HANYOUNG NUX HSR-PD Solid State Relay For PCB Substrate 

HANYOUNG NUX HSR-PD Solid State Relay For PCB Substrate

THANK YOU

Thank you for purchasing Hanyoung Nux products. Please read the instruction sheet carefully before using this product, and use the product correctly. Also, please keep this manual where you can view it any time.

Safety information

Please read the safety information carefully before the use, and use the product correctly. The alerts declared in the manual are classified into Danger, Warning and Caution according to their importance.

Symbol Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
Symbol Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
Symbol Indicates a potentially hazardous situation which, if not avoided, may result in minor injury or property damage.

SymbolDANGER

  • The input/output terminals are subject to electric shock risk. Never let the input/output terminals come in contact with your body or conductive substances.

Symbol WARNING

  • Please read the safety information carefully before the use, and use the product correctly.
  • Make sure that that the input / output terminals are not in contact with the body and energized objects as there is a danger of electric shock.
  • If there is a possibility of a a serious accident due to a malfunction or abnormality of this product, install an appropriate protection circuit on the outside, and plan to prevent accidents.
  • Please supply the rated power voltage, in order to prevent product breakdowns or malfunctions.
  • To prevent electric shocks and malfunctions, do not supply power until the wiring is completed.
  • Please disassemble the product after turning OFF the power.
  • Any use of the product other than those specified by the manufacturer may result in personal injury or property damage.
  • Please use this product after installing it to a panel, because there is a risk of electric shock.

Symbol CAUTION

  • Please make sure that the product specifications are the same as you ordered.
  • Please use the product in places where corrosive gases (especially harmful gases, ammonia, etc.) and flammable gases are not generated.
  • Please use the product in places without liquids, oils, chemicals, steam, dust, salt, iron, etc. (pollution degree 1 or 2).
  • Please avoid places where large inductive interference, static electricity, magnetic noise are generated.
  • Please avoid places with heat accumulation caused by direct sunlight, radiant heat, etc.
  • When water enters, short circuit or fire may occur, so please inspect the product carefully.
  • Do not wire anything to unused terminals.
  • When disposing of the product, treat it as industrial waste.
  • If the heat dissipation conditions, such as ventilation, are bad and the heat does not radiate, the product may malfunction or burn out.

Suffix code

Model

Code

Content

HSR-IconIconIconIconIconSingle-Phase Solid State Relay For PCB Substrate
Terminal typePPrinted circuit board (PCB) mount
Input control voltageD4 – 32 V d.c.
Rated load current033 A
055 A
088 A
Rated load voltage290 – 240 V a.c. (low voltage)
Operation typeZZero cross switching
RRandom switching

Specifications

ModelHSR-PD032ZHSR-PD052ZHSR-PD082Z
HSR-PD032RHSR-PD052RHSR-PD082R
InputControl signal voltage5 – 24 V d.c
Control signal range4 – 32 V d.c
ImpedanceMax. 4 kΩ
Operating voltageMin. 3 V d.c
Return voltageMax. 1.5 V d.c.
Current inputConstant-current system: 10 ㎃ (±3)
OutputRated load voltage100 – 220 V a.c
Load voltage range90 – 240 V a.c.
Peak voltage (non-repetition)600 V
Rated load current3 A5 A8 A
Frequency50 / 60 ㎐
Surge current30 A60 A120A
Leakage currentMax. 10 ㎃
Output ON voltage dropMax. 1.6 V (RMS)
Min. operating load0.5 A
Response speed1/2 cycle + max. 1 ㎳. (“R” type: max. 1 ㎳)
Insulation resistance500 V d.c., 100 ㏁ (between the input / output and case)
Dielectric strength2,500 V a.c. (60 ㎐ for 1 min)
Vibration resistance10 – 55 ㎐, double amplitude: 1.5 ㎜, X · Y · Z each axis 2 hours
Shock resistance1000 ㎨ (approx. 100 G), X · Y · Z each axis 3 times
Storage temperature-30 ~ 90 ℃
Ambient temperature-20 ~ 80 ℃
Ambient humidity45 ~ 85 % RH
CertificationSymbol
WeightApprox. 10 gApprox. 22 gApprox. 27 g

(note) the weight is calculated excluding the packing box

Dimensions

  • 3A(HSR-PD032Z,HSR-PD032R)
    [Unit: mm] Dimensions
  • 5 A (HSR-PD052Z, HSR-PD052R)
    Dimensions
  • 8 A (HSR-PD082Z, HSR-PD082R)
    Dimensions

PCB working dimensions (bottom view)
PCB working dimensions

Equivalent circuit
Equivalent circuit

Application circuit
Application circuit

Load current characteristics

  • Input voltage – current characteristics
    Dimensions
  • Load current characteristics
    Dimensions
  • Input current characteristics (non-repetition)
    Dimensions
  • Correct usage
    • If multiple SSR are installed together, space them more than 5 mm apart.
      Dimensions
    • The soldering should be done within 260 ℃ for 5 seconds.
    • The snubber circuit is not built in the output terminal.
    • When using the product at room temperature higher than the rated ambient temperature (25 ° C), use it at 80% or less of the rated load current. When the room temperature exceeds 40 ° C, HSR malfunction or burnout may occur.

Logo

Documents / Resources

HANYOUNG NUX HSR-PD Solid State Relay For PCB Substrate [pdf] Instruction Manual
HSR-PD032Z, HSR-PD032R, HSR-PD052Z, HSR-PD052R, HSR-PD082Z, HSR-PD082R, HSR-PD, HSR-PD Solid State Relay For PCB Substrate, Solid State Relay For PCB Substrate, State Relay For PCB Substrate, Relay For PCB Substrate, PCB Substrate, Substrate

References