1. Introduction et plusview
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Bürkert 134433 2/2-way servo-controlled solenoid valve. This valve is designed for reliable control of various media, featuring a media-separated pilot valve, suitable for 230V / 50-60Hz electrical systems, and equipped with a G 1/2 connection.
2. Consignes de sécurité
Always adhere to local safety regulations and guidelines when installing, operating, or maintaining the valve. Failure to do so may result in injury or damage to equipment.
- Sécurité électrique : Always disconnect power to the valve and associated circuits before performing any installation, maintenance, or troubleshooting. Ensure proper grounding.
- Sécurité sous pression : Ensure the system is completely depressurized and drained before working on the valve. Sudden release of pressure can cause severe injury.
- Compatibilité des médias : Verify that the valve's materials (brass housing, NBR seals) are compatible with the media being controlled to prevent corrosion or degradation.
- Équipement de protection individuelle (EPI) : Wear appropriate PPE, such as safety glasses, gloves, and protective clothing, when handling the valve or working with the system.
- Personnel qualifié: L'installation et la maintenance doivent être effectuées uniquement par du personnel qualifié et formé.
3. Description et caractéristiques du produit
The Bürkert 134433 is a high-quality 2/2-way servo-controlled solenoid valve designed for robust performance in various industrial applications. Its construction offers enhanced reliability and reduced sensitivity to impurities in the media.
Caractéristiques principales :
- Modèle: Bürkert 5282 134433
- Matériau du boîtier : Durable brass construction.
- Matériau du joint: NBR (Nitrile Butadiene Rubber).
- Impurity Tolerance: Less sensitive to impurities compared to direct-acting solenoid valves, ensuring longer service life.
- Fonctionnement réglable : Features continuously adjustable opening and closing times for precise control.
- Commande manuelle : Some Bürkert solenoid valves, including certain pivoted armature types, may feature a manual override for emergency or testing purposes.

4. Configuration et installation
Proper installation is crucial for the valve's performance and longevity. Follow these steps carefully:
- Préparation du système : Ensure the system is clean and free of debris before installing the valve. Flush pipes if necessary.
- Montage: Mount the valve in a position that allows for easy access for maintenance and inspection. The valve can typically be installed in any position, but for optimal performance and longevity, the coil should preferably be in an upright position.
- Sens de l'écoulement: Observe the flow direction arrow marked on the valve body. Install the valve so that the media flows in the indicated direction (IN-OUT).
- Connexion de tuyau: Connect the valve to the piping system using the G 1/2 threaded connections. Use appropriate thread sealant (e.g., PTFE tape) to ensure a leak-free connection. Do not overtighten.
- Connexion électrique : Connect the valve to a 230V / 50-60Hz power supply. Ensure the electrical connections are secure and comply with all local electrical codes. Verify correct voltage and frequency before applying power.
- Essai: After installation, slowly pressurize the system and check for any leaks. Test the valve's operation by applying and removing power to ensure it opens and closes correctly.
5. Fonctionnement
The Bürkert 134433 is a 2/2-way normally closed (NC) solenoid valve. When power is applied to the coil, the pilot valve opens, allowing system pressure to act on the main diaphragm, which then opens the main valve. When power is removed, the pilot valve closes, and the main valve returns to its closed position.
- Mise sous tension : Applying the specified 230V / 50-60Hz power to the coil will open the valve.
- Éteindre: Removing power from the coil will close the valve.
- Adjustable Times: If equipped with adjustable opening/closing time features, refer to the specific instructions provided with the valve for setting these parameters.
6. Entretien
Regular maintenance ensures optimal performance and extends the lifespan of your Bürkert valve. Always depressurize the system and disconnect power before performing any maintenance.
- Inspection de routine : Periodically inspect the valve for any signs of external damage, corrosion, or leaks. Check electrical connections for tightness and integrity.
- Nettoyage: Keep the exterior of the valve clean. Do not use harsh chemicals or abrasive materials that could damage the housing or labels.
- Remplacement du joint : The NBR seals are subject to wear over time, especially with continuous operation or aggressive media. If leaks occur or valve operation becomes erratic, inspect the seals and replace them with genuine Bürkert spare parts.
- Inspection de la bobine : Check the coil for any signs of overheating or damage. A damaged coil should be replaced immediately.
7. Dépannage
This section provides solutions to common issues you might encounter with your solenoid valve.
| Problème | Cause possible | Solution |
|---|---|---|
| La vanne ne s'ouvre pas lorsqu'elle est alimentée. | Pas d'alimentation ; volume incorrecttage/frequency; Damaged coil; Clogged pilot orifice; Excessive back pressure. | Check electrical connections and power source; Verify voltage and frequency match specifications; Replace coil; Clean pilot orifice; Ensure pressure differential is within limits. |
| La vanne ne se ferme pas lorsqu'elle est hors tension. | Debris lodged in valve seat; Damaged seal; Pilot orifice blocked; Residual pressure. | Disassemble and clean valve internals; Replace seals; Clear any blockages; Ensure system is fully depressurized. |
| Leakage from valve body or connections. | Loose pipe connections; Damaged seals; Cracked housing. | Tighten connections (do not overtighten); Replace worn or damaged seals; If housing is cracked, valve must be replaced. |
| Valve operates sluggishly. | Low pressure differential; Contamination; Worn internal components. | Verify system pressure; Clean valve internals; Inspect and replace worn components. |
8. Spécifications
Detailed technical specifications for the Bürkert 134433 solenoid valve:
| Attribut | Valeur |
|---|---|
| Fabricant | Bürkert |
| Numéro de modèle | 134433 (Bürkert 5282) |
| Type de vanne | 2/2-way Servo-controlled Solenoid Valve, Normally Closed (NC) |
| Matériau du boîtier | Laiton |
| Matériau du joint | NBR |
| Connexion électrique | 230 V / 50-60 Hz |
| Connexion de tuyau | Sol 1/2 |
| Nombre de ports | 2 |
| Dimensions du produit (L x l x H) | 8 x 8 x 38 cm |
| Poids | 0.95 grammes |
| Plage de pression | 0.2 - 10 bar |
9. Garantie et assistance
For detailed warranty information, please refer to the documentation provided with your purchase or contact your authorized Bürkert distributor. For technical assistance, spare parts, or further inquiries, please contact Bürkert customer service or visit their official website.
Always use genuine Bürkert spare parts to ensure compatibility and maintain product performance and warranty validity.