Danfoss013G2960

Manuel d'utilisation de la tête thermostatique Danfoss RA/VL2960

Modèle: 013G2960

Produit terminéview

The Danfoss Thermostatic Head Type RA/VL2960 is a renovation head designed for use with RA/V 34 mm valve bodies. It provides manual temperature control for heating systems, featuring a frost protection function and the ability to limit or lock temperature settings. This product is a direct replacement for older Danfoss RA/V thermostatic heads produced before 1986, ensuring compatibility and ease of upgrade for existing installations.

The package includes one Danfoss thermostatic head Type RA/VL2960.

Danfoss Thermostatic Head RA/VL2960

Figure 1 : Face avant view of the Danfoss Thermostatic Head RA/VL2960, showing the white body with numbered temperature settings and the Danfoss logo.

Configuration et installation

The Danfoss RA/VL2960 thermostatic head is designed for straightforward installation on compatible RA/V valve bodies with a 34 mm neck inner diameter. No special tools are typically required beyond a flat-head screwdriver for the clamping ring connection.

Étapes d'installation :

  1. Préparation: Ensure the heating system is depressurized if replacing an old valve or if there is any risk of water leakage. For head replacement only, this may not be necessary, but always exercise caution.
  2. Retirer l'ancienne tête (le cas échéant) : If replacing an existing thermostatic head, loosen the clamping ring or connection mechanism that secures it to the valve body. Carefully remove the old head.
  3. Set New Head: Before mounting, set the new Danfoss RA/VL2960 thermostatic head to its highest setting (typically '5' or 'MAX') to ensure the valve pin is fully retracted. This facilitates easier installation.
  4. Positionner et attacher : Place the new thermostatic head onto the valve body, aligning it correctly. The head is designed to fit securely over the valve's neck.
  5. Connexion sécurisée : Serrez le clamping ring connection firmly using a flat-head screwdriver. Ensure the head is securely fastened and does not wobble. Do not overtighten.
  6. Vérifier l'opération : Once installed, turn the thermostatic head through its settings to confirm smooth operation and proper engagement with the valve pin.
Diagram showing compatibility of Danfoss RA/V thermostatic head with older models

Figure 2: Compatibility diagram illustrating how the new Danfoss RA/V head replaces older thermostatic heads produced before 1986, highlighting the 34mm valve diameter.

Mode d'emploi

The Danfoss RA/VL2960 thermostatic head allows for manual control of room temperature by regulating the flow of hot water through the radiator. The head features numbered settings, typically from '*' (frost protection) to '5' (maximum heat).

Contrôle de la température :

  • Réglage de la température : Rotate the head to the desired setting. Higher numbers correspond to higher room temperatures.
  • Frost Protection (*): Setting the head to the '*' symbol activates the frost protection function. This setting ensures the room temperature does not fall below approximately 6-8°C (43-46°F), preventing pipes from freezing.
  • Limiting/Locking Settings: The head may have mechanisms to limit the maximum or minimum temperature settings, or to lock it at a specific setting. Refer to the markings on the head for specific instructions on how to engage these features, if present. This is useful for preventing accidental changes or maintaining a consistent temperature.
Gros plan view of the Danfoss Thermostatic Head RA/VL2960 showing temperature settings

Figure 3: Close-up of the thermostatic head showing the numbered dial for temperature adjustment and the Danfoss branding.

Danfoss Thermostatic Head installed on a radiator in a room setting

Figure 4: The Danfoss thermostatic head installed on a radiator, demonstrating its integration into a home heating system.

Entretien

The Danfoss RA/VL2960 thermostatic head requires minimal maintenance to ensure optimal performance and longevity.

  • Nettoyage: Periodically wipe the exterior of the thermostatic head with a soft, damp Chiffon. Évitez d'utiliser des nettoyants abrasifs ou des solvants, car ils peuvent endommager la finition.
  • Contrôle saisonnier : Before the heating season begins, it is advisable to turn the thermostatic head through its full range of settings a few times. This helps to prevent the valve pin from sticking due to prolonged inactivity.
  • Circulation d'air : Ensure that the thermostatic head is not obstructed by curtains, furniture, or other objects, as this can interfere with its ability to accurately sense room temperature and regulate heat.

Dépannage

If you experience issues with your Danfoss RA/VL2960 thermostatic head, consider the following common solutions:

ProblèmeCause possibleSolution
Radiator remains cold or only partially heats up.
  • Thermostatic head set too low.
  • Valve pin stuck in closed position.
  • Air in the radiator.
  • Obstruction around the head.
  • Increase the temperature setting on the head.
  • Remove the head and gently press the valve pin several times to free it. Reinstall the head.
  • Purgez le radiateur pour libérer l'air emprisonné.
  • Ensure no curtains or furniture are blocking the head.
La pièce est trop chaude malgré le réglage au minimum.
  • Thermostatic head not sensing room temperature accurately.
  • Valve pin stuck in open position.
  • Ensure the head is not exposed to direct heat sources (e.g., sunlight, other appliances).
  • Remove the head and check if the valve pin is fully extended. If not, gently pull it out. Reinstall the head.
Head feels loose or wobbly.Clamping ring not sufficiently tightened.Serrez le clamping ring connection with a flat-head screwdriver.

If these steps do not resolve the issue, it may indicate a problem with the valve body itself or the heating system, and professional assistance may be required.

Caractéristiques

MarqueDanfoss
Nom du modèle013G2960
Dimensions du produit2.48"P x 2.13"L x 3.31"H
Type de contrôleurAnneau
CouleurBlanc (RAL 9016)
Type de contrôle de températureManuel
Composants inclusThermostatic head for RA/VL 2950 body (diameter: 34 mm)
Source d'énergieManuel
Poids de l'article150 grammes (5.3 onces)
Voltage230 Volts (Note: This refers to the system voltage, not the head itself which is manual)
Type de montageWall Mount (on radiator valve)
StyleRenovation head 2960 RA/V 34 mm
Code UPC793518448210 791429257891
FabricantConmetall
Des piles sont-elles nécessaires ?Non

Garantie et assistance

Specific warranty details for the Danfoss RA/VL2960 thermostatic head are typically provided at the point of purchase or within the product packaging. Please retain your proof of purchase for warranty claims.

For technical support, installation queries, or further assistance, please contact Danfoss customer service or visit the official Danfoss website. You can find contact information on the Danfoss website ou auprès de votre distributeur local.

Officiel Danfoss Website: www.danfoss.com

© 2024 Danfoss. Tous droits réservés.