Riello MBB 100 A 2P 3SW Multi Pass Data Center Switch

Riello-MBB-100-A-2P-3SW-Multi-Pass-Data-Centor-Switch-product

 Specifications

  • Product Name: Manual Transfer DATACENTER Switch
  • Models: Multi Pass 10, Multi Pass 16, Multi Pass 16-R, MBB 100 A 2P 3SW, MBB 125 A 4P 3SW, MBB 400 A 4P 3SW
  • Bypass: Maintenance Bypass included for Multi Pass 16, Multi Pass 16-R, MBB 125 A 4P 3SW Manufacturer: RPS SpA – Riello Power Solutions
  • Address: Viale Europa, 7 – 37045 Legnago (Verona) – ITALY
  • Contact: Tel: +39 0442 635811
  • Website: www.riello-ups.com

Installation

Ensure the product is placed on a stable surface and connected to the power source according to the provided guidelines.

 Operation

  1.  To transfer manually, locate the appropriate switch for the desired mode (Multi Pass or MBB).
  2. Follow the switch instructions to activate the transfer process

Multi Pass 10, 16, and 16-R

MAINTENANCE BYPASS

The Multi Pass manual bypass cuts out UPS in the event of a malfunction or fault. Multi Pass ensures that the connected devices are transferred to mains power before a UPS is switched off or during planned maintenance. Multi Pass is available for rack or wall installations (box)

FEATURES

  • 16 A rack version;
  • 10 A and 16 A wall-mounted version;
  • Standard backfeed protection.
  • Multi-Phase permits that the connected consumers are manually switched to mains power before a UPS is switched off or before maintenance.
  • Main power present LED indicator.
  • Available with different socket standards (IEC, British socket, terminal boards).

MBB 100 A 2P 3SW, MBB 125 A 4P 3SW and MBB 400 A 4P 3SR

MAINTENANCE BYPASS
Riello UPS offers several maintenance bypass solutions with two poles and four poles, suitable for single and three-phase applications. These devices are equipped with three switches to completely isolate the UPS in case of maintenance needs, keeping, at the same time, the load supplied by the mains without any interruption.n

Riello-MBB-100-A-2P-3SW-Multi-Pass-Data-Centor-Switch-fig-2

All the operations are done safely, thanks to a dedicated auxiliary contact that provides the status of the MBB to the UPS, avoiding any simultaneous supply from the manual bypass and inverter. Riello UPS offers a wide range of external bypasses and static switches for UPSs up to 800 kVA and for parallel systems up to 6.4 MVA.

RPS SpA – Riello Power Solutions – Member of the Riello Elettronica Group
Viale Europa, 7 – 37045 Legnago (Verona) – ITALY
Tel: +39 0442 635811
www.riello-ups.com

FAQs

Q: How do I know when to use the maintenance bypass feature?
A: The maintenance bypass feature should be used during maintenance activities or when the system needs to be serviced without interrupting the power supply.

Q: Can I operate the switch without referring to the manual?
A: It is recommended to familiarize yourself with the manual and follow the instructions provided for safe and efficient operation of the product.

Documents / Resources

Riello MBB 100 A 2P 3SW Multi Pass Data Centor Switch [pdf] User Manual
MBB 100 A 2P 3SW, MBB 125 A 4P 3SW, MBB 400 A 4P 3SW, MBB 100 A 2P 3SW Multi Pass Data Centor Switch, MBB 100 A 2P 3SW, Multi Pass Data Centor Switch, Data Centor Switch, Centor Switch, Switch