HANYOUNG nux PAN20-TN PAN Series Area Sensor

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-Product image

Product Information: Area Sensor PAN Series

The Area Sensor PAN Series is a product manufactured by Hanyoung Nux. It is used to detect the presence or absence of an object in a specific area. The sensor operates through a through-beam sensing method using an IR (860nm) light source. It is available in two models, PAN20 and PAN40, with varying optical axis pitches and number of optical axis. The sensor has NPN or PNP control output options.

Specifications:

TypeModelSensing DistanceSensing ObjectOptical Axis PitchLight SourcePower VoltageCurrent ConsumptionControl Output
Through beamPAN20-TN7m20mm8-48 (depending on model)IR (860nm)Max. 170VMax. 100mANPN or PNP open collector
Through beamPAN40-TN7m40mm4-24 (depending on model)IR (860nm)Max. 170VMax. 100mANPN or PNP open collector

The sensor has a response time of maximum 15ms and is insulated
with a minimum resistance of 20M ohms (500VDC mega standard). It is
also equipped with noise immunity, dielectric strength, vibration
resistance, and shock resistance features for added protection.

Product Usage Instructions:

Before using the Area Sensor PAN Series, it is important to read the safety information carefully and use the product correctly. The alerts declared in the manual are classified into Danger, Warning, and Caution according to their importance. Please follow these alerts to prevent any product malfunction.

  1. Connect the sensor to a power source using the power supply (SMPS) and noise-eliminating condenser.
  2. Select the appropriate model and control output option for your application.
  3. Install the sensor in the desired location with a clear line of sight to the area to be detected.
  4. Set the operation mode using the M/S MODE switch for the transmitter and D/L MODE switch for the receiver.
  5. Check the operation LED and protection circuit for proper functioning.
  6. Ensure that ambient illumination is within the specified range of maximum 10,000 lux for sunlight and 3,000 lux for incandescent lamp.
  7. During operation, maintain an ambient temperature of -10 ~ +55 ℃ and humidity of 35 ~ 85% R.H. without condensation or icing.

PAN series

INSTRUCTION MANUAL

Thank you for purchasing Hanyoung Nux products. Please read the instruction manual carefully before using this product, and use the product correctly. Also, please keep this instruction manual where you can see it any time.

HANYOUNGNUXCO.,LTD

28, Gillaroo 71beon-gil, Michuholgu, Incheon, Korea
TEL : +82-32-876-4697 http://www.hynux.com

Safety information

Please read the safety information carefully before use, and use the product correctly. The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance.

DANGER
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage.

DANGER

The input/output terminals are subject to electric shock risk. Never let the input/output terminals come in contact with your body or conductive substances.

WARNING

  • The contents of this manual are subject to change without prior notice.
  • To prevent defection or malfunction of this product, supply proper power voltage in accordance with the rating.
  • Do not use the product at where subject to flammable or explosive gas.
  • Remove this product while the power is off. Otherwise, it may cause malfunction or electric shock.
  • Due to the danger of electric shock, use this product installed onto a panel while an electric current is applied.
  • To avoid electric shock, use this product installed on the panel.
  • This product is not for press safety sensors.
  • This product does not have control of the disaster prevention and accident prevention.
  • Hanyoung Nux shall not be liable for a damage and for a failure.

CAUTION

  • The contents of this manual are subject to change without prior notification.
  • If you use the product with methods other than specified by the manufacturer, there may be bodily injuries or property damages.
  • Do not decompose, modify, revise or repair this product. This may be a cause of malfunction, electric shock or fire.
  • Make sure that there is no damage or abnormality of the product during delivery.
  • Do not use this product at any place with a large inductive noise or occurring static electricity or magnetic noise.
  • Do not use this product at any place with possible thermal accumulation from direct sunlight or heat radiation.
  • When the product gets wet, the inspection must be done to avoid electric leakage or fire.
  • Make sure that the unused wire insulated.
  • Make sure to wire with correct polarity of terminals.
  • For the continuous and safe use of this product, the periodical maintenance is recommended.
  • Make wiring as short as possible, wire is recommended with its demission 0.5 ㎟ or more and maximum 25m.
  • Avoid continuously switching the power source On and Off.
  • Use a dry cloth to wipe off the substance when cleaning the lens or cases. Never use thinner or organic solvents.
  • Do not use this product where exposed to dust, vibration or impact.
  • Before inserting power source, make sure that the circuit wiring is properly connected.
  • In the case of wiring loaded inductors such as DC Relay and others to output, use diode, visitor and others to prevent surge.
  • To avoid malfunction caused by noise, do not put high voltage or power line with sensor wire in a same conduit
  • Prevent strong disturbance light such as sunlight and others which directly enter into the directional angle of the sensor by putting a glare shield.
  • When using the Switching Power Supply as the power source, earth the Frame Ground (F.G) terminal and be sure to connect the noise-eliminating condenser between 0 V and F.G.

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-01 

If you do not follow the contents described in the safety information then it is possible to be a cause of the product’s malfunction so please follow them.

Feature

  • Minimum beam pitch 20 ㎜, maximum beam pitch 40 ㎜.
  • Providing various detection range (140㎜ – 940㎜).
  • Mutual interference protection when installed in parallel (Max 2 sets).
  • Dark On/ Light ON operation selectable according to applications.
  • Easy to check and maintenance by operation display and Error indicator.

Suffix code

 Code 
PAN Model-□Area Sensor                         Content
Optical axis pitch20   20 ㎜
40   40 ㎜
Sensing methodT  Through Beam
Number of optical axis  Number of optical axis (Please refer to table below)
Control outputNNPN open collector
PPNP open collector
PAN208, 12, 16, 20, 24, 28, 32, 36, 40, 44, 48
PAN404, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24

Specification

  
Model NPNPAN20-T□N                   Through PAN40-T□N
PNPPAN20-T□PPAN40-T□P
Sensing distance 7 m 
Sensing object  
Optical axis pitch20 ㎜                        IR (86 40 ㎜
Light source 
Power voltage12 – 24 VDC ±10% Ripple(p-p)10% max
Current consumptionMax. 170 ㎃Max. 100 ㎃
Operation LEDLED), E1 display(Red LED), E2 display(Blue LED)
Protection circuitPower reverse connecMtiountuparlointetcetrifoenre, nOcuetpretvsahtoiornt-cfuirnccutiitoonver-current protection,
Response TimeMax. 15 ㎳
Insulation resistanceMin. 20 ㏁ (500 VDC mega standard)
Noise immunitySquare wave noise by noise simulator (pulse width 1 ㎲) ±240 V
Dielectric strength1,000 VAC (50/60 Hz 1min)
Vibration resistance10 – 55 ㎐, double amplitude: 1.5 ㎜, X·Y·Z in each direction for 2 hours
Shock resistance500㎨ , X·Y·Z each direction 3 times
Ambient illuminationSunlight : Max. 10,000 Lux, Incandescent lamp : Max. 3,000 Lux
Ambient temperatureDuring operation : -10 ~ +55 ℃, During storage : -25 ~ +70 ℃ (Without condensation or icing)
Ambient humidity35 ~ 85 % R.H. (Without condensation)
Degree of protectionIP65 (IEC standard)
Approval 
Connection method(Code length : 200 ㎜, RNeulamybceornonfewctiroersty: p4Pe, Dimension : Ø5.5 ㎜)
MaterialCaseAluminum
front coverAcryl
lensAcryl

Production formation

SeriesModelDetectionSeisntsainocnegNputimcablearxoefsDetectingCurrent(tComnasux)motionDetectable object
 

 

 

PAN20

PAN20-T8 

 

 

 

ThBreoaumgh

 

 

 

 

 

 

7 m

8 EA140 ㎜70 ㎃ 

Oopajeqcute Øab32ov㎜e

PAN20-T1212 EA220 ㎜80 ㎃
PAN20-T1616 EA300 ㎜90 ㎃
PAN20-T2020 EA380 ㎜100 ㎃
PAN20-T2424 EA460 ㎜110 ㎃
PAN20-T2828 EA540 ㎜120 ㎃
PAN20-T3232 EA620 ㎜130 ㎃
PAN20-T3636 EA700 ㎜140 ㎃
PAN20-T4040 EA780 ㎜150 ㎃
PAN20-T4444 EA860 ㎜160 ㎃
PAN20-T4848 EA940 ㎜170 ㎃
 

 

 

PAN40

PAN40-T44 EA120 ㎜50 ㎃ 

Oopajeqcute Øab52ov㎜e

PAN40-T66 EA200 ㎜55 ㎃
PAN40-T88 EA280 ㎜60 ㎃
PAN40-T1010 EA360 ㎜65 ㎃
PAN40-T1212 EA440 ㎜70 ㎃
PAN40-T1414 EA520 ㎜75 ㎃
PAN40-T1616 EA600 ㎜80 ㎃
PAN40-T1818 EA680 ㎜85 ㎃
PAN40-T2020 EA760 ㎜90 ㎃
PAN40-T2222 EA840 ㎜95 ㎃
PAN40-T2424 EA920 ㎜100 ㎃

Output Circuit

  • NPN Open Collector Output (N TYPE)
  • PNP Open Collector Output (P TYPE)

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-02

Dimension

PAN20 series

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-03

PAN40 series

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-04

TypeABCD1D2E1E2
PAN20-T8PAN40-T4227214.219773140120
PAN20-T12PAN40-T6307294.2277115220200
PAN20-T16PAN40-T8387374.2357157300280
PAN20-T20PAN40-T10467454.2437199380360
PAN20-T24PAN40-T12547534.25172311460440
PAN20-T28PAN40-T14627614.25972713540520
PAN20-T32PAN40-T16707694.26773115620600
PAN20-T36PAN40-T18787774.27573517700680
PAN20-T40PAN40-T20867854.28373919780760
PAN20-T44PAN40-T22947934.29174321860840
PAN20-T48PAN40-T2410271014.29974723940920

Indicator & Wiring classification

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-05

Operation LED classification

LED indicatorTransmitter
Red

Green

L.OFF when operation the MASTER / L.ON when operating the SLAVE

Power indicator

  

 

LED indicatorReceiver
RedOperation LED
GreenL.ON stability indicator
RedL.OFF with the disconnection or break of cluck (sync signal)/reset signal wire
BlueL.OFF with the appearance of disturbance light such as mercury lamp, luminescent light and etc.

Wiring and connecting classification

PIN NO.Wiring colorTransmitter
1

2

Brown

Orange

Power (12 – 24 VDC)

Sync wire

3BlueGND
   
4PurpleM/S

 

PIN NO.Wiring colorReceiver
1

2

Brown

Orange

Power (12 – 24 VDC)

Sync wire

   
3BlueGND
4BlackOutput

Operation chart

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-06

  • Green LED on the Transmitter is power indication.
  • The E1 indicator on the receiver (red led) is turn off when the sync line is shorted.
  • The E2 indicator on the receiver (blue LED) is turn off when there is a disturbance light such as sunlight,
  • fluorescent light, etc. (It may malfunction when the E2 indicator is turn off so please be careful)
  • In the case of Dark On, the operation indicator and control output operate in the reverse direction of Light ON.

MASTER / SLAVE Connection diagram

When two sensors are used close together, set them as shown below. Connect sensor A and sensor B according to the connection method in <Image 1>.

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-07

  • Open the connector cover at the bottom of the Transmitter (use the flat drive) and make the operation mode conversion
    switch as shown in Image 2 below. Set the Transmitter of sensor A to M (Master) and the Transmitter of sensor B to S (Slave)
  • Default = M (Master)

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-08

  • When using two sets of sensors together, wire them so that they do not become the master operation mode or the slave operation mode for both of them.
  •  Do not connect the sync lines of sensor A and sensor B to each other.
  •  Check the M / S indicator of the Transmitter after turning on the power.
    • Transmitter A (Master operation mode): M/S indicator is Turn off,
    • Transmitter B (Slave operation mode): M/S indicator is Turn on.

Operation Mode

HANYOUNG-nux-PAN20-TN-PAN-Series-Area-Sensor-08

  • Open the connector cover at the bottom of the Transmitter (use the flat drive), and use the operation mode switch to select the mode that meets the operating conditions.
  • Default mode: L (Light On) operation mode
  • L : LIGHT ON / D : DARK ON

Mounting and optical axis adjustment

  • After checking the connection status, turn on the power and check that the power indicator (green) of the Transmitter is turn on.
  • Move the Transmitter up, down, left, and right so that the light stability indicator (green) of the Receiver turns on.