Laserliner - logoCondense Spot XP
OhjekirjaLaserliner Condense Spot XPLaserliner Condense Spot XP 2

Laserliner Condense Spot XP - icon 2Read the operating instructions and the enclosed brochure „Guarantee and additional notices“ completely. Follow the instructions they contain. Safely keep these documents for future reference.

Toiminto/sovellus

The CondenseSpot is an infrared temperature measuring instrument with an integrated hygrometer that permits non-contact temperature measurements on surfaces as well as the measurement of relative humidity and ambient temperature. The instrument measures how much electromagnetic energy is emitted in the infrared wavelength range and uses this information to calculate surface temperature. During this process, two additional integrated sensors detect relative humidity and ambient temperature. The dew point is also calculated.

Laserliner Condense Spot XP - figure 1Laserliner Condense Spot XP 3

1 low battery charge 6 min/max and average measurement values
2 stability progress bar for relative
humidity measurement
7 dew point temperature (D Temp) and ambient temperature  (A Temp) in °C or °F
3 laser beam switched on, temperature measurement (infrared) 8 condense water indicator
4 measurements in °C or °F 9 last measurement value will be displayed brie y (7s)
5 relative humidity in % 10 replace battery

Laserliner Condense Spot XP 4Laserliner Condense Spot XP 5

Laser: The laser is a targeting aid to sight the location for the infrared measurement. Only the surface‘s temperature is measured. Laserliner Condense Spot XP 6

7. Displaying Min/Max/Avg, Ambient temperature, Dew point temperatureLaserliner Condense Spot XP 7

8. Dew point temperature is the temperature at which current air conditions would produce condensation. The CondenseSpot calculates the dew point temperature from ambient temperature, relative humidity, and ambient atmospheric pressure. In combination with the infrared thermometer, thermal bridges are easily detected. If the temperature of the measured location drops below the dew point, condensation (water) will form on the surface.Laserliner Condense Spot XP 8

9. Ilman suhteellinen kosteus
The relative humidity is indicated in relation to the maximum possible humidity (100 %) at which air forms water vapor. The ability of air to hold water is temperature-dependent. Thus humidity is the volume of water vapor in the air. The range for humidity is 0 … 100%. 100% = saturation point.
Under these conditions for temperature and atmospheric pressure, air cannot absorb any more water.Laserliner Condense Spot XP 9

When temperature fluctuations (± 1 °C) and/or changes to relative humidity (± 1%) are rapid, the sensor must adapt itself to the new conditions. An hourglass with a progress bar is displayed during this stabilization process.
During this process, displayed values are only approximations. Only after these symbols have been switched off is a stable value presented which represents maximum accuracy.

10. Setting the emission coef cientLaserliner Condense Spot XP 10

A built-in sensor head detects the material/surface-specific infrared rays emitted by every object. The level of these emissions is determined by the material‘s emission coefficient (0.01 to 0.99). This instrument is preset to an emission coefficient of 0.95, which is applicable to most organic materials as well as plastics,  ceramics, wood, rubber, and stone. For details of those materials with a different emission coefficient, please refer to the table.

Tuntematon päästökerroin:
Apply masking tape or black matt paint to the surface of the area whose temperature you wish to measure. Wait until the tape/paint has heated up.
The temperature of the surface can then be measured with an emission coefficient of 0.95.

11. Emission coef cient tables
Epämetallit

Asbesti 0.93 Kalkkikivi 0.98
Asvaltti 0.95 Marmori
Black, dull finish Greyish, polished
0.94
0.93
Basaltti 0.70
Tiilenpunainen 0.93
carborundum 0.90 Muuraus 0.93
Keramiikka 0.95 maali
Musta, matta
Heat-resistant White
0.96-0.98 0.92
0.85 -0.95
Kiina
Brilliant white With glaze
0.7 - 0.75 0.92
savi 0.95 Paperi
Kaikki värit
0.95-0.97
Coal Non-oxidised 0.8-0.9
Muovi
Translucent PE, P, PVC
0.95
0.94
Concrete, plaster, mortar 0.93
Puuvilla 0.77 Kumi
Kova
Pehmeä, harmaa
0.94-0.95 0.89
Keramiikka, matta 0.93
Kangas 0.95
Lasi 0.85 -0.94 Kvartsilasi 0.93
grafiitti 0.7 -0.8 Lumi 0.80
sora 0.95 maaperä 0.9 -0.98
Kipsi 0.8-0.95 terva 0.79 -0.84
Jäähdytyselementti Musta, anodisoitu 0.98 Tervapaperi 0.91 -0.93
Muuntaja maali 0.94
Ihmisen iho 0.98 Tapetti, vaalea 0.88-0.90
jää
Poista valinta
Kovalla pakkasella
0.97
0.98
vesi 0.93
Puu
hoitamaton
Pyökki, höylätty
0.8 - 0.95
Lime 0.3 -0.4
Lime maim brick 0.95

Metallit

Alloy A3003 Oxidised
Karhennettu
0.3
0.1 - 03
Rauta, taottu Matt 0.9
Johtaa
Karkea
Hapetettu
0.4
0.2 - 0.6
Aluminium Oxidised
Kiiltävä
0.2 - 0.4
0.04 - 0.06
Molybdenum Oxidised 0.2 - 0.6
Messinki
Kiiltävä
Hapetettu
0.3
0.5
Nickel Oxidised 0.2 - 0.6
Platina musta 0.9
Kupari
Hapetettu
Elect. terminal strips
0.4 - 0.8 0.6 Teräs
Cold rolled Ground plate
Kiillotettu levy
metalliseos (8 % nikkeliä,
18% chromium) Galvanised Oxidised
Voimakkaasti hapettunut
Freshly rolled Rough, flat surface
Ruosteinen, punainen
Sheet, nickel-plated Sheet, rolled
0.7 - 0.9 0.4 - 0.6 0.1
0.35
0.28
0.80
0.88
0.24
0.95- 0.98 0.69
0.11
0.56
Haynes Metal alloy 0.3 - 0.8
Inconel
Hapetettu
Sandblasted Electropolished
0.7 - 0.95 0.3 - 0.6 0.15
Rauta
Hapetettu
Ruosteen kanssa
With red rust
0.5-0.9 0.5-0.7 0.61-0.85
Rauta, valettu
Hapetettu
Non-oxidised
Sula massa
0.6 - 0.95 0.2
02 - 03
Zinc Oxidised 0.1

Tekniset tiedot

Technical revisions reserved. 08.13

Measured quantities °C (°F) infrared temperature measurement, %rH relative humidity, °C (°F) ambient temperature measurement
Infrared measurement range -40 °C … 350 °C (-40 °F … 662 °F)
Ambient temperature measurement range -10 °C … 60 °C (14 °F … 140 °F)
Relative humidity measurement range 20 % … 90 % rH
Dew point indicator -20 ° C… 60 ° C
Infrapuna tarkkuus t 1 °C (-10 °C … 60 °C); t 1.5 °C (< 10 °C and > 60 °C) or t 1.5 % whichever value is greater
Ambient temperature accuracy t 2 °C
Relative humidity accuracy t 3%
Infrared resolution 0.1 ° C
Relative humidity resolution 1%
Dew point resolution 1 ° C
Päästökerroin Adjustable, 0.10 … 0.99
Käyttölämpötila 0 ° C… 40 ° C
Säilytyslämpötila -20 ° C… 70 ° C
Optiikka 8:1 (distance: measured spot)
Laser aallonpituus 650 nm
Laser tyyppi Class 2, < 1 mW
Virtalähde Type 9 V E block battery

General safety instructions.
Attention: Do not look directly into the laser beam! The laser may not get into the hands of children! Do not point this device unnecessarily toward persons.Laserliner Condense Spot XP - warning

EU-direktiivit ja hävittäminen
Laserliner Condense Spot XP - ce
Tämä laite täyttää kaikki tarvittavat standardit tavaroiden vapaalle liikkuvuudelle EU:n sisällä.
Tämä tuote on sähkölaite ja se on kerättävä erikseen hävitettäväksi sähkö- ja elektroniikkalaiteromua koskevan eurooppalaisen direktiivin mukaisesti.
Lisää turvallisuus- ja lisähuomautuksia osoitteessa: www.laserliner.com/info
CondenseSpotLaserliner Condense Spot XP - CondenseSpot

Laserliner Condense Spot XP - iconPALVELU
Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Saksa
Puh.: +49 2932 638-300, Faksi: +49 2932 638-333
[sähköposti suojattu]
Umarex GmbH & Co KG
ukkonen kenttä 2
59757 Arnsberg, Saksa
Puh.: +49 2932 638-300, Faksi: -333
www.laserliner.com
Laserliner - logoLaserliner Condense Spot XP - ce

Asiakirjat / Resurssit

Laserliner Condense Spot XP [pdf] Käyttöopas
Condense Spot XP

Jätä kommentti

Sähköpostiosoitettasi ei julkaista.