1. Gabatarwa
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Acquaer Shallow Well Jet Pump, Model CCJC. This 1HP electric motor pump is designed for wells up to 25 feet deep, providing strong suction and water flow. It is suitable for various applications including irrigation systems, sprinkler setups, gardens, and supplying water to homes or small farms.

Acquaer Shallow Well Jet Pump overview, highlighting its performance capabilities.
2. Bayanin Tsaro
Please read and understand all safety warnings and instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.
- Koyaushe ka cire wutar lantarki kafin a gyara famfon.
- Tabbatar da ƙasa mai kyau don hana girgiza wutar lantarki.
- Do not operate the pump dry; always ensure it is primed with water before starting.
- Install the pump in a well-ventilated area, protected from freezing temperatures and direct sunlight.
- Yi amfani da kayan kariya na sirri masu dacewa (PPE) yayin shigarwa da kulawa.
3. Kayan Samfura
- Powerful 1HP Motor: Provides strong suction and high water flow, suitable for wells up to 25 feet deep.
- Dual Voltage Operation (115V/230V): The pump motor is designed to operate safely on either 115V or 230V power supplies. It is factory-set for 230V.
- Kariyar Zafi Mai Yawan Aiki ta atomatik: An intelligent system automatically shuts off the pump if it runs out of water or the motor overheats, preventing damage and extending product life.
- Maɓallin Matsi na Atomatik: Functions as a pressure booster, activating the pump when pressure drops below 20 PSI and deactivating it when pressure exceeds 40 PSI, ensuring consistent water supply. A pressure gauge is included on the casing for monitoring.
- Durable Cast Iron Volute: Constructed with a rugged cast iron casing for enhanced durability and reliable performance.

Key features including the capacitor motor, quality construction, and warranty information.
4. Abubuwan da suka wuceview
Familiarize yourself with the main components of your Acquaer Shallow Well Jet Pump:

- Priming Port: Used to fill the pump with water before initial operation.
- 1" NPT Outlet: Connection point for the discharge pipe.
- 1-1/4" NPT Inlet: Connection point for the suction pipe from the well.
- Voltage Box: Contains the electrical connections and voltage zabar canji.
- Akwatin Wuta: Houses the motor's electrical components.
- Ma'aunin Matsi: Nuna matsa lamba na ruwa na yanzu.
5. Saita da Shigarwa
5.1. Jirgin samatage Zabi
Your pump is factory-set to 230V. If your power supply is 115V, you must adjust the voltage switch before initial use. Refer to the diagram below:

- Don aiki na 115V: Ensure the switch is in the "115V" (down) position.
- Don aiki na 230V: Ensure the switch is in the "230V" (up) position.
CAUTION: Please select the correct voltage for the first time using to prevent damage to the pump.
5.2. Gyaran Famfon
Before starting the pump for the first time or after it has been drained, it must be primed with water to ensure proper operation and prevent damage from dry running.

- Mataki 1: Unscrew the priming port cap located on the top of the pump casing. Carefully pour water into the cavity until it is completely full.
- Mataki 2: Once the cavity is fully filled with water, reinstall the priming port cap securely. The pump is now ready for startup.
6. Umarnin Aiki
The Acquaer Shallow Well Jet Pump features an automatic pressure switch for convenient operation. Once properly installed and primed, the pump will manage water pressure automatically.
- The pump will automatically start when the system pressure drops below 20 PSI.
- The pump will automatically shut off when the system pressure reaches or exceeds 40 PSI.
- Monitor the built-in pressure gauge to observe system pressure.
- Ensure a continuous water supply to the pump inlet to prevent dry running.
7. Kulawa
Kulawa na yau da kullun yana tabbatar da tsawon rai da ingantaccen aikin famfo ɗin ku.
- Lokacin hunturu: In areas subject to freezing temperatures, drain the pump completely to prevent damage. Disconnect power, open drain plugs, and remove the priming cap to allow all water to escape.
- Duba Haɗin kai: Periodically check all pipe connections for leaks and tighten as necessary.
- Tsaftace Hatsari: Ensure motor cooling vents are free from debris to prevent overheating.
- Pressure Tank (if applicable): If used with a pressure tank, regularly check the air pressure in the tank, ensuring it is 2 PSI below the pump's cut-in pressure.
8. Shirya matsala
If you encounter issues with your pump, refer to the following common troubleshooting steps:
| Matsala | Dalili mai yiwuwa | Magani |
|---|---|---|
| famfo baya farawa | No power; Incorrect voltage setting; Motor overload. | Check power supply; Verify voltage switch position; Allow motor to cool and reset. |
| Pump runs but no water | Pump not primed; Air leak in suction line; Well dry. | Re-prime the pump; Check all suction line connections; Check well water level. |
| Ƙananan matsa lamba / kwarara | Partially clogged impeller; Air in system; Worn pump components. | Clean impeller; Bleed air from system; Inspect and replace worn parts. |
| Jump cycle yayi akai-akai | Leaking plumbing; Low air pressure in pressure tank. | Check for leaks and repair; Adjust pressure tank air charge. |
Idan matsaloli sun ci gaba, tuntuɓi ƙwararrun ma'aikatan sabis.
9. Ƙayyadaddun bayanai
Detailed technical specifications for the Acquaer Shallow Well Jet Pump, Model CCJC:

| Ƙayyadaddun bayanai | Daraja |
|---|---|
| Alamar | Acquaer |
| Lambar Samfura | CCJC |
| Salo | 1 hp |
| Kayan abu | Bakin Karfe |
| Voltage | 115V/230V (Dual Voltage) |
| Tushen wutar lantarki | Corded Electric |
| Matsakaicin Tsayin Hawa | 180 Kafafu |
| Girman samfur (L x W x H) | 16" x 8" x 8" |
| Well Depth Capability | Har zuwa ƙafa 25 |
| Abubuwan da aka haɗa | Ruwan Rijiyar Shallow |
10. Garanti da Tallafawa
Your Acquaer Shallow Well Jet Pump comes with a 24-month warranty, ensuring peace of mind regarding product quality and performance.
- Lokacin Garanti: Watanni 24 daga ranar siyan.
- Taimako: For technical assistance, warranty claims, or service inquiries, please refer to the contact information provided with your product packaging or visit the official Acquaer website.