Goodman GDVT96 Two Stage Variable Speed ECM Gas Furnace
Product Usage Instructions
- Installation
Follow the installation guidelines provided in the user manual. Ensure proper wiring as per the wiring diagrams. - Operation
Turn on the gas furnace using the control panel. Adjust the settings for desired temperature and fan speed. - Maintenance
Regularly clean and replace air filters to ensure efficient operation. Schedule professional maintenance checks annually.
Features
Standard Features
- Integrated communicating ComfortBridge™ Technology
- Commissioning and diagnostics via on board Bluetooth with the CoolCloud phone and tablet application
- Heavy-duty aluminized-steel tubular heat exchanger
- Stainless-steel secondary heat exchanger
- Two-stage gas valve provides quiet, economical heating
- Durable Silicon Nitride igniter
- Quiet two-speed induced draft blower
- Compatible with any single-stage thermostat
- Self-diagnostic control board with constant memory fault code history output to a triple 7-segment display
- Color-coded low-voltage terminals with provisions for electronic air cleaner
- Efficient and quiet variable-speed airflow system gently ramps up or down according to heating or cooling demand
- Multiple continuous fan speed options offer quiet air circulation
- Auto-Comfort and enhanced dehumidification modes available
- All models comply with California 40 ng/J Low NOx emissions standard
- Can no longer be installed in California’s South Coast
- Air Quality Management District (SCAQMD) on or after October 1, 2019.
Cabinet Features
- Designed for multi-position installation — upflow, horizontal left or right
- Certified for direct vent (2-pipe) or non-direct vent (1-pipe)
- Easy to install top venting with optional side venting
- Convenient left or right connection for gas and electrical service
- Cabinet air leakage (QLeak) ≤ 2%
- Heavy-gauge steel cabinet with durable baked-enamel finish
- Fully insulated heat exchanger and blower section
- Airtight solid bottom or side-return with easy-cut tabs for effortless removal in bottom air-inlet applications
* Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the Lifetime Heat Exchanger Limited Warranty (good for as long as you own your home), 10-Year Unit Replacement Limited Warranty and 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in Florida, California, or Québec. The duration of warranty coverage in Texas and Florida differs in some cases. Other limitations and exclusions apply; refer to complete warranty details for a full list of limitations and exclusions
Nomenclature
GRVT96 0403BN | GRVT96 0603BN | GRVT96 0803BN | GRVT96 0804CN | GRVT96 1005CN | GRVT96 1005DN | GRVT96 1205DN | |
HEATING DATA | |||||||
High Fire Input1 | 40,000 | 60,000 | 80,000 | 80,000 | 100,000 | 100,000 | 120,000 |
High Fire Output1 | 38,440 | 57,660 | 76,880 | 76,880 | 96,100 | 96,100 | 115,320 |
Low-Fire Input1 | 28,000 | 42,000 | 56,000 | 56,000 | 70,000 | 70,000 | 84,000 |
Low-Fire Output1 | 26,908 | 40,362 | 53,816 | 53,816 | 67,270 | 67,270 | 80,724 |
AFUE2 | 96.1 | 96.1 | 96.1 | 96.1 | 96.1 | 96.1 | 96.1 |
Temperature Rise Range (°F) High/Low Fire | 20-50 / 20-50 | 35-65 / 35-65 | 35-65 / 35-65 | 35-65 / 35-65 | 35-65 / 35-65 | 30-60 / 30-60 | 35-65 / 35-65 |
Vent Diameter3 | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ |
No. of Burners | 2 | 3 | 4 | 4 | 5 | 5 | 6 |
CIRCULATOR BLOWER | |||||||
Available AC @ 0.5” ESP | 1.5 – 3 | 1.5 – 3 | 1.5 – 3 | 1.5 – 4 | 2 – 5 | 2 – 5 | 2 – 5 |
Size (D x W) | 10″ x 8″ | 11″ x 8″ | 11″ x 8″ | 11″ x 10″ | 11″ x 10″ | 11″ x 11″ | 11″ x 11″ |
Horsepower @ 1075 RPM | 1/2 | 1/2 | 1/2 | 3/4 | 1 | 1 | 1 |
Speed | VS ECM | VS ECM | VS ECM | VS ECM | VS ECM | VS ECM | VS ECM |
FILTER SIZE (IN²) (QTY) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 16 x 25 (side or bottom) | (1) 20 x 25 (bottom) or (2) 16 x 25 (side) | (1) 20 x 25 (bottom) or (2) 16 x 25 (side) | (1) 20 x 25 (bottom) or (2) 16 x 25 (side) |
ELECTRICAL DATA | |||||||
Min. Circuit Ampacity 4 | 7.6 | 7.6 | 7.6 | 10.9 | 13.9 | 13.9 | 13.9 |
Max. Overcurrent Device (amps) 5 | 15 | 15 | 15 | 15 | 20 | 20 | 20 |
SHIPPING WEIGHT (LBS) | 114 | 117 | 120 | 141 | 143 | 153 | 156 |
- Natural Gas BTU/h; for altitudes 0-4500′ above sea level, reduce input rating by 4% for each 1000′ above 4500′ altitude.
- DOE AFUE based upon Isolated Combustion System (ICS)
- Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and CAN/CSA B142.2 (in Canada).
- Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
- Maximum Overcurrent Protection Device refers to the maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
- All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
- Gas Service Connection ½” FPT
- Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
- For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
- For servicing or cleaning, a 24” front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
GDVT96 Product Specifications
GDVT96 0403BN | GDVT96 0603BN | GDVT96 0804CN | GDVT96 1005CN | GDVT96 1205DN | |
Heating Data | |||||
High Fire Input¹ | 40,000 | 60,000 | 80,000 | 100,000 | 120,000 |
High Fire Output¹ | 38,440 | 57,660 | 76,880 | 96,100 | 115,320 |
Low-Fire Input¹ | 28,000 | 42,000 | 56,000 | 70,000 | 84,000 |
Low-Fire Output¹ | 26,908 | 40,362 | 53,816 | 67,270 | 80,724 |
AFUE² | 96.1 | 96.1 | 96.1 | 96.1 | 96.1 |
Temperature Rise Range (°F) High/Low Fire | 35-65 / 25-55 | 20-50 / 20-50 | 35-65 / 35-65 | 35-65 / 35-65 | 35-65 / 35-65 |
Vent Diameter³ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ | 2″ – 3″ |
No. of Burners | 2 | 3 | 4 | 5 | 6 |
Circulator Blower | |||||
Available AC @ 0.5″ ESP | 1.5 – 3 | 1.5 – 3 | 1.5 – 4 | 2 – 5 | 2 – 5 |
Size (D x W) | 10″ x 8″ | 11″ x 8″ | 11″ x 10″ | 11″ x 10″ | 11″ x 11″ |
Horsepower @ 1075 RPM | 1/2 | 1/2 | 3/4 | 1 | 1 |
No. of Speeds | VS ECM | VS ECM | VS ECM | VS ECM | VS ECM |
FILTER SIZE (IN²) (QTY) | (2) 10 x 20 or (1) 16 x 25 (top return) | (2) 10 x 20 or (1) 16 x 25 (top return) | (2) 10 x 20 or (1) 16 x 25 (top return) | (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) | (1) 14 x 20 (bottom) or (1) 20 x 25 (top return) |
Electrical Data | |||||
Min. Circuit Ampacity ³ | 7.6 | 7.6 | 10.9 | 13.9 | 13.9 |
Max. Overcurrent Device (amps) ⁴ | 15 | 15 | 15 | 20 | 20 |
Shipping Weight (lbs) | 116 | 119 | 143 | 145 | 158 |
- Natural Gas BTU/h; for altitudes 0-4500′ above sea level, reduce input rating by 4% for each 1000′ above 4500′ altitude.
- DOE AFUE based upon Isolated Combustion System (ICS)
- Vent and combustion air diameters may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada
- Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
- Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
- All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
- Gas Service Connection ½” FPT
- Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.
- For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.
- For servicing or cleaning, a 24” front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
GRVT96 Dimensions
Model | W | D | H |
GRVT960403BN | 17½” | 28⅞” | 34½” |
GRVT960603BN | 17½” | 28⅞” | 34½” |
GRVT960803BN | 17½” | 28⅞” | 34½” |
GRVT960804CN | 21” | 28⅞” | 34½” |
GRVT961005CN | 21” | 28⅞” | 34½” |
GRVT961005DN | 24½” | 28⅞” | 34½” |
GRVT961205DN | 24½” | 28⅞” | 34½” |
Air Discharge | Air Return | |||
A | B | C | D | E |
17½” | 16” | 13⅞” | 12⅛” | 13⅝” |
17½” | 16” | 13⅞” | 12⅛” | 13⅝” |
17½” | 16” | 13⅞” | 12⅛” | 13⅝” |
21” | 19½” | 17⅞” | 16″ | 17½” |
21” | 19½” | 17⅞” | 16″ | 17½” |
24½” | 23″ | 20⅞” | 19⅜” | 20⅞” |
24½” | 23″ | 20⅞” | 19⅜” | 20⅞” |
Minimum Clearances to Combustible Materials
Position | Sides | Rear | Front | Bottom | Flue | Top |
Upflow | 0″ | 0″ | 3″ | C | 0″ | 1″ |
Horizontal | 6″ | 0″ | 3″ | C | 0″ | 6″ |
C = If placed on combustible floor, the floor MUST be wood ONLY.
Model | W | D | H |
GDVT960403BN | 17½” | 28⅞” | 34½” |
GDVT960603BN | 17½” | 28⅞” | 34½” |
GDVT960804CN | 21” | 28⅞” | 34½” |
GDVT961005CN | 21” | 28⅞” | 34½” |
GDVT961205DN | 24½” | 28⅞” | 34½” |
Air Return | Air Discharge | |||
A | B | C | D | E |
17½” | 14⅝” | 14″ | 14½” | 16” |
17½” | 14⅝” | 14″ | 14½” | 16” |
21” | 18⅛” | 17½” | 18″ | 19½” |
21” | 18⅛” | 17½” | 18″ | 19½” |
24½” | 21⅝” | 21” | 21½” | 23″ |
Minimum Clearances to Combustible Materials
Position | Sides | Rear | Front | Bottom | Flue | Top |
Downflow | 0″ | 0″ | 3″ | NC | 0″ | 1″ |
Horizontal | 6″ | 0″ | 3″ | C | 0″ | 6″ |
- C = If placed on combustible floor, the floor MUST be wood ONLY.
- NC = For installation on non-combustible floors only. A combustible floor sub-base must be used for installations on combustible flooring.
GRVT96_GDVT96 Airflow Data
MODEL/TEMP RISE RANGE (MID-RISE) | GDVT960403BNA* 35-65 (50) | GDVT960603BNA* 20-50 (35) | GDVT960804CNA* 35-65 (50) | GDVT961005CNA* 35-65 (50) | GDVT961205DNA* 35-65 (50) | GRVT960403BNA* 20-50 (35) | ||||||
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended CFM for High Heat/ Expected Temperature Rise | 710 | 50 | 1400 | 38 | 1425 | 50 | 1770 | 50 | 2150 | 50 | 1010 | 35 |
Lowest Recommended CFM for High Heat/Expected Temperature Rise | 548 | 65 | 1072 | 50 | 1095 | 65 | 1360 | 65 | 1650 | 65 | 710 | 50 |
MODEL/TEMP RISE RANGE (MID-RISE) | GRVT960603BNA* 35-65 (50) | GRVT960803BNA* 35-65 (50) | GRVT960804CNA* 35-65 (50) | GRVT961005CNA* 35-65 (50) | GRVT961005DNA* 30-60 (45) | GRVT961205DNA* 35-65 (50) | ||||||
CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | CFM | RISE | |
Recommended CFM for High Heat/ Expected Temperature Rise | 1072 | 50 | 1400 | 50 | 1425 | 50 | 1770 | 50 | 1980 | 45 | 2150 | 50 |
Lowest Recommended CFM for High Heat/Expected Temperature Rise | 820 | 65 | 1090 | 65 | 1095 | 65 | 1360 | 65 | 1480 | 60 | 1650 | 65 |
NOTE: Low Heat CFM = High Heat CFM X .7. Low Heat Temperature Rise Is Expected to Equal High Heat Temparatue Rise ± 5%
GRVT960403BNA*, GRVT960603BNA* GRVT960803BNA*, GDVT960403BNA* GDVT960603BNA* COOLING SPEED (@ 0.1” – 0.8” w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
1.5 | 600 | 420 |
2 | 800 | 560 |
2.5 | 1,000 | 700 |
3 | 1,200 | 840 |
MAX | 1,400 |
GRVT960804CNA* GDVT960804CNA* COOLING SPEED (@ 0.1” – 0.8” w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
2 | 800 | 560 |
2.5 | 1,000 | 700 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
MAX | 1,760 |
GRVT961005CNA*, GRVT961005DNA* GRVT961205DNA* COOLING SPEED (@ 0.1” – 0.8” w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
2 | 800 | 560 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
5 | 2,000 | 1,400 |
MAX | 2,200 |
GDVT961005CNA* GDVT961205DNA* COOLING SPEED (@ 0.1” – 0.8” w.c. ESP)
TONS | HIGH-STAGE CFM | LOW-STAGE CFM |
2 | 800 | 560 |
3 | 1,200 | 840 |
4 | 1,600 | 1,120 |
5 | 2,000 | 1,400 |
MAX | 2,200 |
- All furnaces ship as high speed for cooling. Installer must adjust blower speed as needed.
- For most jobs, about 400 CFM per ton when cooling is desirable.
- Do not operate above .5” w.c. ESP in heating mode. Operating CFM between .5” and .8” w.c. is tabulated for cooling purposes only
Temperature Rise Range Chart
Wiring Diagram
MENU NAVIGATION AND SELECTION INSTRUCTIONS USING PHONE APPLICATION OVER BLUETOOTH NETWORK:
- CONNECT TO THE FURNACE (INSTRUCTIONS PROVIDED BY PHONE DURING THE CONNECTION PROCESS).
- SELECT DESIRED SETTINGS MENU
- SELECT ITEM THAT REQUIRES ADJUSTMENT AND MAKE NECESSARY SELECTION
- SUBMIT CHANGES
USING ON-BOARD PUSH BUTTONS:
- USE THE RIGHT AND LEFT BUTTONS TO SCROLL BETWEEN MENUS
- USE THE CENTER BUTTON TO SELECT DESIRED MENU WHEN MENU CODE IS SHOWN ON 7-SEGMENT DISPLAYS
- USE THE LEFT AND RIGHT BUTTONS TO SCROLL THROUGH OPTIONS WITHIN THE DESIRED MENU (THE DISPLAY WILL FLASH WHILE SCROLLING THROUGH OPTIONS FOR SELECTION)
- USE THE CENTER BUTTON TO SELECT THE DISPLAYED OPTION (WHEN SELECTED THE DISPLAY WILL STOP FLASHING)
- USE THE CENTER BUTTON TO FINALIZE SELECTION AND RETURN
TO THE MAIN MENU
AIRFLOW SETTINGS INSTRUCTIONS
- FOR NON-COMMUNICATING INSTALLATIONS, SELECT THE TYPE OF UNIT INSTALLED IN THE ODS MENU (1AC = SINGLE-STAGE AIR CONDITIONER,
- 1HP = SINGLE-STAGE HEAT PUMP, 2AC = 2 STAGE AIR CONDITIONER,
- 2HP = 2 STAGE HEAT PUMP) DEFAULT = OFF (NO OUTDOOR UNIT).
- THE TONNAGE MENU MUST BE USED TO SELECT COOLING/HEAT PUMP AIRFLOW (NON-COMMUNICATING INSTALLATION). TONNAGE SELECTION OPTIONS AND CORRESPONDING AIRFLOW CFM CAN BE FOUND TO THE RIGHT. [AIRFLOW = TONNAGE SELECTION X 400] DEFAULT SELECTION IS 6.0 TONS.
- [OPTIONAL] USE THE COOLING TRIM MENU (CTF) TO ADJUST THE COOLING AIRFLOW FROM -10% TO +10% (2% INCREMENTS). THIS APPLIES FOR 2 STAGE COMMUNICATING OUTDOOR UNITS AND SINGLE OR 2 STAGE NON-COMMUNICATING OUTDOOR UNITS.
- [OPTIONAL] USE THE HEATING TRIM MENU (HTF) TO ADJUST THE HEAT PUMP AIRFLOW FROM -10% TO +10% (2% INCREMENTS). THIS APPLIES FOR 2 STAGE COMMUNICATING OUTDOOR UNITS AND SINGLE OR 2 STAGE NON-COMMUNICATING OUTDOOR UNITS.
- [OPTIONAL] USE THE CONSTANT FAN MENU (FSD) TO SELECT THE PERCENTAGE OF MAXIMUM AIRFLOW FOR CONTINUOUS FAN
- [OPTIONAL] USE THE COOLING AIRFLOW PROFILE MENU (CAP) TO SELECT BETWEEN 5 COOLING AIRFLOW PROFILES. PROFILE OPTIONS 1-4 ARE LISTED ABOVE (OPTION 5 IS ADJUSTABLE). SEE INSTALLATION MANUAL FOR FURTHER DETAILS
NOTES:
- MANUFACTURER’S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING
- IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, AT LEAST 105%DG C. USE COPPER CONDUCTORS ONLY.
- UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.
- WHEN THIS FURNACE IS PAIRED WITH NON R-32 REFRIGERANT SYSTEMS, DEFAULT SETTINGS WILL NEED TO BE CHANGED. REFER TO INSTALLATION MANUAL FOR FURTHER INSTRUCTIONS
TONNAGE MENU | ||||
TONNAGE SELECTION | AIR FLOW | TONNAGE SELECTION | AIR FLOW | |
1.0 | 400 | 3.6 | 1440 | |
1.1 | 440 | 3.7 | 1480 | |
1.2 | 480 | 3.8 | 1520 | |
1.3 | 520 | 3.9 | 1560 | |
1.4 | 560 | 4.0 | 1600 | |
1.5 | 600 | 4.1 | 1640 | |
1.6 | 640 | 4.2 | 1680 | |
1.7 | 680 | 4.3 | 1720 | |
1.8 | 720 | 4.4 | 1760 | |
1.9 | 760 | 4.5 | 1800 | |
2.0 | 800 | 4.6 | 1840 | |
2.1 | 840 | 4.7 | 1880 | |
2.2 | 880 | 4.8 | 1920 | |
2.3 | 920 | 4.9 | 1960 | |
2.4 | 960 | 5.0 | 2000 | |
2.5 | 1000 | 5.1 | 2040 | |
2.6 | 1040 | 5.2 | 2080 | |
2.7 | 1080 | 5.3 | 2120 | |
2.8 | 1120 | 5.4 | 2160 | |
2.9 | 1160 | 5.5 | 2200 | |
3.0 | 1200 | 5.6 | 2240 | |
3.1 | 1240 | 5.7 | 2280 | |
3.2 | 1280 | 5.8 | 2320 | |
3.3 | 1320 | 5.9 | 2360 | |
3.4 | 1360 | 6.0 | 2400 | |
3.5 | 1400 |
MAXIMUM AIRFLOW OUTPUT
- 3 TON 60K BTUH = 1,400 CFM
- 3 TON 80K BTUH = 1,650 CFM
- 4 TON MODELS = 1,760 CFM
- 5 TON MODELS = 2,200 CFM
Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring
Warning
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death.
Accessories – GRVT96 / GDVT96
Model | Description | GRVT96 0403BN | GRVT96 0603BN | GRVT96 0803BN | GRVT96 0804CN | GRVT96 1005CN | GRVT96 1005DN | GRVT96 1205DN |
72950 | Concentric Vent Kit (2″) | √ | √ | √ | √ | √ | √ | ― |
72951 | Concentric Vent Kit (3″) | √ | √ | √ | √ | √ | √ | √ |
RF000142 | Drain Kit Horizontal Left Vertical Flue | √ | √ | √ | √ | √ | √ | √ |
EFR02 | External Filter Rack with 16″x25″ Permanent Filter | √ | √ | √ | √ | √ | √ | √ |
0170K00000S | Flush Mount Vent Kit – 3″ or 2″ | √ | √ | √ | √ | √ | √ | √ |
0170K00001S | Flush Mount Vent Kit – 2″ | √ | √ | √ | √ | √ | √ | ― |
HASFK | High-Altitude Natural Gas Kit | HASFK-1 | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-3 | TBD | HASFK-2 |
HASFK | High-Altitude LP Gas Kit | HASFK-1 | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-2 | TBD | HASFK-2 |
0270F05404 | Horizontal Drain Tubing Kit | √ | √ | √ | √ | √ | √ | √ |
LPM-34 | LP Conversion Kits | √ | √ | √ | √ | √ | √ | √ |
Model | Description | ADVT96 0403BN | ADVT96 0603BN | ADVT96 0804CN | ADVT96 1005CN | ADVT96 1205DN |
72950 | Concentric Vent Kit (2″) | √ | √ | √ | √ | ― |
72951 | Concentric Vent Kit (3″) | √ | √ | √ | √ | √ |
CFSB17 | Downflow Sub-Base 17.5″ | √ | √ | ― | ― | ― |
CFSB21 | Downflow Sub-Base 21″ | ― | ― | √ | √ | ― |
CFSB24 | Downflow Sub-Base 24″ | ― | ― | ― | ― | √ |
RF000142 | Drain Kit Horizontal Left Vertical Flue | √ | √ | √ | √ | √ |
0170K00000S | Flush Mount Vent Kit – 3″ or 2″ | √ | √ | √ | √ | √ |
0170K00001S | Flush Mount Vent Kit – 2″ | √ | √ | √ | √ | ― |
HASFK | High-Altitude Natural Gas Kit | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-3 | HASFK-3 |
HASFK | High-Altitude LP Gas Kit | HASFK-1 | HASFK-1 | HASFK-2 | HASFK-2 | HASFK-3 |
0270F05405 | Horizontal Drain Tubing Kit | √ | √ | √ | √ | √ |
LPM-34 | LP Conversion Kits | √ | √ | √ | √ | √ |
Notes
√ Indicates available for this model
Our continuing commitment to quality products may mean a change in specifications without notice.
©2024
• Houston, Texas • Printed in the USA.
FAQ
Q: How often should I replace the air filters?
A: Air filters should be checked monthly and replaced every 1-3 months depending on usage.
Q: What should I do if I encounter a fault code on the display?
A: Refer to the user manual to interpret the fault code. If needed, contact customer support for further assistance.
Documents / Resources
![]() | Goodman GDVT96 Two Stage Variable Speed ECM Gas Furnace [pdf] Owner's Manual GDVT961005CN, GRVT96 0403BN, GRVT96 0603BN, GRVT96 0803BN, GRVT96 0804CN, GRVT96 1005CN, GRVT96 1005DN, GRVT96 1205DN, GDVT96 Two Stage Variable Speed ECM Gas Furnace, Two Stage Variable Speed ECM Gas Furnace, Variable Speed ECM Gas Furnace, Speed ECM Gas Furnace, Gas Furnace |