User Guide for Oakton models including: Ion 700 Meter 147-04 pH mv Ion Temp, Ion 700 Meter, 147-04 pH mv Ion Temp, mv Ion Temp

Product

OFI Testing Equipment, Inc.

Ion 700 Meter, pH/mv/Ion/Temp

electrodes Built-in electrode stand Selectable manual or ... “Ready” indicator, diagnostic messages Slide-out instruction card ...

il y a 7 jours — Description. Features Small footprint saves bench space Direct readout of ion concentration in ppm Oversized dual ...


File Info : application/pdf, 1 Pages, 18.86KB

PDF preview unavailable. Download the PDF instead.

product 779
OFI Testing Equipment, Inc. - 11302 Steeplecrest Dr. Houston, TX 77065 USA

Phone: 832-320-7300 - Email: sales@ofite.com

Ion 700 Meter, pH/mv/Ion/Temp

Brand: Oakton Product Code: 147-04 Lead Time: 21

Description <h2>Features</h2> <ul> <li>Small footprint saves bench space</li> <li>Direct readout of ion concentration in ppm</li> <li>Oversized dual display for easier viewing</li> <li>Features 0.1 mV resolution for ORP measurements</li> <li>Simultaneous display of ppm and mV electrode output in the ion mode</li> <li>Selectable buffer sets and fivepoint pH calibration with auto buffer recognition</li> <li>Works with many ion-selective electrodes</li> <li>Built-in electrode stand</li> <li>Selectable manual or automatic temperature compensation</li> <li>Built-in memory function</li> <li>Hold function, "Ready" indicator, diagnostic messages</li> <li>Slide-out instruction card for quick reference</li> </ul> <h2>Specifications</h2> <ul> <li>Measuring Parameters: ph, mV, Ion concentration, Temperature</li> <li>pH: <ul> <li>Range: -2.00 to 16</li> <li>Resolution: 0.01</li> <li>Accuracy: ±0.01</li> <li>Calibration: Up to 5 points</li> </ul> </li> <li>Millivolt: <ul> <li>Range: ±2000 mV</li> <li>Resolution: 0.1 mV from ±199.9 mV</li> <li>Accuracy: 1 mV beyond ±199.9 mV</li> <li>Calibration: Offset up to ± 150 mV</li> </ul> </li> <li>Ion: <ul> <li>Range: 0.01 - 2000 ppm</li> <li>Resolution: 0.01 ppm / 0.1 ppm / 1 ppm</li> <li>Accuracy: ±0.5% of reading (monovalent) ±1.0% of reading (divalent)</li> <li>Calibration: From 2 to 5 points</li> </ul> </li> <li>Temperature: <ul> <li>Range: 0.0° - 100.0°C (32° - 212°F)</li> <li>Resolution: 0.1°C (0.1°F)</li> <li>Accuracy: ±0.3°C (±0.5°F)</li> <li>Calibration: Offset 0.1°C Increments</li> <li>Temperature Compensation Automatic or Manual, 0 100°C</li> </ul> </li> </ul> <h2>Part Number</h2> <ul> <li>#147-04</li> </ul>

Powered by TCPDF (www.tcpdf.org)



References

TCPDF 6.3.5 (http://www.tcpdf.org)