VOLTCRAFT SDM-115

Manuel d'utilisation de l'appareil de mesure d'épaisseur de revêtement VOLTCRAFT SDM-115

1. Introduction

The VOLTCRAFT SDM-115 Coating Thickness Gauge is designed to quickly and accurately measure the coating thickness on metallic surfaces. This device helps determine if a painted or repaired surface requires repainting or further repair. It is suitable for use on both ferromagnetic (e.g., steel) and non-ferromagnetic (e.g., aluminum) metals, offering a measurement range of 0-1000 µm.

2. Consignes de sécurité

Veuillez lire et comprendre toutes les consignes de sécurité avant d'utiliser l'appareil. Le non-respect de ces consignes peut entraîner des blessures ou endommager l'appareil.

  • Gardez l'appareil à l'abri de l'eau et de l'humidité.
  • N’essayez pas d’ouvrir ou de modifier l’appareil. Confiez toute réparation à un personnel qualifié.
  • Utilisez uniquement le type de pile spécifié. Respectez la polarité lors de l'installation des piles.
  • Évitez d'exposer l'appareil à des températures extrêmes ou à la lumière directe du soleil.
  • Tenir hors de portée des enfants.

3. Produit terminéview

The VOLTCRAFT SDM-115 is a handheld coating thickness gauge featuring an ergonomic design for comfortable use. It includes a digital display and intuitive control buttons for calibration, unit selection, and backlight control.

VOLTCRAFT SDM-115 Coating Thickness Gauge, front view

Figure 3.1 : Devant view of the VOLTCRAFT SDM-115 Coating Thickness Gauge, showing the display and control buttons.

Caractéristiques principales :

  • Measures coating thickness on ferromagnetic and non-ferromagnetic metals.
  • Measurement range: 0-1000 µm.
  • Two-point calibration for enhanced accuracy.
  • Digital display with backlight.
  • Unit selection between mils and micrometers (µm).
VOLTCRAFT SDM-115 Coating Thickness Gauge, side view

Figure 3.2 : Côté view of the VOLTCRAFT SDM-115, highlighting its ergonomic design and trigger.

4. Installation

4.1 Installation de la batterie

The VOLTCRAFT SDM-115 requires batteries for operation (not included). To install batteries:

  1. Locate the battery compartment cover, typically on the handle of the device.
  2. Faites glisser ou déclipsez le couvercle pour ouvrir le compartiment.
  3. Insérez les piles requises en veillant à respecter la polarité (+/-) indiquée à l'intérieur du compartiment.
  4. Fermez soigneusement le couvercle du compartiment à piles.

5. Mode d'emploi

5.1 Mise sous/hors tension

Press and hold the trigger or power button (if available) to turn the device on. The display will illuminate. To turn off, press and hold the same button or wait for automatic shutdown.

5.2 Prendre une mesure

To take an accurate coating thickness measurement:

  1. Ensure the measurement surface is clean, dry, and free of debris.
  2. Place the sensor head of the gauge firmly and perpendicularly onto the surface to be measured.
  3. The device will automatically display the coating thickness reading on the screen.
  4. Lift the device from the surface to prepare for the next measurement.
VOLTCRAFT SDM-115 Coating Thickness Gauge in use

Figure 5.1 : The VOLTCRAFT SDM-115 being used to measure a surface.

5.3 Modification des unités de mesure

The device supports measurement in both mils and micrometers (µm). To switch between units, press the button labeled mils/µm sur le panneau de commande.

6. Étalonnage

For optimal accuracy, especially when measuring different materials or after prolonged use, two-point calibration is recommended. The device features a CAL button for initiating the calibration process.

While the exact steps for two-point calibration may vary, generally it involves:

  1. Placing the gauge on a known zero-thickness surface (e.g., bare metal).
  2. En appuyant sur la CAL button and following on-screen prompts to set the zero point.
  3. Placing the gauge on a surface with a known standard thickness (e.g., a calibration foil).
  4. En appuyant sur la CAL button again and using the arrow buttons to adjust the reading to match the known standard thickness.
  5. Confirming the calibration.

Refer to the detailed instructions provided with your specific calibration foils or the full product manual for precise calibration procedures.

7. Entretien

7.1 Nettoyage

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the sensor head is kept clean and free of dust or residue for accurate readings.

7.2 Stockage

Rangez l'appareil dans un endroit frais et sec, à l'abri de la lumière directe du soleil et des températures extrêmes. En cas de stockage prolongé, retirez les piles pour éviter les fuites.

8. Dépannage

  • L'appareil ne s'allume pas : Vérifiez l'installation des piles et assurez-vous qu'elles ne sont pas déchargées. Remplacez-les si nécessaire.
  • Lectures inexactes ou incohérentes :
    • Ensure the sensor head is clean and free of debris.
    • Perform a two-point calibration as described in Section 6.
    • Verify the measurement surface is clean, dry, and flat.
    • Ensure the device is placed perpendicularly and firmly on the surface.
  • Device beeps excessively or shows unusually high values: This often indicates a need for calibration. Follow the calibration steps in Section 6 carefully. Ensure you are using appropriate calibration standards.

9. Spécifications

Numéro de modèleSDM-115 (Article No. 100847)
FabricantVOLTCRAFT
Plage de mesure0-1000 µm
Dimensions (L x l x H)10.5 x 4.2 x 14.8 cm
Poids9.07 grammes
Piles requisesOui
Piles inclusesNon

10. Garantie et assistance

For warranty information, technical support, or service inquiries, please refer to the documentation included with your purchase or contact VOLTCRAFT customer service directly. Please have your model number (SDM-115) and article number (100847) available when contacting support.