Adapter Box
Instruction txhais tesModel No.
WV-QJB500-W
WV-QJB500-S
WV-QJB500-G
Ceev faj
- Tsis txhob siv lub bracket no tshwj tsis yog nrog lub koob yees duab haum.
Yog tsis ua raws li qhov no yuav ua rau poob qis uas ua rau raug mob lossis raug mob. - Xa cov teeb tsa ua haujlwm rau lub chaw muag khoom.
Installation work requires technique and experience. Failure to observe this may cause fire, electric shock, injury, or damage to the product.
Nco ntsoov sab laj tus muag khoom. - Txhim kho cov khoom ruaj ntseg ntawm phab ntsa lossis lub qab nthab raws li cov lus qhia installation.
Yog tsis soj ntsuam qhov no yuav ua rau raug mob lossis raug mob. - Tsis txhob txhuam cov npoo ntawm cov hlau nrog koj txhais tes.
Tsis ua raws qhov no yuav ua rau raug mob.
Thaum siv cov khoom lag luam no, tseem nyeem "Cov Ntawv Ceeb Toom" uas tau piav qhia hauv cov lus qhia txog kev khiav haujlwm rau lub koob yees duab kom txuas nrog.
phau
Use this product when performing outdoor wiring of a box-type camera for outdoor or a wall mount bracket such as using a conduit.
For the latest information about the supported cameras, refer to our support webqhov chaw
(https://i-pro.com/global/en/surveillance/training_support/support/technical_information<ControlNo.:C0501,C0502>).
Specifications
Qhov kev khiav hauj lwm kub: | -50 ° C rau + 60 ° C (-58 ° F txog + 140 ° F) | |
Qhov ntev: | 115 hli (W) x 115 hli (H) x 40 hli (D) (4-17/32 inches (W) x 4-17/32 inches (H) x 1-11/16 inches (D)) |
|
Pawg: | Approx. 430 g (0.95 Ibs) | |
Tag Nrho: | Base bracket: Aluminum die cast Attachment plate: Stainless |
WV-QJB500-W: i-PRO white WV-QJB500-S: Silver VW-QJB500-G: Light gray |
* This product consists of an attachment plate and a base bracket and they are separately packaged.
Cov ntaub ntawv ceev faj rau kev teeb tsa
- In order to prevent injury, the product must be securely mounted to a ceiling or wall according to the Installation Guide of this bracket.
- Nco ntsoov tshem cov khoom no yog tias nws yuav tsis siv lawm.
Cov qauv siv ntxiv
Operating Instructions (this document) …….. 1 pc.
Installed auxiliary wire* ………………………….. 1 pc.
Hexagon screw …………………………………. 5 pcs.
(M4 × 14 mm {9/16 inches}) (of them, 1 for spare)
Fixing screws for attachment plate ………… 5 pcs.
(M4 × 10 mm {13/32 inches}) (of them, 1 for spare)
Screw for temporary fixing …………………… 2 pcs.
(M3 × 3.5 mm {1/8 inches}) (of them, 1 for spare)
* An installed auxiliary wire is equipped with the attachment plate.
Lwm yam uas xav tau (tsis suav nrog)
Fixing screws (M4) …………………. 4 pcs.
TSEEM CEEB
- Minimum pullout strength: 196 N {44 lbf} (per 1 pcs.)
- Tus nqi no qhia qhov tsawg kawg rub tawm lub zog xav tau tus nqi rau ib lub hau ntswj. Txog cov ntaub ntawv hais txog qhov tsawg kawg rub tawm lub zog, xa mus rau peb qhov kev txhawb nqa webxaib (https://i-pro.com/global/en/surveillance/training_support/support/technical_information<ControlNo.:C0120>).
- Select screws according to the material of the location where the camera will be mounted. In this case, wood screws and nails should not be used.
Npaj
Remove the tape fixing installed auxiliary wire (accessory) on the attachment plate.
When installing another bracket on this product
The following are descriptions of how to install WV-QWL500-W (Wall Mount Bracket) on this product as an example.
- Remove the installed auxiliary wire (accessory) from the attachment plate.
- Attach the screw for temporary fixing (accessory) to the bracket to be installed on this product.
Recommended tightening torque: 0.78 N·m {0.58 lbf·ft}
- If necessary, install the attachment plate provided with the camera to WV-QWL500-W by following the instructions described in the Operating Instructions of WV-QWL500-W.
When using a conduit
- Remove the cap for the female or thread for the conduit using a 5 mm hex wrench and attach the conduit.
The female thread for the conduit is compliant with ANSI NPSM (parallel pipe threads) 3/4 or ISO 228-1 (parallel pipe threads) G3/4.
installation
Step 1: Process the installation surface.
(Screw holes (4 places)/ Cable access hole (1 place))
When directly installing this product, process the installation surface.
Nco ntsoov:
- Determine the fixing screw hole diameter and depth in accordance with the specifications of the screws or anchors (x4) (M4: locally procured).
- When wiring using a conduit, it is unnecessary to process the cable access hole on the installation surface. Make a fixing screw hole so that the cable access hole (for conduit) of the base bracket is arranged in the direction of the conduit.
Depending on the condition of the ceiling or the wall surface, the following five patterns of screw positions are available for fixation of the base bracket. Use only the holes of the same pattern (A – E) for mounting.
Vertical | kab rov tav | |
A | 83.5 mm {3-9/32 inches} (82.5 mm {3-1/4 inches}) | 46 mm {1-13/16 inches} (47.6 mm {1-7/8 inches}) |
B | 46 mm {1-13/16 inches} (47.6 mm {1-7/8 inches}) | 83.5 mm {3-9/32 inches} (82.5 mm {3-1/4 inches}) |
C* | 83.5 mm {3-9/32 inches} (83.3 mm {3-9/32 inches}) | - |
D* | - | 83.5 mm {3-9/32 inches} (83.3 mm {3-9/32 inches}) |
E | 63 mm (2-15/32 inches} | 63 mm (2-15/32 inches} |
* When mounting to a single-gang junction box, fix with two fixing screws (M4: locally procured) using the holes of either pattern C or D.
Kauj ruam 2: Fix the base bracket on the installation surface or on a junction box.
Pass the cables through the base bracket and then fix the base bracket on the installation surface or on a junction box (locally procured) with fixing screws (M4: locally procured).
■ When installing the base bracket on the installation surface
Nco ntsoov:
- When installing this product outdoors, be sure to apply waterproofing to the cable access hole and the holes for fixing the screw.
The illustration shown on the left is an example when installing on a wall using the combination of the fixing screw holes that is 83.5mm {3-9/32inches} × 46mm {1-13/16inches}.
■ When mounting the base bracket to a junction box
Select the holes on the base bracket so that they match with the screw holes of the junction box.
Nco ntsoov:
- When using a two-gang junction box, it is recommended that the boxes are arranged side by side as shown in the illustration below. (The cable connection work on the empty box side will become easier.)
Step 3: Fix the attachment plate.
Fix the attachment plate with four fixing screws for the attachment plate (M4: accessory).
Recommended tightening torque: 1.37 N·m {1.01 lbf ft}
Nco ntsoov:
- When wiring using a conduit, complete the connection work on the base bracket side before fixing the attachment plate.
- When installing this product on a wall, fix the attachment plate with the “TOP⇧” mark facing upward.
- When installing this product on a ceiling, fix the attachment plate so that the “TOP⇧” mark is faced in the direction where the camera is aiming at.
Kauj ruam 4: Install a camera or other bracket on this product.
■ When installing a camera
The following are descriptions of how to install WV-U1542L (outdoor box type) on a wall using this product as an example. The installation procedure is the same for other cameras.
- Hang the camera by hooking the installed auxiliary wire on this product on the hook on the rear of the camera mount base as shown in the illustration on the right.
- Connect the cables by following the instructions in the Installation Guide of the camera.
- Temporarily fix the camera mount base by hooking the screw for temporary fixing onto this product.
- Fix the camera on this product with four hexagon screws (M4: accessory) using a 3 mm hex wrench (locally procured).
Recommended tightening torque: 1.37 N·m {1.01 lbf ft}
■ When mounting another bracket
The following are descriptions of how to install WV-QWL500-W (Wall Mount Bracket) on this product as an example.
- Pass the cable through WV-QWL500-W and temporarily fix it by hooking the screw for temporary fixing onto this product.
- Fix WV-QWL500-W on this product with four hexagon screws (M4: accessory) using a 3 mm hex wrench (locally procured).
Recommended tightening torque: 1.37 N·m {1.01 lbf ft} - Install the camera by following the Operating Instructions of WV-QWL500-W.
- Ua ntej sim sim txuas lossis teeb tsa cov khoom no, thov nyeem cov lus qhia no kom zoo zoo thiab khaws phau ntawv no rau siv tom ntej.
- Lub ntsej muag sab nraud thiab lwm qhov chaw hauv phau ntawv no yuav txawv qhov tseeb cov khoom lag luam nyob hauv qhov uas yuav tsis cuam tshuam rau kev siv li qub vim kev txhim kho cov khoom lag luam.
i-PRO Co., Ltd. assumes no responsibility for injuries or property damage resulting from failures arising out of improper installation or operation inconsistent with this documentation.
Ceeb toom: | Daim ntawv ceeb toom: |
• Before attempting to connect or operate this product, please read these instructions carefully. | • This product is not suitable for use in locations where children are likely to be present. • Do not install this product in locations where ordinary persons can easily reach it. • For information about screws and brackets required for installation, refer to the corresponding section of this document. |
Rau Asmeskas thiab Canada:
i-PRO Americas Inc.
Rau Tebchaws Europe thiab lwm lub tebchaws:
i-PRO EMEA BV
https://www.i-pro.com/
© i-PRO Co., Ltd. 2022NOS0520-1042
Luam tawm hauv Suav Teb
Cov ntaub ntawv / Cov ntaub ntawv
![]() |
i-PRO WV-QJB500-W Adapter Box [pdf] Phau Ntawv Qhia WV-QJB500-W, Adapter Box, WV-QJB500-W Adapter Box, Box |