm

UC-3400A Series Hardware User Manual

10

The additional four screws are not included in the wall-mounting kit and must be purchased separately. Refer to the following specifications for the additional screws to be purchased.
Head Type: Pan/Doom Head Diameter: 5.2 mm < Outer Diameter (OD) < 7.0 mm Length: > 6 mm Thread Size: M3 x 0.5P
3. Push the computer to the left to ensure the computer is securely fixed to the mounting surface.

UC-3400A Series Hardware User Manual

11

3. Hardware Connection Description
This section describes how to connect the UC-3400A to a network and connect various devices to the UC3400A as well as how to power it.
Wiring Requirements
You must pay attention to the following common safety precautions before proceeding with the installation of any electronic device: · Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must
cross, make sure the wires are perpendicular at the intersection point.
NOTE
Do not run the wires for signal or communication and power wiring in the same wire conduit. To avoid interference, wires with different signal characteristics should be routed separately.
· You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
· Keep input wiring and output wiring separate. · We strongly advise that you label wiring to all devices in the system for easy identification.
ATTENTION
Safety First! Be sure to disconnect the power cord before installing and/or wiring the computer. Electrical Current Caution! Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes dictating the maximum current allowable for each wire size. If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your equipment. Temperature Caution! Be careful when handling the unit. When the unit is plugged in, the internal components generate heat, and consequently the outer casing may be hot to touch by hand.

UC-3400A Series Hardware User Manual

12

Connector Description

Power Connector

Connect the power jack to the terminal block located on the top panel, and then connect the power adapter to the power jack. Use a 12 to 24 AWG wire and secure the plug by screws with a minimum torque value 0.5 N-m (4.4253 lb-in).

After the power is connected, it takes about 10 to 30 seconds for the system to boot up. Once the system is ready, the READY LED will light up.
Attention
The wiring for the input terminal block must be done by a skilled person. The wire type should be copper (Cu).
ATTENTION
The product is intended to be supplied by a UL Listed Power Unit marked "L.P.S." (or "Limited Power Source") and rated 9 to 48 VDC, 1.2 A (min.), Tma = 70°C. If you need further assistance with purchasing the power source, contact Moxa for further information. If you are using a Class I adapter, the power cord must be connected to a socket-outlet with an earthing connection.
Grounding the UC-3400A
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). The grounding screw or GS (M4-type screw) is located on the top panel. When you connect to the GS wire, the noise is routed directly from the metal chassis to the ground point.

NOTE
The grounding wire must have a minimum diameter of 3.31 mm².

UC-3400A Series Hardware User Manual

13

Ethernet Port

The 10/100/1000 Mbps Ethernet port uses the RJ45 connector. The pin assignment of the port is shown below:

Pin 10/100 Mbps 1000 Mbps

1

ETx+

TRD(0)+

2

ETx-

TRD(0)-

3

ERx+

TRD(1)+

4

­

TRD(2)+

5

­

TRD(2)-

6

ERx-

TRD(1)-

7

­

TRD(3)+

8

­

­

Serial Port

The serial port uses the DB9 male connector. It can be configured by software for the RS-232, RS-422, or RS-485 mode. The pin assignment of the port is shown below:

Pin

RS-232

1

DCD

2

RxD

3

TxD

4

DTR

5

GND

6

DSR

7

TRS

8

CTS

9

­

RS-422 TxD-(A) TxD+(A) RxD+(B) RxD-(A)
GND ­ ­ ­ ­

RS-485 ­ ­
Data+(B) Data-(A)
GND ­ ­ ­ ­

CAN Port

The UC-3424A and UC-3434A models come with two CAN ports, which use the terminal block connector and are compatible with the CAN 2.0A/B standard.

UC-3400A Series Hardware User Manual

14

SIM Card Slot

The UC-3400A comes with a nano-SIM card slot, a console port, and a microSD slot on the front panel.

To install SIM cards, do the following:

1. Remove the screw on the slot cover. UC-3400A comes with a nano-SIM card slot.

2. Push the SIM card tray in and then pull it out to remove it.

ATTENTION
When the tray slot is open, ensure that LAN2 is not connected to the network.

3. The SIM card tray can install two SIM cards, one on each side of the tray.

4. Install the SIM card in SIM1 slot. Install the other SIM card in SIM2 on the other side of the tray.

5. Insert the tray into the SIM card slot and secure the cover to the slots. To remove the SIM cards, push the tray in before releasing it.

Console Port

The console port located on the left side of the SIM card slot is a RS-232 port that can connect to a 4-pin pin header cable. You can use this port for debugging or firmware upgrade.

Pin

Signal

1

TXD

2

RXD

3

­

4

GND

UC-3400A Series Hardware User Manual

15

microSD Slot
There is a microSD slot located above the SIM card slot. Insert the microSD card into the slot. To remove the card, push it in first and release it.
USB Port
The USB port is a type A USB 2.0 port, which can be used to connect to a type-A USB storage device.
NOTE
It is recommended that the peripheral devices installed should be placed at least 25 mm away from the UC-3400.
Connecting Antennas
The UC-3400A comes with antenna connectors for various interfaces.
Cellular
The UC-3400A models come with a built-in cellular module. Connect the antenna to the SMA connector with the cellular mark to enable the use of the cellular function.
GPS
The UC-3400A models come with a built-in GPS module. Connect the antenna to the SMA connector with the GPS mark to enable the use of the GPS function.

UC-3400A Series Hardware User Manual

16

Wi-Fi
The UC-3430A-T-LTE-WiFi and UC-3434A-T-LTE-WiFi models come with a built-in Wi-Fi module. Connect the antenna to the RP-SMA connector marked W2 to enable the use of the Wi-Fi function.
Bluetooth
The UC-3430A-T-LTE-WiFi and UC-3434A-T-LTE-WiFi models come with a built-in Bluetooth module. Connect the antenna to the RP-SMA W1 connector to enable the use of the Bluetooth function.
For additional details, refer to the UC-3400A Series datasheet.

UC-3400A Series Hardware User Manual

17

A. Regulatory Approval Statements
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class A: FCC Warning! This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the users will be required to correct the interference at their own expense.
European Community
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures.

UC-3400A Series Hardware User Manual

18



References

Aring Yeh Adobe PDF Library 24.5.96