User Manual for hoymiles models including: DTU-W100 3 Gen Wi-Fi Model, DTU-W100, 3 Gen Wi-Fi Model
Aug 15, 2020 — Note that only professionals can install or replace DTU. ○. Do not try to repair DTU without Hoymiles' approval. If DTU is damaged, please send the DTU.
©2019HoymilesPowerElectronicsInc.Allrightsreserved. 4 DTU-W1003Gen www.hoymiles.com Hoymilescustomerservicecenter:service@hoymiles.com 1.5 OtherInformation
File Info : application/pdf, 14 Pages, 740.32KB
DocumentDocumentVersion 2.1 (August 2020) DTU-W100 3 Gen Contents 1. Important Safety Information.................................................................................................................................. 3 1.1 Read this First.........................................................................................................................................................3 1.2 Safety Instructions................................................................................................................................................ 3 1.3 User...........................................................................................................................................................................3 1.4 Support and Contact Information.................................................................................................................... 3 1.5 Other Information.................................................................................................................................................4 2. About Hoymiles Microinverter System.................................................................................................................. 4 2.1 The Microinverter..................................................................................................................................................4 2.2 The DTU................................................................................................................................................................... 4 2.3 The Hoymiles Monitoring Server...................................................................................................................... 4 3. DTU Installation....................................................................................................................................................... 5 3.1 System Capacity.....................................................................................................................................................5 3.2 Basic Conditions Required.................................................................................................................................. 5 3.3 Dimensions............................................................................................................................................................. 6 3.4 Interface Layout.................................................................................................................................................... 6 3.5 Local Install Assistant...........................................................................................................................................6 3.6 System Installation Sequence............................................................................................................................7 3.7 DTU Installation Procedure................................................................................................................................ 7 4. Site creation on HMP.................................................................................................................................................. 9 5. Customer Login............................................................................................................................................................9 6. Complete Installation Map......................................................................................................................................10 7. Browse the Web Station...........................................................................................................................................10 8. View Phone APP......................................................................................................................................................... 11 9. LED indicator working status description........................................................................................................... 12 10. Troubleshooting...................................................................................................................................................... 12 11. Datasheet.................................................................................................................................................................. 13 © 2019 Hoymiles Power Electronics Inc. All rights reserved. 2 1. Important Safety Information DTU-W100 3 Gen 1.1 Read this First This manual includes important instructions for installing and maintaining the Hoymiles Data Transfer Unit (DTU). 1.2 Safety Instructions Symbol Usage Indicates a hazardous situation that can result in deadly electric shock hazards, other serious physical injuries, or fire hazards. Indicates directions which must be fully understood and followed in entirety to avoid potential safety hazards including equipment damage or personal injury. Indicates this points out that the described operation must not be carried out. The reader should stop, use caution, and fully understand the operations explained before proceeding. Note that only professionals can install or replace DTU. Do not try to repair DTU without Hoymiles' approval. If DTU is damaged, please send the DTU back to your installer for repairing/replacing. Disassembling DTU without Hoymiles' approval will invalidate remaining of the warranty period. Please read all instructions and warnings on the technical specifications carefully. Do not use Hoymiles products in a way that is not suggested by manufacture. Doing so may cause death or injury to persons or damage to equipment. 1.3 User This manual is only for professional installation and maintenance personnel to use. 1.4 Support and Contact Information If you have technical queries concerning our products, please contact your system installer or distributor. If further support is required, contact Hoymiles' support at this link. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 3 DTU-W100 3 Gen www.hoymiles.com Hoymiles customer service center: service@hoymiles.com 1.5 Other Information Product information is subject to change without notice. The user manual will be updated frequently, and please refer to Hoymiles official website at www.hoymiles.com for the latest version. 2. About Hoymiles Microinverter System 2.1 The Microinverter It converts the DC output of solar modules into grid-compliant AC power. It sends the output information of PV panels and the operation data of the microinverters to the DTU, which is the hardware basis of the panel-level monitoring. With conversion efficiency up to 96.7% and MPPT efficiency up to 99.9%, Hoymiles microinverters rank into the first class of the world's Microinverter industry. 2.2 The DTU The DTU is the key component in Hoymiles microinverter system. It works as the communication gateway, which operates between the Hoymiles microinverters and the Hoymiles Monitoring Server. The DTU communicates with the microinverter wirelessly via 2.4GHz Proprietary RF (Nordic), collecting the operation data of the system. Meanwhile, the DTU connects to the Internet via router and communicates with Hoymiles Monitoring Server. The microinverter system operation data will be uploaded to Hoymiles Monitoring Server via DTU. 2.3 The Hoymiles Monitoring Server It collects the operation data and status of the microinverters in the system and provides the panel-level monitoring for the users and maintenance staff. The following diagram shows the Hoymiles Microinverter system. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 4 DTU-W100 3 Gen 3. DTU Installation 3.1 System Capacity The DTU is capable of monitoring up to 99 pieces of single unit or 49 pieces of two in one unit or 24 pieces of four in one unit. If the communication between the DTU and microinverter caused by the installation conditions, the number of PV modules that the DTU can monitor may be reduced. 3.2 Basic Conditions Required Before installing the DTU, ensure the site meets the following requirements: Install close to the router. Stable Internet reception. The straight distance between DTU and Microinverter shall be less than 5 meters. The location should be one meter above the ground, 0.8 meters away from the corner. The environmental requirements for DTU installation: Away from dust, liquid, acidic, or corrosive gas. Temperature is between -20ºC and 55ºC © 2019 Hoymiles Power Electronics Inc. All rights reserved. 5 3.3 Dimensions DTU-W100 3 Gen 3.4 Interface Layout Item A B C Description USB Connector Status Indicator Reset Bottom 3.5 Local Install Assistant Local Install Assistant is a new function integrated with DTU-W100 3rd Gen, please download the Installer App (for installer/distributor use only) first. DTU-W100 has improved from the previous generation of DTU product, and developed with this new function that allows installer: A. One step to complete the WiFi configuration; B. Station overall Inverters status indication allows the installer to see how many MI under this DTU is working properly (and the details for each MI) and how many is abnormal (and the details for each MI) with one glance of eyes; © 2019 Hoymiles Power Electronics Inc. All rights reserved. 6 DTU-W100 3 Gen C. Add the Connection status, which will display the signal strength between each MI with connected DTU, so that installer can adjust the DTU installation location accordingly. This function will simplify the DTU installation, and avoid the second visit for installer due to the poor connection between DTU and certain MI. Note: Please refer to "Hoymiles Local Install Assistant Technical Note" for more details. 3.6 System Installation Sequence The DTU is capable of monitoring up to 99 pieces of single unit or 49 pieces of two in one unit or 24 pieces of four in one unit. 3.7 DTU Installation Procedure (1) Install the PV Modules and microinverters Please refer to the Microinverter's Manual or Quick Installation Guide for the detail installation steps. (2) Locate the DTU The maximum communication distance of Hoymiles DTU is 150m in open space. The walls, roofs, or other obstacles in between will affect the signal and reduce the communication distance in the real installation. The range of signal reduction for possible obstacles at the site has been shown below: Material Wood/Glass Relative signal range reductions 0-10% © 2019 Hoymiles Power Electronics Inc. All rights reserved. 7 DTU-W100 3 Gen Stone/Pressed cardboard Reinforced concrete (reduction increases with the amount of reinforcement) Metal 10%-40% 10%-90% Up to 100% Therefore, the DTU shall be placed as close to the microinverters as possible at the site to ensure good communication between DTU and microinverters. (3) DTU Installation a. Connect the DTU to the adapter and plug it into the wall socket. (Figure 1) Figure 1 b. If using Power Strip, please make sure it is placed at least 1 meter above the ground and try to install the DTU 90 degrees vertical to the ground as much as possible (figure 2). Figure 2 NotePlease do not install the DTU direct above the metal or concrete to prevent the signal dilution. (4) Start Procedure Once the DTU is powered on, the red, green and blue lights will flash every one second in turns for 30 seconds. (5) WiFi Configuration Use the smart phone/tablet open the Installer App and login. Approach to "Me" on the bottom of the page and then "Network Configuration". And input the house router's Network name and password, click "Send to DTU" to complete the WiFi configuration. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 8 DTU-W100 3 Gen 4. Site creation on HMP A. Install Hoymiles Installer APP by searching "Hoymiles" at the App Store (IOS) or Play Store (Android). B. Open the APP and login in with your installer account name and password. If you are a new installer with Hoymiles, please apply an Installer account from your distributor in advance. C. Add Station, select the "Station" tab on the bottom, then select "" on the right top side of the page. D. Select "Quick" for Single-DTU and "Profession" for Multi-DTU. E. Please fill in the station details accordingly, and press "Next" after completed. F. Press "Add DTU ID", scan the DTU ID (or you can manually input ID) and press "Next" after complete. G. Click "Start binding" and choose the angle and tilt base on the installation. H. Scan the Microinverter ID (or you can manually input the ID) and click the tick after completing each ID input. Press "Finish" once all Microinverter ID has been input. I. Disable the Scan function on the top of the right-hand side and design the Layout base on the installation. Click the tick box on the top of the right-hand side, and then select "Next" after completing the design. J. Upload a picture of the site and select "Finish" to complete the site creation. K. The new site will appear on the Station list from the Installer account. L. Please click the "Networking" button after the power station is created. M. Please wait about 30 minutes, the station will show online, and all the MI-IDs are found. 5. Customer Login A. Please download the End User App. You can search "Hoymiles" at the App Store (IOS) or Play Store (Android). B. Log in with the Password and Username that has been set up by Installer on the previous step (Section 6 step e), and press "Login". C. Customers will able to view all details once the data start to upload, normally it will need around 30 minutes for the first data coming through. D. Customers can also view the Microinverter generating details via accessing the HMP monitoring platform website at https://world.hoymiles.com. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 9 DTU-W100 3 Gen 6. Complete Installation Map When the system is energized, and the DTU detects the microinverters, you need to complete the installation map. A. Peel the serial number label from the DTU and place it on the installation map. B. Complete system information of the installation map shown below. 7. Browse the Web Station You can view the inverter real-time operating details on the computer web page by accessing Hoymiles online monitoring platform at https://world.hoymiles.com. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 10 DTU-W100 3 Gen 8. View Phone APP Download mobile phone APP by search "Hoymiles" at App Store (IOS) or Play Store (Android), log in with customer/installer account name and password, all installed Microinverters operating details will be able to view from there. © 2019 Hoymiles Power Electronics Inc. All rights reserved. 11 DTU-W100 3 Gen 9. LED indicator working status description Red Light Flashes every 1 second Flashes every 0.5 seconds Blue Light Flashes every 1 second Flashes every 0.5 seconds Green Light Flashes every 0.5 seconds Lights up constantly RED+GREEN+BLUE Each color flashes once every 1 second Each color flashes twice every 1 second Description DTU disconnect WiFi DTU disconnect with server Description No ID Received data From server Description The search ID is incomplete Normal Description Power on Firmware upgrade 10. Troubleshooting Indicator Red Status LED flash in Red every 1 second LED lights up in Red constantly Description DTU no ID inside and disconnect with Wi-Fi W100 with ID inside but no Wi-Fi connection Solution Check the distance between router and DTU, if it's over the range (refer to chapter 3.5 point 2) Check the distance between router and DTU, if it's over the range (refer to chapter 3.5 point 2) Double-check if the house router's password has been input correctly during the setting Use other device connect with the house router and make sure there is an effective reception Try to connect with the hot spot from the phone to see if any data is uploading successfully LED flashes in Red every 0.5 seconds DTU disconnect with server Re-do the configuration Double-check the Port and server address inside the DTU (Please contact Hoymiles Tech. Support team for the correct address) © 2019 Hoymiles Power Electronics Inc. All rights reserved. 12 Blue Green DTU-W100 3 Gen LED lights up in Blue constantly: LED flashes in Blue every 1 second: LED lights up in Green every 0.5 seconds: W100 has Wi-Fi connection but without ID inside. No ID The search ID is incomplete Complete the site creation on APP or Monitoring platform Complete networking Complete networking Re-locate the DTU to somewhere close to both router and Microinverter Note: Network Connection: 1. Connected to Wi-Fi, the blue indicator lights up, and then you can build the power station; 2. Can't connect to Wi-Fi, the indicator lights up as red + blue alternately flashing, and then you need to connect to Wi-Fi again. 11. Datasheet Model Communication to Microinverter Communication method Maximum distance (open space) Maximum number of inverters connected Communication to Cloud WIFI communication standard Data upload time Power Supply (Adapter) Power supply Adapter input voltage/frequency Adapter output voltage/current Power consumption Mechanical Data DTU-W100 2.4GHz Proprietary RF (Nordic) 150m 99 panels WiFi (802.11b/g/n) 15 minutes External Adapter with USB port 100 to 240 V AC / 50 or 60Hz 5V / 2A 1.0W (typical), 5W(maximum) © 2019 Hoymiles Power Electronics Inc. All rights reserved. 13 Ambient temperature range (°C) Size (W×H×D) Weight (KG) A fixed way Indicator light Others Standard DTU-W100 3 Gen -20°C to 55°C 143mm×33mm×12.5mm 0.1 Direct power supply LED EN60950 EN61000-3-2 EN61000-3-3 FCC 15B / 15C © 2019 Hoymiles Power Electronics Inc. All rights reserved. 14