1. Introduction
This instruction manual provides essential information for the safe and effective use of your VOLTCRAFT AM-60X46/30V/DC Panel Meter. Please read this manual thoroughly before installation and operation, and retain it for future reference.
2. Consignes de sécurité
Avertissement: Electrical shock hazard. Improper use can result in injury or death. Always observe the following safety precautions:
- Assurez-vous que l’alimentation électrique est débranchée avant l’installation ou la maintenance.
- Seul un personnel qualifié est habilité à effectuer l'installation et le câblage.
- Ne dépassez pas le volume spécifiétagLa gamme de 30V DC.
- N’utilisez pas l’appareil s’il semble endommagé.
- Conservez l'appareil au sec et à l'abri des températures extrêmes.
3. Produit terminéview
The VOLTCRAFT AM-60X46/30V/DC is a compact analog panel meter designed for measuring DC voltage up to 30V. It features a clear, easy-to-read scale and a robust construction suitable for various applications.

Figure 1 : Devant view of the VOLTCRAFT AM-60X46/30V/DC Panel Meter. This image shows the meter's analog display with a scale from 0 to 30 volts, marked with 'V' for voltage, and the VOLTCRAFT logo. The needle is currently at 0V.
Caractéristiques principales :
- Analog display for direct voltage lectures.
- Measurement range: 0-30V DC.
- Compact dimensions (60 x 46 mm).
- Construction durable.
4. Installation et configuration
Follow these steps for proper installation of your panel meter:
- Coupure de courant : Ensure all power to the circuit where the meter will be installed is completely disconnected.
- Découpe du panneau: Create an appropriate cutout in your panel for the meter. Refer to the specifications section for exact dimensions (typically 60 x 46 mm).
- Montage: Insert the meter into the cutout from the front. Secure it from the rear using the provided mounting hardware (if applicable).
- Câblage : Connect the meter to the DC voltage source you wish to measure. Observe correct polarity: connect the positive (+) terminal of the meter to the positive side of the circuit, and the negative (-) terminal to the negative side. Incorrect polarity may damage the meter.
- Vérification: Double-check all connections for security and correct polarity before restoring power.
5. Mode d'emploi
Once installed and wired correctly, the VOLTCRAFT AM-60X46/30V/DC Panel Meter operates automatically:
- Mise sous tension : Restore power to the circuit. The meter's needle will move to indicate the measured DC voltage.
- Lecture de l'affichage : Lire le voltage value directly from the scale indicated by the needle. The scale ranges from 0 to 30V.
- Ajustement zéro : If the needle does not rest precisely on zero when no voltage is applied, use the small screw located at the bottom center of the meter face to carefully adjust it. This adjustment should only be performed when the meter is disconnected from any voltagla source.
6. Entretien
The VOLTCRAFT AM-60X46/30V/DC Panel Meter requires minimal maintenance:
- Nettoyage: Clean the meter's front panel with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Inspection: Inspectez périodiquement les connexions électriques pour vous assurer qu'elles sont bien fixées et exemptes de corrosion.
- Stockage: If storing the meter, keep it in a dry, dust-free environment within its specified operating temperature range.
7. Dépannage
| Problème | Cause possible | Solution |
|---|---|---|
| Meter needle does not move. | No power to the circuit; incorrect wiring; damaged meter. | Check power supply; verify wiring polarity and connections; replace meter if damaged. |
| Meter shows incorrect reading. | Incorrect wiring; meter not calibrated (rarely needed for analog meters); external interference. | Verify wiring; perform zero adjustment if needle is off at 0V; ensure no strong magnetic fields are nearby. |
| Needle is stuck or erratic. | Physical damage; internal fault. | Inspect for physical damage; if internal fault is suspected, replace the meter. |
8. Spécifications
- Marque: VOLTCRAFT
- Numéro de modèle : AM-60X46/30V/DC
- Type de mesure: Vol CCtage
- Plage de mesure : 0 - 30 V/DC
- Dimensions: 60 x 46 mm (approximate panel cutout size)
- Poids: 44 gramme
- Source d'alimentation : Manual operation (passive measurement)
- ASIN: B00CS2GZ5C
9. Garantie et assistance
For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact VOLTCRAFT customer service directly. Keep your purchase receipt as proof of purchase.
Spare parts availability: 1 Year (as per product information).