Instruction Manual for acson models including: A5CM 15C Ceiling Cassette, A5CM 15C, Ceiling Cassette, Cassette

CEILING MOUNTED SERIES - Acson Malaysia

CEILING MOUNTED SERIES / P1 Acson Ceiling Cassette is equipped with R410A refrigerant gas. R410A refrigerant is a near-azeotropic mixture of 50% of R32 and 50% of R125 which contributes zero Ozone

CEILING MOUNTED SERIES


File Info : application/pdf, 8 Pages, 983.64KB

PDF preview unavailable. Download the PDF instead.

CAT-A5CM-2103
CEILING MOUNTED SERIES
Iconic

Common Installation Places

Model: A5CM 15C - 62C Nominal Cooling Capacity: 1.27kW ~ 6.41kW 12,500 BTU/h ~ 55,000 BTU/h
Acson Ceiling Mounted Ecocool Series provides magnificent cooling comfort with a wide range of airthrow range and cost savvy on mind. Desired cooling comfort can be achieved rapidly through excellent air distribution. Reliable yet durable to deliver maximun air flow to the surroundings.

1. Restaurant and Cafe Shop
Ensuring every corners will be cooled and optimun cooling comfort will be achived especially for social gathering purposes. Optimun cooling temperature is vital to ensure customers's comfort during social gathering.

Acson Ceiling Cassette is equipped with R410A refrigerant gas. R410A refrigerant is a near-azeotropic mixture of 50% of R32 and 50% of R125 which contributes zero Ozone Depletion Potential (ODP). It is a greener choice compared to R22 refrigerant to preserve global climate changes. At Acson, we commit to bring the best air solutions by taking in environmentally-friendly consideration.

R22
refrigerant contributes 0.05 ODP

R410A
refrigerant contributes
0 ODP

CEILING MOUNTED SERIES / P1

2. Lobby
Hot air from outside easily circulated inside lobby with the frequent entry from outside. Acson Ceiling Mounted is able to maintain desired temperature with consistent optimun air distribution by motorized louver. A powerful airflow allows distribution of air from the upper and lower air outlets.
3. School Hall
Feel the fast cooling and powerful airflow especially at the fully-occupied hall. Hot air tends to stagnated at in fully-occupied hall which will bring discomfort and concentration will be disrupted. Acson Ceiling Mounted is able to provide powerful airfow which aids the circulation of the cool air.

Features of Ceiling Mounted

Aesthetically Compact Design
Acson Ceiling Mounted Series has slim compact design for economical and space saving installation. The unit's installation can be easily done without ceiling hacking.

Powerful Airflow and Instant Cooling
Instant cooling and concentrated air flow will be distributed evenly across the room. Desired cooling comfort will be continously mantained to keep the occupants comfortable and relax

Ceiling & Floor Installation Option
Specially designed to provide versatility installation for the user. The user can choose whether ceiling mounted installation or floor mounted installation if there is no space at ceiling installation.
*Applicable models for floor installation: A5CMY40E and A5CMY50E

Durable and Accessible Saranet Filter
The anti fungus can trap filter duct particles in the air , thus providing fresh and healthy environment for the occupants. Easy maintenance and cleaning can be possibly done as the filter can be acccessed easily and can be cleaned by using water only. The filter can be repeately used after cleaning to avoid regular change.

Optional Accessories
Acson Easi Flo Series drainage pump can be requested as optional to drain the condensate water from the unit. We offer a peace of mind for the user as our Acson Easi Flo Series drainage pump comply with international electrical appliances safety standards.

Easi-Flo II

Easi-Flo 22

Easi-Flo 33

CEILING MOUNTED SERIES / P2

Easi-Flo 55

Power of Inverter
Acson Inverter technology controls the compressor's speed accordingly to continuously regulate the room's temperature. The compressor is not constantly running at full power, as the system utilizes a controlled compressor that works at variable speed settings. This consequently lead to much more energy-efficient and environmentally-friendly option than traditional AC.

ENERGY SAVINGS

High Efficiency Motors
Intelligent Control System

High Efficiency Air-cond

Acson R410A Inverter ultilizes hermetic swing compressor. It's precise structure and mechanical movement help to reduce friction and vibration compared to conventional rotary compressor. This reduces refrigerant leakage and ensures maximun capacity is achieved.
Swing Brushing Refrigerant Gas

Piston Incorporated Blade and Roller

Comfort Control
Non-Inverter System uses a fixed-speed compressor, which cycles the unit on and off once the room dips below desired temperature. This can lead to unpleasant temperature swings as the system need to mantain maintain a constant temperature. Inverter's compressor speed is controlled at variable speed which provides a more precise, on-demand approach to temperature control.

Temperature Fluctuation During Cooling Operation

Not Cool

Small Temp. Difference Non-inverter

Temp.

Set temp.

Comfortable

Inverter

Too Cool

Time

Running Current Gradual Increase of
Inverter compressor rotation

Inverter · Low starting current · Smooth operation
Non-inverter · High starting current · Frequent on/off cycle
Hours of Operation

NonInverter

High starting torque to start compressor from stationary compressor

Energy Saving
From an energy perspective, constantly turn on and off compressor can be a costly endeavor.
While inverter system is always on, running at a fraction of full speed is far more efficient in the long run. It's estimated that non- inverter system systems draws higher power on start-up than inverter system.

CEILING MOUNTED SERIES / P3

MY Acson, MY Control (Optional Accessory)
MY Acson now offers smart functionality to boost your smart home experience. With MY Acson, you can convieniently control and monitor air conditoner units at anywhere and anytime.Instead of running for the AC remote controller as soon as you reach home, you can enjoy a cool breeze with few taps on your smartphone now. *R410A CM Applicable Models: A5CM-C Series A5CMY- E Series (4.0HP & 5.0HP), NS Splitter is required.

Besides hassle- free from finding remote controller, all you need are MY Acson and your smartphone to improve your lifestyle, AC Usage, comfort and smart home experience.

MY Acson App
A single swipe on the phone application which designed with simple control user interface. MY Acson is currently available for both Android & IOS system.

Acson Wifi Adapter, AWM01A01

MY Acson App

MY ACSON

MY Complete Control

MY Convenience

MY Comfort

· Setting different modes to suit your needs and comfort.
· Controlling fan speed, air flow direction & temperature settings
· Controlling the Zoning System

· Set 7-day schedules & timers that adjust AC according to your lifestyle
· Control every AC unit from your couch no need to go racing room-to-room changing settings
· Guest sharing option - possible to be both hospitable and safe

· Pre-cool your room whilst still in the workplace or office.
· Room is already pre-cooled according to your desired settings as you reach home.

Specification

Height (mm)

Dimension

Width (mm)

Depth (mm)

Wi-Fi Frequency

Network Configuration Out-of-home Control

In-home Control

Electrical Specification Communication Protocol
Voltage Input Supply Current
Power Consumption Supported OS

32 50 15 2.4GHz
Internet LAN, Bluetooth
NS 5V 150 mA 750 mW Android 5 or later; IOS 9 or later

CEILING MOUNTED SERIES / P4

Specifications
A5CK Series (R410A)

Model

Indoor Unit Outdoor Unit

A5CM 15C A5CM 20C A5CM 25C A5CM 30C A5CM 30C A5CM 35C A5CM 40C A5CM 50C A5CM 62C A5LC 15F A5LC 20C A5LC 25C A5LC 28C A5LC 30C A5LC 35D A5LC 40D A5LC 50D A5LC 61D

Nominal Cooling Capacity Nominal Total Input Power

BTU/h kW W

12,500 3.66 1,270

18,000 5.27 1,760

21,000 6.15 2,020

27,000 7.91 2,820

29,000 8.49 2,950

35,000 10.25 3,800

42,000 12.31 4,100

44,500 13.04 4,900

55,000 16.11 6,414

Nominal Running Current EER

A

5.69

7.80

9.00

13.20

13.70

16.90

6.67

8.52

9.60

BTU/h/W

9.84

10.23

10.40

9.57

9.83

9.21

10.24

9.08

8.57

W/W

2.88

3.00

3.05

2.81

2.88

2.70

3.00

2.66

2.51

Power Source Refrigerant Type
Control
Air Flow

V/Ph/Hz

Operation Air Discharge
High

l/s / CFM 260 / 550

Medium l/s / CFM 228 / 484

220-240/1/50

380-415/3/50

R410A

WIRELESS REMOTE CONTROL

MANUAL (UP & DOWN)

287 / 608

374 / 792

480 / 1015 552 / 1107 589 / 1247 732 / 1550

276 / 586

334 / 707

439 / 930 471 / 999 560 / 1186 623 / 1320

Indoor Unit

Low

Sound Pressure Level (H/M/L) Height

Unit Dimension

Width

l/s / CFM 180 / 382

220 / 466

dBA 43 / 38 / 34 mm/ in

46 / 43 / 39

mm/ in

1203 / 47.36

289 / 613 46 / 44 / 40 235 / 9.25 1553 / 61.14

353 / 749 354 / 751 525 / 1113 472 / 1000 48 / 44 / 41 49 / 45 / 43 54 / 52 / 50 56 / 53 / 46
285 / 11.2 1903 / 74.92

Depth

mm/ in

680 / 26.77

Height Packing Dimension Width
Depth Unit Weight Condensate Drain Size

mm/ in mm/ in mm/ in kg/ lb mm/ in

293 / 11.54 1278 / 50.31

30 / 66

749 / 29.49 31 /68

1628 / 64.09
749 / 29.49 41 / 90
19.05 / 0.75

293 / 11.53

1,978 / 77.87

51 /112

749 / 29.49 52 /114 55 / 121

373 / 14.69 2,011 / 79.17
793 / 31.22 70 / 154

Air Flow

l/s / CFM 390 / 827 675 / 1,430 755 / 1,600

808 / 1,712

1,416 / 3,000

1,487 / 3,150

1,812 / 3,840

Sound Pressure Level Height

Unit Dimension

Width

Depth

Outdoor Unit
Packing Dimension

Height Width Depth

Unit Weight

Pipe Connection (Pipe Thickness)
Refrigerant Charge

Type Size

Liquid Gas

dBA mm/ in mm/ in mm/ in mm/ in mm/ in mm/ in kg/ lb
mm/ in mm/ in kg/ lb

48

49

52

54

56

58

60

60

65

550 / 21.65

651 / 25.63

753 / 29.65

852 / 33.54

658 / 25.91

855 / 33.66

1,030 / 40.55

273 / 10.75

328 / 12.91

400 / 15.75

580 / 22.83

693 / 27.28

793 / 31.22

1,010 / 39.76

775 / 30.51

990 / 38.98

1,180 / 46.46

355 / 13.98

415 / 16.34

415 / 16.34 415 / 16.34

514 / 20.24

29 / 63

43 / 94

47 / 103 57 / 125 57 / 125 71 / 156

84/185

105 / 232

Flare Valve

6.35 / 1/4

9.52 / 3/8

12.7 / 1/2

15.88 / 5/8

19.1 / 3/4

0.95 / 2.09 1.00 / 2.20 1.7 / 3.75 1.90 / 4.19 2.00 / 4.41 1.90 / 4.19 3.10 / 6.83 2.70 / 5.95 2.90 / 6.39

Remarks: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Normal Cooling Capacity is based in the conditions: Cooling 27°C DB/19°C WB indoor and 35°C DB/ 24°C WB outdoor. 3. Sound Pressure Level is according to JIS B 8615 standard. Position of the measurement point is 1m in front and 1m below the unit. 4. Units are tested & complied to international standards such as ISO 5151.

CEILING MOUNTED SERIES / P5

Specifications
A5CMY E & C Inverter Series

Model

Indoor Unit Outdoor Unit

Nominal Cooling Capacity
Nominal Total Input Power Nominal Running Current

EER

Power Source Refrigerant Type
Control

Operation Air Discharge
High

Air Flow

Medium

Low

Indoor Unit

Sound Pressure Level (H/M/L)

Height

Unit Dimension

Width

Depth

Height

Packing Dimension

Width Depth

Unit Weight

Condensate Drain Size Air Flow

Sound Pressure Level

Height

Unit Dimension

Width

Depth

Outdoor Unit

Packing Dimension

Height Width

Depth

Unit Weight

Pipe Connection (Pipe Thickness)

Type Size

Refrigerant Charge

Liquid Gas

BTU/h W W A
BTU/h/W W/W
V/Ph/Hz
l/s / CFM l/s / CFM l/s / CFM
dBA mm/ in mm/ in mm/ in mm/ in mm/ in mm/ in kg/ lb mm/ in l/s / CFM
dBA mm/ in mm/ in mm/ in mm/ in mm/ in mm/ in kg/ lb
mm/ in mm/ in kg/ lb

A5CMY 40E

A5CMY 50E

A5LCY 40FR 34,100

A5CMY 50FR 42,600

10,000

12,500

3,280

4,150

14.90

6.47

10.41

10.27

3.05

3.01

380-415 / 3 / 50

520 (1,100)

R410A WIRELESS AND WIRED AUTOMATIC LOUVER UP AND DOWN
570 (1,215)

464 ( 983) 414 ( 877) 52 / 47 /46

260 (10.24)

511 (1,082) 453 (959) 52 / 50 / 49

1,538 (60.55)

1,786 (70.31)

634

1,645 (64.76)

330 (12.99) 724 (28.50)

1,892 (74.49)

45 (99.21)
1553/3290 50

65 (143.30) 19.1 (3/4)
51

1534/3250

1,374 (54.09) 900 (35.43)

320 (12.60)

1,529 (60.20)

1,030 (40.55)

421 (16.57)

100 (220.46)

Flare Valve 9.52 (3/8) 15.88 (5/8)

4.3 /9.48

A5CMY 62C A5LCY 60FR
44,300 13,000 4,890
7.54 9.07 2.66
732 (1,550) 651 ( 1,320) 472 (1,000) 56 / 53 / 46 285 (11.22)
1,903 (74 608
351 (13.82) 2,016 (79.37) 788 (31.02) 70 (154.32)
51

Remarks: 1. All specifications are subjected to change by the manufacturer without prior notice. 2. Normal Cooling Capacity is based in the conditions: Cooling 27°C DB/19°C WB indoor and 35°C DB/ 24°C WB outdoor 3. Units are tested & complied to international standards such as ISO 5151.

CEILING MOUNTED SERIES / P6

Business Registration NO.198401017130 (129688-D)
CAT-A5CM-2103


Adobe InDesign 17.0 (Macintosh) 3-Heights™ PDF Optimization Shell 6.3.1.5 (http://www -tools.com)