BRT-100 Radiator Thermostat(TRV)
User Guide

Zigbee Type For other languages,please scan the following QR code

Deutsch

Español

Welcome

Français

Italiano

Thank you for your purchase. MOES always made high-quality products with our high-end technology, high-quality craftsmanship, safe and reliable materials. The new radiator thermostat will bring you a more comfortable smart life . Please read this installation/ programming manual for installing and operating. Please also make sure someone qualified to install the radiator . Comply with all local regulations.

FEATURES

1. LED display, no window, wider perspective 2. Colorful display 3. Graceful arc waist shape 4. Rubber stretch paint, feel like baby skin 5. Night Halo colors your home 6. Low power consumption,battery can last 1 year for normal use and standby for 2 years. 7. Low battery tip 8. Diagram of temperature curve added in APP 9. Vary colors are available like white, Black, gray etc.

In the box you will find

Raditor Thermostat User Guide RA Adapter RAV Adapter RAVL Adapter Comap Adapter T+A Herz Adapter Herz Adapter

1pc 1pc 1pc 1pc 1pc 1pc 1set 1pc

Special note: The Zigbee version of the temperature control valve should be used with a Zigbee gateway compatible with "Tuya iot'". The package does not include the battery and gateway.

APPLICATION

DIMENSION

Unit: mm

52.0 48.5

71.5 85.0

M30*1.5 53.0
HOME SCREEN QUICK REFERENCE
Week

Valve open Error warning
Battery reminder Zigbee
Room temp.
Energy saving mode Set temp.
temp.display Manual mode

Low temp. protection Holiday mode Minute Hour Key lock
Open window
Programming mode

Down

Up

TECHNICAL DATA menu

Power Supply: 3 V,2xAA Batteries, Packaging not have battery. Maximum stroke: 4.5mm Accuracy: ± 0.5°C

Set Temp. Range: 5~45 °C Display temp. Range: 0~70°C Ambient Temp.: 0 ~ 45 °C Ambient Humidity: 5 ~ 95 % RH (Non Condensing) Storage Temp.: -5~ 45 °C Timing Error: < 1% Protection Class: IP 20 Buttons: Capacitive Touch Buttons
Before installing
To avoid damages to the product during installation,please read the manual carefully before installing TRV .
INSTALLATION
Step 1: Select the adapter.TRV is usually connected with
M30*1.5mm valve. If you have different valves, please determine your valve type according to the picture below, and choose the correct adapter from the package. If you do not find the valve that matches your use in the picture below, please buy it carefully.

Step 2: Install the adapter.Install the adapter on your valve
as the picture below. If you don't need an adapter, please ignore this step.

RA

RAV

Comap

RAVL

T+A Herz

Step 3: Install the thermostat mounting plate.Remove the
mounting plate of the thermostat (Part 1 in the picture below) counterclockwise.

Part 1

Follow the instructions in the figure below to install the mounting plate on the
valve. Pay attention to the
red label in the picture.

Step 4: Install battery
Follow the picture below to install the battery in the correct direction. After the battery is installed correctly, the thermostat will be turned on. At this time, click the (only once), the thermostat will display and flash "F1", when the "F1" stops flashing, the thermostat motor It will all shrink to facilitate the connection of the thermostat and the mounting plate.

Fig. 1

Step 5: Connect the thermostat and the mounting board
When "F1" stops flashing, find the "mark point" of the thermostat, shown Fig. 1.Turn clockwise to complete the connection between the thermostat and the mounting plate. After clicking the (only once), the thermostat will display "F2". When "F2 "disappears, while the screen remains on, turn the thermostat clockwise to adjust the screen to your liking direction.

Installation finished.

OPERATION
1. Power: After installing the battery, it will automatically turn on. It can't be turned off till the battery is removed. When the TRV is turned on, it will enter the self-check program, and all icons will be displayed firstly. Press , the screen flashes "F1", indicating that the temperature control valve is shrinking; when "F1" stops flashing, press again, The screen displays "F2",Indicates that the temperature control valve is measuring.; when the screen displays the room temperature, it indicates that the temperature control valve has completed the stroke measurement, and you can start using the temperature control valve normally.

2. Mode selection Press to switch between manual, programming, vacation modes. Manual mode - In this mode, the device executes manual temperature setting. When the set temperature is lower than the"minimum temperature", the valve is closed (forced closed); Programming mode -In this mode, the device executes a preset week programming temperature time and temperature; Holiday mode - In this mode, for example, the vacation mode is set for 10 days and the temperature is set to 15 degrees Celsius. After 10 days, the device will automatically switch to programming mode; Temporary manual mode - In this mode, icon will flash. At this time, the device executes the manually set temperature and returns to the weekly programming mode in the next time period.
3. Set the temperature Press "+"/"-" key to adjust the temperature 4. Set the clock Press and hold for 3 seconds, the screen will display "h" and numbers, indicating that the hour is being set, set the hour by press "+" / "-" keys; press again, the screen will display "m", indicating that the minute is being set, press "+" /"-" keys to set the minutes; press again, the screen will display "number", indicating that the day of the week is being set, and the day of the week can be set by "+" /"-" ;press again, the screen will flash "number, h, m", indicating that the number of days in the vacation mode is set, which can be set by the "+" and "-" keys; 5. Lock your Radiator Press the +" and"-" keys together for 3 seconds to lock or unlock the keys. 6. Low voltage reminder When the voltage is lower than 1.8V, the screen will display .
7. Boost heating Press and hold "+" for 3 seconds, the device will enter the boost heating mode, and the will flash.The countdown will be displayed in the APP.
8. Adjusting/Setting the Programmable Schedules Method one; Manually set a week of programming settings, specific operations are as follows: Method Two; Use APP for one week of programming settings, please refer to the second page "Programming your Radiator" Manual editing: Press and hold for 3 seconds. When you see the flashing numbers on the screen, press 4 times to skip the clock setting. When the screen displays "" (means Monday to Friday), flashing numbers and "h", you can set the hour with "+" and "-"; press again, flashing numbers and "m", you can use " +" "-" Set the minutes; press again, the screen displays "Set", and the temperature can be set by "+" "-". This completes the setting of the programmed temperature for one week in the morning from Monday to Friday. By analogy, refer to the one-week programming temperature default table to complete one-week programming settings.

8. Programming setting

Time display

MON.-FRI. ( shows on
scteen)

TIME

TEMP.

SAT. (shows on scteen)

TIME

TEMP.

SUN. (shows on scteen)

TIME

TEMP.

Period 1 6:00~11:30 20 6:00~12:00 24 6:00~12:30 19 Period 2 11:30~13:30 21 12:00~14:30 23 12:30~14:30 20 Period 3 13:30~17:30 22 14:30~17:30 22 14:30~18:30 21 Period 4 17:30~6:00 23 17:30~6:00 21 18:30~6:00 20

9. Setting the Functions and Options Press and hold the "-" and 3 seconds together , entering into the advanced option settings. The screen displays "A1" (function), after 2 seconds, the number (settings and options) will display, and the options can be set by the "+"/"-" key.

Code Function

A1

Temperature compensation

Setting and options -9 ~ 9

Default -2

Open window detection (After

the valve is opened, the room

temperature is 5-N°C, every 5

A2 minutes, check whether the

00close 01open

00

room temperature is lower

than the previous detection by

3°C)

When A2 is set to "01", the

device detects whether the

A3 room temperature has

N5-25

dropped by N°C compared

with the previous time

A4 When A2 is set to "01", close 5-60min the valve time

A5 Min.temp.

5-15

A6 Max.temp.

15-35

A7 Forced heating countdown

100-900s

A8 Detection valve head opening Open: ON Closed: OF

A9 Dead zone tempe.

0.5-5

AA Energy saving mode

00close 01open

AB

Energy saving mode temperature

5-35

AC Low temp. protection

0-10

AD Standby screen brightness

0-9

AE Factory reset

00: do not reset 01: reset

AF version number

5
15 5 35 300 (screen display 30) Can only show 1 00 20 5 00 00 U1

10. Command priority Priority judgment: In manual mode, Set to force close> Start low-temperature protection to force opening > Test window-opening to force closing > Boost heating

11. CE standard EMC, LVD,RF,ROHS

Common Abnormity and Processing Method

Error reminder

Failure description

icon+screen display The temperature sensor is

E1

disconnected orshort-circuited

"Exclamation mark" icon The thermostat cannot detect the

+ screen flashing E2

stroke

icon

Battery voltage is lower than 1.8V

Solution
Contact seller for replacement
Reinstall the battery to release Replacement battery

About Zigbee Step 1 Downlosd your APP (Fig. 2)

Fig. 2

IOS / Android

Search for "Smartlife" in the Apple Store or Google Play or scan the QR code above and follow the instructions of the APP to complete the installation.

Step 2 Connect the temperature control valve
Check the tutorial below to complete the connection and setup.

Scan QR code.
Note: Tuya zigbee wireless gateway is used by default. If you use a wired gateway, please check your gateway connection tutorial.

Long press "-" for 3s, as shown in the figure below (Fig. 3), the "Zigbee" icon will flash on the screen(Fig. 4).
Fig.3

flash
APP interface description
Battery power
Room temp. Manual Auto Temp. curve

Fig.4
Settings Set temp. Countdown to Boost heating. TempHand Holidays One week programming Advanced option settings

Temperature graph.
According to the temperature graph, you can understand the temperature change in the past time.
After-sales service in warranty period
Your thermostat is guaranteed for 24 months since the date of purchase. Service beyond the warranty period would need extra charges. For more details, please contact us directly. Thank you for your support and purchase at we MoesGo,we are always here for your complete satisfaction,just feel free to share your great shopping experience with us.
If you have any other need,please do not hesitate to contact us first,we will try to meet your demand.
YUEQING NOVA ELECTRONICS CO.,LTD Address: Qianhengcun, Liushi Town, Yueqing, Zhejiang, China Tel:+86-577-57186815 Email:service@moesgo.com AMZLAB GmbH Laubenhof 23, 45326 Essen Made In China

210421


GPL Ghostscript 9.26 Adobe Illustrator CC 23.0 (Windows)