FIRST - logo

 www.firstdegreefitness.com
First Degree Fitness
FIRST DEGREE FITNESS Apollo Pro V Rowing Machine

Speed Sensor Trouble Shooting
and Replacement Guide for
Apollo AR
and
Apollo PRO 

Sensor Troubleshooting

  1. Check the gap between the sensor and the magnetic ring should be 2-3mm FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Sensor Troubleshooting
  2. Visually check all 6 magnets in the magnetic ring are present and flush (no need to remove the ring)
    FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - remove
  3. Check sensor head – the internal sensor should be no more than a few millimeters inside the hole
    FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - millimeters inside
  4. If the above checks fail to resolve the issue continue to the next section 

Sensor Removal

FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Frame Plug 2 FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Speed Sensor FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Disconnect FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Speed Sensor
Remove the Frame Plug Pull the Speed Sensor out of
the frame
Disconnect the sensor cables Remove the washer from
the Speed Sensor

Sensor Re-Installation

FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Fit washer onto FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Connect FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Speed Sensor 1 FIRST DEGREE FITNESS Apollo Pro V Rowing Machine - Frame Plug
Fit washer onto the new Sensor Connect the cables. Install the Speed Sensor as shown. Replace the Frame Plug.