User Manual for Tenmars models including: TM-306U Temperature Datalogger, TM-306U, Temperature Datalogger, Datalogger
1 day ago —
il y a 1 jour — Display : 3 digit LCD. ▫ LED status: red LED of Alarm, greed LED of Record. ▫ Sampling rate: 1 times/3 second. ▫ Battery : One 3.6V ½ AA lithium battery.
Temperature Datalogger Users Manual USB Datalogger IP 54 Water Proof Page 1 TABLE OF CONTENTS 1 FEATURES ................................................................................................................. 4 2 SPECIFICATIONS ...................................................................................................... 4 3 APPLICATIONS.......................................................................................................... 5 4 START UP AND GENERAL OPERATION.................................................................. 6 5 TURN ON TEMPERATURE DATA LOGGER ............................................................. 7 6 SWITCH BETWEEN OR ................................................................................. 8 7 RECORDING DATA .................................................................................................... 9 8 SAMPLING RATE ......................................................................................................11 9 TEMPERATURE CALIBRATION .............................................................................. 12 10 SOFTWARE INSTALLATION ................................................................................ 14 11 USING PC SOFTWARE......................................................................................... 15 12 CONNECTION STATUS ........................................................................................ 16 13 SETUP SCREEN ................................................................................................... 18 14 DOWNLOAD RECORDS....................................................................................... 19 15 GRAPHIC & CHART ANALYSIS ........................................................................... 21 16 DATA IN LISTING FORMAT .................................................................................. 23 17 DATA LISTING FORMAT....................................................................................... 24 18 DATA EXPORT ...................................................................................................... 25 Page 2 Page 3 1 FEATURES Measure / Temperature Datalogging- 50,000 records Fast USB download Easy- to-Use PC software for parameter settings and data analysis Internal Temperature alarm 2 Specifications Temperature Type Thermistor Measurement Range -40 to 85(-40~185) Accuracy ±1.2(0.6) from -4 to 122(-20 to 50) ±1.8(1.0) all other ranges Resolution 0.1 Display : 3 digit LCD. LED status: red LED of Alarm, greed LED of Record. Sampling rate: 1 times/3 second. Battery : One 3.6V ½ AA lithium battery Battery Lift :1 year. External Power Supply: 5 VDC with 0.5A. Operating temperature and humidity : -40 to 85(-40~185), 0-95%,RH,non-condensing. Instrument dimensions :83(L)*60(W)*24(H) mm. Weight : About 77g. Page 4 3 Applications Building HVAC monitoring. Warehouses. Refrigerator. Clean rooms. Freezer. Shipping vans. Shipping crates. Cargo vessels. Storage areas. WHAT'S IN THE BOX 1.Main Unit 2. USB Cable 3. 1/2 AA Battery Page 5 4 START UP AND GENERAL OPERATION LCD Display 1. Temperature Display 2. Recording 3. USB Communication 4. Battery Level Indicator 5. Unit of Measurement Page 6 5 Turn On Temperature Data Logger Press the Start button for 2 seconds to turn on the Temperature Data Logger. The unit is ready to use. Page 7 6 Switch between or Press / to switch between or Display current Temperature() Display current Temperature.( ) Page 8 7 Recording Data Press the Start button to start data recording. The LCD display will display REC and the LED green light twinkle when the Temperature Data Logger is recording. Page 9 Press the Start button again to stop recording. When recording stopped, the REC will disappear. Page 10 8 Sampling rate (5sec / 10sec / 1min / 5min / 10min / 30min / 1 hour) Data sampling rate can only be set from PC setup screen. Select the time interval from the drop-down menu. Click "Save Settings" to save the setting. Page 11 9 Temperature Calibration 1. The preparation 25 calibrator chamber. 2. Press and hold "/" button first, then press and hold "Start" button for 2 seconds to enter the calibration mode. 3. Press "Start" button to start the calibration. 4. During the calibration, the LCD will display the antenna sign. 5. The datalogger will start 25 calibration 20 minutes after the Start button is pressed. 6. When the calibration is completed, the COM will show up. Page 12 Press and hold the Start button for two seconds to turn off and restart the unit Page 13 10 Software Installation 1.Link website https://www.tenmars.com/ or scan below QR code: 2.Search TM-306U. 3.Click on the TM-306U photo. 4.Click File Download, then select Software Download. 5.Download and unzip the software. 6. For the latest software information and installation procedures, please refer to the software installation guide. Page 14 11 USING PC SOFTWARE Start Window PC software. Click on All programs, Click on "Temperature Data Logger" Click on STLogger to start the datalogger program. Page 15 12 Connection Status No Connection Screen Connect Temperature Data Logger to the PC with a USB cable. Page 16 Press Start for 2 seconds to turn on Temperature Data Logger. Temperature Data Logger is now connected to the PC. If the datalogger is properly connected, these three values will show up. 1. Temperature Reading 2. Battery Status 3. Display "Connected" Connected Screen Page 17 13 Setup Screen Click "Setup" to enter the Setup screen. he values in the white area can be changed by the user. The value in the grey area can not be changed by the user. Click "Save Settings" to save the values to the datalogger. Page 18 14 Download Records Click Download to download the stored data. Page 19 Click "Download" to start the download. Download Completed Page 20 15 Graphic & Chart Analysis Downloaded data will first be displayed in graph format. Page 21 Each data groups are listed according to the date of the sampling. Lowest group number represents earliest sampling date. Page 22 16 Data in Listing Format To display data in Listing format: Click File Click Chart Preview Page 23 17 Data Listing Format Page 24 18 Data Export Select export data type: Text or Excel CSV. Click Save to save the file in .CSV/Text format. File Saved. Page 25GPL Ghostscript 9.52