  • Arrowg+ard Blue® Three-Lumen Catheter: 12 Fr. (4.1 mm OD) x 16 cm
  • Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow Advancer
  • Catheter: 18 Ga. x 2-1/2 "(6.35 cm) Radiopaque tshaj 20 Ga. RW Introducer Koob
  • Txhaj koob: 25 Ga. x 1 "(2.54 cm)
  • Blunt Fill Needle: 18 Ga. X 1-1/2 ″ (3.81 cm)
  • Pressure Transduction Probe
  • Introducer Needle: 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
  • Injection Needle: 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
  • Cov duab kos: 3 mL Luer-Xauv
  • Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
  • 5 mL 1% Lidocaine HCl tov thiab cawv Prep
  • 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®1 One-Step Solution with Hi-Lite Orange™ Tint
  • SharpsAway® II Locking Disposal Cup
  • SharpsAway® Disposal Cup
  • Drape: 41 "x 55" nrog 4" fenestration
  • Koob tuav
  • Kev Nyab Xeeb Lub Taub Hau: #11
  • Gauze Pad: 2 "x 2" (5 cm x 5 cm)
  • Gauze Pad: 4 "x 4" (10 cm x 10 cm)
  • Suture: 3-0 Silk with Curved Needle

1A registered trademark of CareFusion or one of its subsidiaries.

Rx xwb
Ceeb toom: Read all package insert warnings, precautions, and instructions prior to use. Failure to do so may result in severe patient injury or death. California Prop. 65
AR CEEB TOOM: Cancer thiab Reproductive Harm.
www.P65 Qhia rau sawv daws
Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Sterilized using ethylene oxide unless otherwise indicated in the contents list. Fluid path components are non-pyrogenic.
Cov Tshuaj Tiv Thaiv: The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine and/or sulfa drugs. ARROW AK-22123-CDC Lumen CVC for High Volume Infusions-FIG21

Priming volumes are approximate and are done without accessories. † Flow rate values are approximate and are determined using deionized water at 100 cm head height. Arrow International LLC Subsidiary of Teleflex Incorporated 3015 Carrington Mill Blvd. Morrisville, NC 27560 USA