HIKVISION DS-PDP18-EG2 Wired PIR Detector
Product Information
Specifications
- Model: DS-PDP18-EG2
- Type: Wired PIR Detector
- Security Grade: EN50131-2-2:2017
- Environmental Class: EN50131-1:2006+A1:2009+A2:2017+A3:2020 Security Grade (SG) 2 Environmental Class (EC) II
- Weight: 68g (2.4oz)
- Dimensions: 86.8mm x 65.4mm x 45.5mm
Frequently Asked Questions
Q: How do I adjust the sensitivity settings of the detector?
A: You can adjust the sensitivity settings to LOW, AUTO (Default), or HIGH using the provided instructions.
Q: What is the weight limit for pet immnity?
A: The weight limit for pet immunity is 5 kg for High sensitivity, 10 kg for Auto sensitivity, and 15 kg for Low sensitivity.
Disassembling the Detector
Identify and disassemble components: Lens, LED Light Pipe, PCB, Tamper Resistor Headers.
The Printed Circuit Board PCB
Identify components on the PCB like PIR Sensor, Terminals, Alarm Resistor Headers, and Tamper Spring.
Installation Method – Detector Backplane Installation
Follow instructions for installing the PIR Sensor, Terminals, and Alarm Resistor Headers on the detector backplane.
Installation Method – Bracket Installation
Install the bracket as per the instructions provided. Note that brackets are optional.
Installation Hints
Install the lens holder, nut, and casing screw as needed for proper functioning.
The 18m Lens
Adjust sensitivity settings to LOW, AUTO (Default), or HIGH based on the detection range required.
Resistor Wiring
Follow the instructions for resistor wiring based on the desired connection type (None, Single EOL, Double EOL).
For double and triple EOL connection, the detector has two method for resistor wiring:
- Use jumpers to select the End of Line resistance (Control panel dependent) on the ALARM/TAMPER pins.
- Select an resistance (Control panel dependent), and add the resistor to ALARM/TAMPER wiring ports of the detector.
Please select one resistor wiring method according to the figure below.- Alarm: 1K, 2K2, 4K7, 5K6, 6K8
- Tamper: 1K, 2K2, 4K7, 5K6
Connect to Control Panel
Connect the detector to the control panel based on the selected resistor wiring method.
- None Resistor Connection
- Single EOL Connection
- Double EOL Connection
Powering up
After powering on, the indicator flashes rapidly. Once the detector self test is completed, the LED indicator will go out until the detector detects movement.
Dimension and Weight
The detector dimensions and weight should be as specified for proper installation.
INSTALLATION CAUTION
The additional force shall be equal to three Nmes the weight of the equipment but not less than 50N. The equipment and its associated mounting means shall remain secure during the installation. Ayer the installation, the equipment, including any associated mounting plate, shall not be damaged.
Documents / Resources
![]() | HIKVISION DS-PDP18-EG2 Wired PIR Detector [pdf] User Guide DS-PDP18-EG2 Wired PIR Detector, DS-PDP18-EG2, Wired PIR Detector, PIR Detector, Detector |