User Manual for IRISBOND models including: 2024 Hiru Eye Tracking System, 2024, Hiru Eye Tracking System, Eye Tracking System, Tracking System, System
User manual. IRISBOND. Quick Start Guide: Windows. See it Possible. 1. Hiru First Steps Overview. Connect Hiru. Use the provided cables. Download and install eye gaze communication software
Aug 1, 2024 · Hiru eye tracker can be used with both: Windows and iOS (iPad Pro). The same eye tracker works with both operating systems. Mind Express 5: Hiru ...
File Info : application/pdf, 23 Pages, 3.01MB
DocumentDocumentHiru The only eye-tracker that works in Windows and iPadOS, indistinguishably User Manual | Quick Start Guide: Windows August 2024 User manual IRISBOND Quick Start Guide: Windows User Manual IRISBOND Hiru Eye Tracking System IRISBOND CROWDBONDING, S.L. All rights reserved. This document, including all supporting materials, is proprietary to IRISBOND CROWDBONDING, S.L. As this document may contain information that is confidential, proprietary, or otherwise legally protected, it must not be further copied, distributed, or displayed without the express written permission of IRISBOND CROWDBONDING, S.L. Products that are referred to in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the author make no claim to these trademarks. Contact Information IRISBOND CROWDBONDING, S.L Tolosa Avenue 75, 2nd floor 20018 Donostia-San Sebastián, Gipuzkoa, Spain +34 943 496 622 See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows What are you looking for? IRISBOND Hiru Eye tracker Hiru First Steps Overview 1 Compatibility 2 Multiplatform 2 Positioning 2 USB Connection and mounting 3 Assembly Options 4 How to mount Oskol 7 Use with different Operating Systems: Overview 8 How to update Hiru in Windows 9 Compliance Information: CE and MDR Declaration of conformity (MDR) Technical Specifications See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 1 Hiru First Steps Overview Install Systray This program includes the Drivers and updates needed for Hiru. Download and install eye gaze communication software (examples: Easyclick, Grid 3). Connect Hiru Use the provided cables. Calibrate in your Eye Gaze Software! Calibrating lets the Hiru adapt to your eyes so you have the best experience. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 2 If you want to use the eye tracker with larger screens, you can do so by changing the position of the camera and placing it further away from the screen. Compatibility Minimum requirements CPU 1,33 GHz RAM 8GB Storage: 128GB USB 3.0 -C Intel Graphics Nvidia and others with OpenGL 2.0 Multiplatform Hiru eye tracker can be used both with Windows and iOS (iPad). The same eye tracker works with both operating systems. We recommend iPad Pro / Surface Windows Pro iPadOS Windows iPad Pro 12.9" 5th and 6th generation Windows 7-11 Pro iPad Pro 11" 3rd and 4th generation Positioning Optimum working distance 55 cm. Optimum screen size 10" 20" inches See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 3 USB Connection and mounting Depending on the device that you may be using, an adaptor might be needed: For Windows devices, just use the long C-A cable. The C male connects to the Hiru and the A male connects to the device. For iPad PRO, the A-C adaptor is needed. Connect the adaptor to the iPad Pro, and the long cable to the Hiru. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 4 Assembly Options The IRISBOND Hiru system is designed to be fully adaptable for use with laptops, Desktop PCs, and tablets: Laptop Under the laptop or PC, fix the Hiru onto the holder with the provided screws. Click here to watch Set Up video for IRISBOND Hiru. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 5 Assembly Options Desktop Computer / Monitor Place the holder on a screen with the provided magnets and screw the Hiru to the holder. Click here to watch Set Up video for IRISBOND Hiru. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 6 Assembly Options Tablets 1. Attached to a tablet: Rehadapt's GA IRISBOND Hiru bracket (#16.1239). 2. Every Oskol casing comes by default with the Rehadapt's GA Universal adapter (#16.1224) mounted. Click here to watch Set Up video for IRISBOND Hiru. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 7 How to mount Oskol Oskol has a space dedicated for a Surface Pro tablet and another for Hiru. To mount the tablet in the Oskol follow these steps: 1 Remove the mounting plate and 3 screws. The screws and plate are included in the box. 2 Separate the top and bottom pieces of the casing. Push up on each side joint, until the top piece slides up. 3 Place the tablet in the bottom piece of the casing. The bottom corners of the tablet should sit tightly in the casing. 4 Place the top piece over the the tablet. Slide the top piece down until it is in place. The side joints and middle piece should fit together. 5 Place the screws in the back of the mounting plate. Use an allen wrench to tighten. 6 Place the Hiru in the slot below and Connect the cable. 2 4 6 5 1 3 3 6 2 4 6 6 See it Possible Click here to watch How to insert and remove a tablet and Hiru from Oskol. www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 8 Use with different Operating Systems: Overview Hiru eye tracker can be used with both: Windows and iOS (iPad Pro). The same eye tracker works with both operating systems. Keep in mind When using third party apps, the following Windows message may appear: If this is the case, please allow both private and public networks. Do this when installing Systray by clicking both check boxes. To change these settings after installing, enter "Windows Defender Firewall and select "allow an app of feature through Windows Defender Firewall", and enable the checkboxes accordingly. Windows Overview EasyClick: Our computer access software. EasyClick is now compatible with Duo and Hiru in the same app. Download this new version of EasyClick here and a course of how to use it here. Grid 3: From version 61 on, Grid 3 is integrated with Hiru. Select "Irisbond" from the available eye gaze cameras. Mind Express 5: Hiru is integrated with MindExpress 5. Select "Irisbond" from the available eye gaze cameras. Microsoft HID: It is possible to use Windows Eye Control with Hiru using HiruSystray app. For more information, please read the following document. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 9 How to update Hiru in Windows Hiru has continuous updates and new versions of firmware are released regularly. Update Hiru in Windows using our Systray app. Download the latest version of Systray app (below). Updating Hiru: Step by step Install Systray from this link: https://downloads.irisbond.com/systray Video tutorial Update your Hiru in Windows. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 10 How to update Hiru in Windows The Systray icon will open in the Windows Toolbar (see image below). If the Hiru is connected to the PC, the Systray will periodically check if there is a firmware update available. It is also possible to check for the updates by clicking in Check Updates. Keep in mind IRISBOND's Systray App should always be installed. If an update is available, a notification will show up, please, DO NOT disconnect the Hiru during this process. If no notification is shown, please check that your device that the Focus Assistant is OFF and Notifications for Systray are ON. Ensure the focus assistant is turned off, and notifications for Systray are turned on in Windows Settings in Notifications and Actions and be sure your WiFi is connected. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 11 To ease the access of the update with eyegaze, set the notifications to appear for more time. Go to: Settings > Ease of Access > Display. Set Notifications to show for 5 minutes. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows 12 How to update Hiru in Windows These are the notifications that you will receive once the process is started: See it Possible Updating... Updated, do not remove the Hiru. Now, the Hiru is ready to be used! Click here to check our Youtube channel and find out more about Hiru! www.irisbond.com User manual IRISBOND Quick Start Guide: Windows CE & MDR | Technical Specifications See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows Compliance Information: CE and MDR DECLARATION OF CONFORMITY The device model has been designed and manufactured in conformity with the Directive. San Sebastián, a 30th of April 2021 Eduardo Jauregui / Technical Director MANUFACTURER APPLICABLE DIRECTIVE HARMONIZED STANDARDS PRODUCT REFERENCE TEST CERTIFICATES IRISBOND CROWDBONDING, SL VAT: ES-B75091058 ADDRESS: AVENIDA DE TOLOSA, 75 - 2º San Sebastián CP: 20018 Guipúzcoa, País Vasco COUNCIL DIRECTIVE 93/42/EEC of 14 June 1993 concerning medical devices EN 55032 (2015) / AC (2016) / A11 (2020) EN 55035 (2017): UNE-EN 62471-1:2009 FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6 (2016) Sistema de control del ordenador con la mirada HIRU/ Eye tracking system HIRU IRISBOND HIRU 65321IEM.001 65321REM.001 65321REM.002 2251989-PHO-21-018A See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows Declaration of conformity (MDR) We, Irisbond Crowdbonding Ltd, declare that the product listed below has been designed and manufactured in conformity with the Directive (UE) 2017/745: MANUFACTURER IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 - 2º San Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com REFERENCE IRISBOND HIRU PRODUCT Eye tracking system HIRU The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonised legislation: APPLICABLE DIRECTIVE · Directive (UE) 2017/745 concerning medical devices, MDR. · EMC Directive, 2004/108/EC. · RoHS Directive, 2011/65/EU. · FCC Rules and Regulations. The following harmonized standards and technical specifications have been applied: HARMONIZED LEGISLATION EN 55032 (2015) / AC (2016) / A11 (2020) EN 55035 (2017) UNE-EN 62471-1:2009 FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6 (2016) TEST CERTIFICATES 65321IEM.001 65321REM.001 65321REM.002 2251989-PHO-21-018A This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows Declaration of conformity (MDR) We, Irisbond Crowdbonding Ltd, declare that the product listed below has been designed and manufactured in conformity with the Directive (UE) 2017/745: MANUFACTURER REFERENCE PRODUCT IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 - 2º San Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com OSKOL WINDOWS This product is composed by the following elements: · Medical device; Eye tracking system HIRU. · Case to bundle the Irisbond HIRU eye tracker and the Surface Pro tablet (TPU material has PASSED skin sensitization and cytotoxicity tests in accordance with ISO 10993-5 and 10993-10). The aim of this declaration is a Class I Medical Device and is in conformity with the following directives: APPLICABLE DIRECTIVE REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 on medical devices, MRD, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directive 90/385/EEC. The following harmonized standards and technical specifications have been applied: HARMONIZED LEGISLATION TEST CERTIFICATES HIRU: EN 55032: 2015 / AC: 2016 / A11: 2020 EN 55035: 2017 UNE-EN 62471-1:2009 FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6: 2016 OSKOL Windows: ISO 10993-5 ISO 10993-10 65321IEM.001 65321REM.001 65321REM.002 2251989-PHO-21-018A This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: Windows Declaration of conformity (MDR) We, Irisbond Crowdbonding Ltd, declare that the product listed below has been designed and manufactured in conformity with the Directive (UE) 2017/745: MANUFACTURER REFERENCE PRODUCT IRISBOND CROWDBONDING, SL ES-B75091058 AVENIDA DE TOLOSA, 75 - 2º San Sebastián, 20018 Guipúzcoa, Spain +34 9434 96 622 http://www.irisbond.com OSKOL iPad This product is composed by the following elements: · Eye tracking system HIRU, medical device class I. · Case to bundle the Irisbond HIRU eye tracker and the iPad Pro tablet (TPU material has PASSED skin sensitization and cytotoxicity tests in accordance with ISO 10993-5 and 10993-10) The aim of this declaration is a Class I Medical Device and is in conformity with the following harmonised legislation: APPLICABLE DIRECTIVE REGULATION (EU) 2017/745 OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 5 April 2017 concerning medical devices, MDR, amending Directive 2001/83/EC, Regulation (EC) No 178/2002 and Regulation (EC) No 1223/2009 and repealing Council Directive 90/385/EEC. The following harmonized and/or unharmonized standards and technical specifications have been applied: HARMONIZED LEGISLATION TEST CERTIFICATES HIRU: EN 55032: 2015 / AC: 2016 / A11: 2020 EN 55035: 2017 UNE-EN 62471-1:2009 FCC CFR 47, Part 15, Subpart B (10-1-15 Edition) ICES-003 Issue 6: 2016 OSKOL iPad: ISO 10993-5 ISO 10993-10 65321IEM.001 65321REM.001 65321REM.002 2251989-PHO-21-018A This declaration is signed on behalf of Irisbond Crowdbonding, Ltd in San Sebastián, on the 30th of April, 2021, by Eduardo Jauregui, CEO. See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: iOS Technical Specifications Optimum screen size Recommended working distance Calibration Selection mode Headbox Eye tracking Accuracy Sampling rate (Frequency) Mounting Operating system Eye Tracking processing Windows minimum system requirements (laptop, PC, tablet, hub) Windows recommended system requirements iPadOS minimum system requirements (laptop, PC, tablet, hub) 10-20" 37-75 cm. 5, 9, 16 points. 1 point fine-tuning Dwell, Blink, Switch 20 x 18 cm. at 50 cm. Monocular and binocular 0.4º 30-60 Hz Holder, magnets, or specific adaptor for consumer device Microsoft Windows 10 Pro. Apple iPadOS 17.5. Others: Please get in touch with us Hiru device-powered proprietary on-chip eye-tracking technology Eye-tracking processing is done at Hiru itself. System requirements related to the computer used with Hiru: USB3.0-Ctypeconnection 1,33GHzCPU 8GBRAM Storage:128GB IntelGraphics,Nvidia,andotherswithOpenGL2.0 WindowsSurfacePro7 HavethelatestversionoftheHiruappandfirmware. System requirements related to the tablet used with Hiru: iPadPro12,9"(6thgen) 8GBRAM Storage:128GB For IPadOS operation MFi certified hub suchas Satechi. Same as minimum and iPadOS 17.5 See it Possible www.irisbond.com User manual IRISBOND Quick Start Guide: iOS Technical Specifications requirements Weight Dimensions Eye tracking technology USB connector Have the latest version of the Hiru app and firmware. 115g 259 x 25 x 28 mm Dark pupil and proprietary algorithms USB-C Cable insertion and removal should be handled with care. See it Possible www.irisbond.com See it Possible Avenida de Tolosa, 75. Floor 2 Donostia - San Sebastián. 20018 Gipuzkoa Spain +34 943 49 66 22 www.irisbond.com info@irisbond.com