Instruction Manual for Danfoss models including: KE07206 Ramped Valve Driver, KE07206, Ramped Valve Driver, Valve Driver

KE07206 Ramped Valve Driver Installation Guide

PDF preview unavailable. Download the PDF instead.

AN152886481728en-000203
THRESHOLD FWD F/S REV F/S RAMP TIME
1 2 3 4 5 6 7 8 9 10 11 12

Phased Out Products

3500 Annapolis Lane North, Minneapolis, MN 55447 Telephone: (763) 509-2084 Telefax: (763) 559-0108

Unit Specification
KE07206 Ramped Valve Driver

ISSUE: 1

DATE: May 1993

GENERAL DESCRIPTION

This device is a ramped valve driver which accepts a setpoint potentiometer input from a control handle and drives a dual coil electrical displacement control. It is pulse width modulated and has adjustable acceleration/deceleration ramping. The threshold, full stroke forward and full stroke reverse outputs are adjustable.

DIMENSION AND CONNECTION DIAGRAM

100,08 (3.94)
88,9 (3.50)

5,59 (0.22) 6,35 (0.25)
20,32 (0.8)

69,85 (2.75)

113,0 (4.45)

3,96 DIA (6) (0.156)

148,59 (5.85)

Dimensions in millimeters (inches).

N/C N/C N/C N/C POT GND GND +24V POWER OUTPUT - FWD POT +8V POT WIPER N/C OUTPUT - REV
1693

OUTPUT CHARACTERISTICS

SUPPLY VOLTAGE 24 Vdc
PWM FREQUENCY 1,000 Hz

OUTPUT CURRENT 200 mA
FACTORY SETTINGS WITH 22 OHM LOAD Threshold: 10 mA Full Stroke 200 mA

© Danfoss, 2013-09

K152.13 UNIT SPEC

. .

1

OUTPUT CURRENT - mA

OUTPUT CURRENT - mA

VALVE OUTPUT - % R40 MAX CCW
R40 MAX CW

Phased Out Products

ADJUSTMENTS
2

100 75 50 25

0123456 TIME - SECONDS
1679

FULL CW
200
150
FULL CCW
100

R18 FACTORY SETTING

FULL CW R18
FACTORY SETTING
FULL CCW

50

0
0 12 34 56 78 INPUT VOLTS
1690
Threshold adjustment.

FULL CW
200

FULL CW

150

100

R31

FACTORY

SETTING

50
FULL CCW

R30 FACTORY SETTING
FULL CCW

0
0 12 34 56 78 INPUT VOLTS

Full stroke adjustment.

K15213 UNIT SPEC

1691
© Danfoss, 2013-09

