- Product Name: Arc Flash Mini Pro Class 1 SRL-P
- Model Number: MSRD34 Rev B 0520245
- Languages: EN, ES, FR
- Weight Limit: ANSI limits the weight of fall protection
equipment users to a maximum of 310 lbs - Maximum Worker Weight for Tie-off: Up to 420 lbs
- Class 1 Free Fall: Maximum of 2 feet (0.6 m)
- Class 2 Free Fall: Maximum of 6 feet (1.8 m)
Product Usage Instructions
Warnings and Important Information
Ensure to read and understand the entire manual before using the equipment to prevent serious injury or death.|
Fall Arrest System Components
The system typically consists of an anchorage, a Full Body Harness (FBH), and a connecting device like a Shock Absorbing Lanyard (SAL) or a Self-Retracting Lanyard (SRL) attached to the dorsal D-ring of the FBH.
Fall Protection Plan
A Fall Protection Plan must be in place and available for review by all workers. Proper training in the use, maintenance, and storage of the equipment is essential. Training should be repeated regularly and not expose trainees to fall hazards.
FAQ
Q: Can heavy users exceed the weight limit specified by ANSI?
A: Heavy users exceeding the weight limit may face an increased risk of serious injury or death due to higher fall arrest forces.
Their ability to withstand falls is significantly affected by weight.
User Instruction Manual
Arc Flash Mini Pro Class 1 SRL-P
This manual is intended to meet the Manufacturer’s Instructions as required by the American National Standards Institute (ANSI) Z359 and should be used as part of an employee training program as required by the Occupational Safety and Health Administration (OSHA).
For purposes of this manual, the Arc Flash Mini Pro Class 1 SRL-P in all iterations may be referred to collectively as the 7’ Arc Flash Mini Pro, the Arc Flash Mini Pro, the Mini Pro, the SRL-P, the SRD, the SRL, the equipment, the device, the product, or the unit.
Throughout this manual, ANSI Z359.0-2012 fall protection words, phrases and terms are used. These terms are all formally defined in Section 9 of this manual.
Any non-English translations of this user instruction manual are for reference only.
Warnings and Important Information
WARNING
- Avoid moving machinery, thermal, electrical, and/or chemical hazards as contact may cause serious injury or death.
- Avoid swing falls.
- Follow the weight restrictions and recommendations in this manual.
- Remove from service any equipment subjected to fall arrest forces.
- Remove from service any equipment that fails inspection.
- Do not alter or intentionally misuse this equipment.
- Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual.
- Do not connect rebar hooks, large carabiners, or large snap hooks to the FBH dorsal D-rings as this may cause a roll-out condition and/or unintentional disengagement.
- Use caution when performing arc welding. Arc flash from arc welding operations, including accidental arcs from electrical equipment, can damage equipment and are potentially fatal.
- Examine the work area. Be aware of the surroundings and workplace hazards that may impact safety, security, and the functioning of fall arrest systems and components.
- Hazards may include, but are not limited to, cable or debris tripping hazards, equipment failures, personnel mistakes, or moving equipment such as carts, barrows, fork lifts, cranes, or dollies. Do not allow materials, tools, or equipment in transit to contact any part of the fall arrest system.
- Do not work under suspended loads.
IMPORTANT
This product is part of a personal fall arrest, restraint, work positioning, suspension, or rescue system. A Personal Fall Arrest System (PFAS) is typically composed of an anchorage and a Full Body Harness
(FBH), with a connecting device, i.e., a Shock Absorbing Lanyard (SAL), or a Self-Retracting Lanyard
(SRL), attached to the dorsal D-ring of the FBH.
These instructions must be provided to the worker using this equipment. The worker must read and understand the manufacturer’s instructions for each component or part of the complete system. Manufacturer’s instructions must be followed for proper use, care, and maintenance of this product. These instructions must be retained and be kept available for the worker’s reference at all times. Alterations or misuse of this product, or failure to follow instructions, may result in serious injury or death.
A Fall Protection Plan must be on file and available for review by all workers. It is the responsibility of the worker and the purchaser of this equipment to assure that users of this equipment are properly trained in its use, maintenance, and storage. Training must be repeated at regular intervals. Training must not subject the trainee to fall hazards.
Consult a doctor if there is reason to doubt your fitness to safely absorb the shock of a fall event. Age and fitness seriously affect a worker’s ability to withstand falls. Pregnant women or minors must not use this equipment.
ANSI limits the weight of fall protection equipment users to a maximum of 310 lbs. Products in this manual may have a rated capacity exceeding ANSI capacity limits. Heavy users experience more risk of serious injury or death due to falls because of increased fall arrest forces placed on the user’s body. In addition, the onset of suspension trauma after a fall event may be accelerated for heavy users.
The user of the equipment discussed in this manual must read and understand the entire manual before beginning work.
NOTE: For more information consult the ANSI Z359 body of standards.
Description
The FallTech Arc Flash Mini Pro SRL-P is a personal self-retracting device for those working at height and may be subject to fall hazards. This product is not suitable for applications with leading edge exposures where the lifeline of this device may come in contact with an edge during a fall event. Contact FallTech for more information or product selection questions. This manual includes one Appendix containing figures and tables specific to the Arc Flash Mini Pro SRL-P discussed in this manual.
FallTech Arc Flash SRLs have been tested to meet the requirements of ASTM F887 and OSHA 1910.269 requiring a capacity to maintain flame resistance during an electric arc with a heat energy of up to 40±5 cal/cm2. Please refer to the table in Appendix A of this supplement for specific part numbers and specifications.
The SRL discussed in this manual may be attached to an overhead anchorage, i.e., from directly over the user’s head, or to an anchorage at a maximum of 5’ below the user’s FBH dorsal D-ring for a worker weight up to 420 lbs. Below D-ring tie-off is outside the scope of ANSI Z359 and is only allowed when no edge hazards are present. At no point during a fall shall the lifeline be loaded over any edge.
As shown in Figure 1 below, the Arc Flash Mini Pro has a nylon housing that contains a synthetic lifeline wound onto a spring tensioned drum. The Arc Flash Mini Pro lifeline is equipped with an energy absorber and a leg-end connector. When the user is attached, the lifeline extends and retracts with the user movement, automatically maintaining taut lifeline. If a fall occurs, a centrifugal pawl system engages, stopping the lifeline payout. Then, the in-line Energy Absorber (EA) will deploy, gradually slowing and arresting the fall.
See Table 1A in Appendix A for product, material, and performance specifications.
Figure 1 – About the Arc Flash Mini Pro Class 1 SRL-P | |
1 | SRL-FBH Connector |
2 | Energy Absorber |
3 | Connector Assembly |
4 | Housing |
5 | Lifeline Stop |
6 | Synthetic Lifeline |
7 | Leg-End Connector |
American National Standards Institute (ANSI) and Occupational
Safety and Health Administration (OSHA):
The SRD discussed in this manual meets the standards of ANSI Z359.14-2021, ANSI A10.32-2012, and Occupational Safety and Health Administration (OSHA) regulations 1926.502 and 1910.140. ANSI requires SRDs be classified according to the type of usage the user would be exposed to, and are tested either as Class 1 or Class 2. Dynamic performance means that the SRD is installed in a testing drop tower. A test weight is attached to the SRD and then dropped. Test results are recorded.
Parameters recorded are:
- Arrest Distance (AD)
- Average Arrest Force (AAF)
- Maximum Arrest Force (MAF)
The Arrest Distance is the total vertical distance required to arrest a fall. The Arrest Distance includes the deceleration distance and the activation distance. The Average Arrest Force is the average of the forces applied to the body and the anchorage by the fall protection system. The Maximum Arrest Force is the maximum amount of force that may be applied to the body and the anchorage by the fall protection system. In addition to the above tests conducted in ambient conditions, the units must be for average and peak forces under certain environmental conditions, where the units are cooled, then tested, heated, then tested, or saturated in water and tested again. Separate units may be used for each test. All test results are recorded.
This test data is then used to establish the basis for fall clearance guidelines published in the user instruction manual.
Class 1 and 2: Class 1 devices shall be used only on overhead anchorages and shall be subjected to a maximum free fall of 2 feet (0.6 m) or less. Class 2 devices are intended for applications where an overhead anchorage may not be available or feasible and be subjected to a free fall of no more than 6 feet (1.8 m) over an edge.
To be declared a Class 1 and Class 2 device, ANSI requires an SRD to have an overhead Arrest Distance of less than 42” (1.1 m), an Average Arrest Force of less than 1,350 lbs (6 kN) [1,575 lbs (7 kN) conditioned] and a Maximum Arresting Force of 1,800 lbs (8 kN), for both ambient and conditioned testing.
When dynamically tested in accordance with requirements of ANSI Z359.14-2021, FallTech Class 1 and Class 2 Self-Retracting Devices have an AAF of 1,350 lbs (6 KN) or less and an AD of less than 42” (1.1 m).
Please see Section 5 of this user instruction manual for how to calculate your Minimum Required Fall Clearance (MRFC).
Please see Section 5.2 of this user instruction manual for how to calculate your Minimum Required Fall Clearance (MRFC) using the affixed labels.
Classification information found on product labels is based on test results. Table 1B in Appendix A provides test performance results forthe SRD discussed in this manual. NOTE: Arrest distance is one of several parts of the Minimum Required Fall Clearance (MRFC). MRFC is discussed in detail in Section 5 .
OSHA requires an SRD limit the free fall to 2 feet (0.9 m) or less. If the maximum free fall distance must be exceeded, the employer must document, based on test data, that the maximum arresting force will not be exceeded, and the personal fall arrest system will function properly. Contact Falltech for more information on this testing.
Application
Purpose:
The Arc Flash Mini Pro SRL-P is designed to be used as a component in a Personal Fall Arrest System (PFAS), to provide a combination of worker mobility and fall protection as required for inspection work, general construction, maintenance work, oil production, confined space work, etc.
Personal Fall Arrest System
A PFAS is an assembly of components and subsystems used to arrest a person during a fall event. A PFAS typically consists of an anchorage, a deceleration device such as a Energy Absorbing Lanyard
(EAL), a Self-Retracting Device (SRD), or a Fall Arrestor Connecting Subsystem (FACSS), and a properly fitted Full Body Harness (FBH). The SRD discussed in this manual may be used in non-overhead anchorage situations. Maximum permissible free fall in a typical PFAS is 6’ (1.8 m). Other applications may be below the D-ring, but no edge exposures are allowed with this product.
Horizontal Lifeline (HLL) and Rail Systems
The SRL may be attached to rigid and flexible anchors provided that all HLL or rail system applications, installation, and uses are under the supervision of a Qualified Person.
Rescue
Ensure a written rescue plan, method, and system is in place and readily available for rapid response. Rescues may require specialized equipment or measures. Rescue operations are beyond the scope of this manual. See ANSI Z359.4.
Application Limits
Take action to avoid moving machinery, abrasive surfaces, and thermal, electrical, including the arc from welding applications, and chemical hazards as contact may damage the SRL, which may result in serious injury or death. The SRL is not designed for use in restraint, personnel riding, suspension, or work positioning. Rescue applications are beyond the scope of this manual. Do not use the SRL for these applications except as a back-up PFAS.
System Requirements
Capacity:
The Arc Flash Mini Pro SRL-P is designed for use by a single user with a combined weight of user, tools, clothing, etc., of:
- 130 – 310 lbs. (59 – 141 kg) to comply with ANSI and OSHA
- 130 – 420 lbs. (59 – 191 kg) to comply with OSHA only
Compatibility Of Connectors:
Connectors are considered to be compatible with connecting elements when they have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms
to inadvertently open regardless of how they become oriented. Contact FallTech if you have any questions about compatibility. Connectors must be compatible with the anchorage or other system components. Do not use equipment that is not compatible, see Figure 2. Non-compatible connectors may unintentionally disengage. Connectors must be compatible in size, shape, and strength. Self-closing, and self-locking connectors are required by ANSI and OSHA.
Compatibility Of Components:
Equipment is designed for use with approved components and subsystems only. Substitutions or replacements made with non-approved components or subsystems may jeopardize compatibility of equipment and may affect the safety and reliability of the complete system.
Making Connections:
Only use self-locking connectors with this equipment. Only use connectors that are suitable to each application. Ensure all connections are compatible in size, shape, and strength. Do not use equipment that is not compatible. Visually ensure all connectors are fully closed and locked. Connectors are designed to be used only as specified in each product’s user instructions.
Figure 2 – Non-Compatible Connections | |
A | Never connect two active components (snap hooks or carabiners) to each other. |
B | Never connect two active components (snap hooks or carabiners) to a single D-ring at the same time. |
C | Never connect in a way that would produce a condition of loading on the gate. |
D | Never attach to an object in a manner whereby the gate (of the snap hook or carabiner) would be prevented from fully closing and locking. Always guard against false connections by visually inspecting for closure and lock. |
E | Never attach explicitly to a constituent subcomponent (webbing, cable or rope) unless specifically provided for by the manufacturer’s instructions for both subcomponents (snap hook or carabiner and webbing, cable, or rope). |
F | Never attach in a manner where an element of the connector (gate or release lever) may become caught on the anchor thereby producing additional risk of false engagement. |
G | Never attach a spreader snap hook to two side/positioning D-rings in a manner whereby the D-rings will engage the gates; the gates on a spreader must always be facing away from the D-rings during work positioning. |
Personal Fall Arrest System:
A PFAS is an assembly of components and subsystems used to arrest a person during a fall event. A PFAS is typically composed of an anchorage and a FBH, with an energy absorbing connecting device, i.e., an SAL, an SRL, or a Fall Arrester Connecting Subsystem (FACSS), connected to the dorsal D-ring of the FBH. PFAS components used in conjunction with this SRL should comply with ANSI Z359 requirements and applicable OSHA regulations.
Average Arrest Force and Arrest Distance:
Table 1B in Appendix A provides test data on typical performance attributes of the three principal parameters: Arrest Distance, Average Arrest Force, and Maximum Arrest Force, listed by model number and class. Testing is conducted under various environmental conditions, at ambient temperature, hot, cold, and wet conditions. In manufacturer’s tests, worst case performance attributes of the SRL, connected at maxmimum below dorsal D-ring tie-off by user weight in non-Leading Edge applications are:
5’ Below D-Ring, Non-Leading Edge | 130 to 310 lbs. (59 to 141 kg) | 310 to 420 lbs. (141 to 191 kg) |
Longest Arrest Distance | 114” (2.9 m) | 154” (3.9 m) |
Largest Average Arrest Force | 852 lbs (3.8 kN) | 742 lbs (3.3 kN) |
Largest Maximum Arrest Force | 1,315 lbs (5.9 kN) | 1,092 lbs (4.9 kN) |
The Competent Person may find this data useful with planning anchorage location and calculating fall arrest loads and distances from the walking/working level to the nearest obstruction or lower level. See Section 5.
NOTE: Arrest distance is one part of the Minimum Required Fall Clearance (MRFC). The MRFC is determined by consideration of multiple factors in fall protection. Attachment below the level of the FBH D-ring will require additional fall clearance. MRFC is discussed in detail in Section 5.
Personal Fall Arrest System Anchorage Strength:
An anchorage selected for PFAS application must have the strength to sustain a static load applied in the direction permitted by the PFAS of at least:
- Two times the maximum arrest force permitted when certification exists, or
- 5,000 lbs. (22.2 kN) in the absence of certification.
Select an anchorage location carefully. Consider structural strength, obstructions in the fall path, and swing fall hazards. In certain situations, the Qualified Person can determine that a given structure is able to withstand the applied MAF of the PFAS with a safety factor of at least two, as required by OSHA.
Installation and Use
WARNING
Do not alter or intentionally misuse this equipment. Consult FallTech when using this equipment in combination with components or subsystems other than those described in this manual. All components or subsystems used with the SRD discussed in this manual must be in compliance with ANSI Z359 and/or OSHA.
Do not use rebar hooks, large carabiners or large snap hooks to connect to the FBH dorsal
D-rings or to any small diameter non-compatible anchor point as this may cause a roll-out condition and/or unintentional disengagement.
Avoid sharp and/or abrasive surfaces and edges.
Installation to Full Body Harness
Installation for both Single-leg and Twin-leg configurations of the Arc Flash Mini Pro SRL-P follow the same steps listed below:
- Step 1: On the FBH, lift the dorsal D-ring to the up-pointing position, then loosen the intersection of the two web straps that pass through the D-ring slot to create slacked loops of about 2” as shown in Figure 3A. Note that some harnesses may have a built-in tunnel.
- Step 2: Depress both release buttons and slide the locking bar into the open position as shown in Figure 3B.
- Step 3: Attach the connector to the slacked loops by inserting the locking bar through the slacked loops as shown in Figure 3C.
- Step 4: Make sure the locking bar is in the fully inserted and in the locked position, see Figure 3D.
Attaching to an Anchorage
Examine the work area for possible hazards. Take caution to avoid overhead hazards such as cranes, poles, overhead power cables, and walking/working surface hazards such as power cables, welding leads, air and fluid hoses, including obstruction hazards such as vertical columns and stacks of materials on the lower level. Eliminate hazards where possible.
Ensure the anchorage provides the Minimum Required Fall Clearance (MRFC) in the fall path below the walking/working surface to prevent striking the lower level or an obstruction during a fall event. Take action to avoid swing falls, which occur when the anchorage is not directly above the point where the fall occurs.
Fall clearance and swing falls are subject to variable conditions. Anchor height, lateral movement, and setback distance all affect anchor location with regard to fall clearance and swing falls.
The SRL may be attached to an overhead anchor, i.e., above the user’s FBH dorsal D-ring, or a non-overhead anchor, i.e., below the user’s FBH dorsal D-ring. A non-overhead anchor may be a maximum of 5’ (1.5 m) below the user’s FBH dorsal D-ring for a worker weighing 130 to 420 lbs (59 to 191 kg). Non-overhead anchor locations result in greater possibility of edge hazards. At no point during a fall shall the lifeline be loaded over any edge. Use of a below D-ring anchorages should be as a last resort, when no other anchor option exists. When anchored below the FBH back D-ring, fall events will result in greater fall clearances.
Using the Arc Flash Mini Pro SRL-P
Before each use, inspect the Arc Flash Mini Pro in accordance with Section 7. Remove the device from service if the inspection shows damage or any malfunction.
Don the FBH and/or attach the SRL in accordance with the harness manufacturer’s instructions.
Follow the instructions contained in this manual and on the labels. Failure to follow instructions may result in serious injury or death.
Connect the leg-end connector to an approved anchorage point or to the full body harness depending on orientation. Ensure the connector closes and locks. Ensure all connections are compatible. Normal operation will allow the working length of the lifeline to extend and retract as the worker moves about.
Avoid sudden or quick movements during the normal work operation, as this may cause the SRL pawl system to engage and possibly cause loss of balance, which may cause injury or death. If a fall occurs, the pawl system will engage and lock the lifeline. The EA will deploy to arrest the fall and limit arrest forces on the user.
Locking Mechanism
The SRD utilizes an acceleration based locking mechanism. The locking function requires a certain payout rate during a fall event to function correctly. Certain situations, confined or cramped spaces, shifting footing such as sand, gravel, grain, or a sloped surface may not allow the lifeline to reach sufficient speed to activate the lock mechanism. A clear path is required to assure positive locking of the SRD. Ensure the lock is functioning properly. Pull the lifeline out a short distance and give it a sharp tug. The lifeline must lock. If it fails to lock, remove it from service immediately. Ensure the work zone remains within stated parameters.
Visual Indicator
The primary visual indicator is the shear connector. The shear connector halves will separate if the SRL-P has been subjected to fall arrest forces, as shown in Figure 4, Image B. If the shear connector is separated, remove the unit from service. For deployed visual indicators, both SRDs and the energy absorber shall be removed from service and destroyed. SRD units shall not be salvaged and re-used with other energy absorber(s).
After A Fall
Ensure a written rescue plan, method and system is in place and readily available to all users for rapid response. Ensure all users are trained in rescue procedures. If a fall event occurs, remove it from service, and store it separately. Remove from service any unit that has been subjected to fall arrest forces or that exhibits damage consistent with such forces. For questions, contact FallTech.
Using the SRD
Do not use the SRD if inspection shows damage or any malfunction. Don the FBH in accordance
with the FBH manufacturer’s instructions. Follow the instructions contained in this manual and on the labels. Failure to follow instructions may result in serious injury or death. Connect the SRL-FBH Connector to the dorsal D-ring on the FBH. Ensure the connector closes and locks. Attach the leg-end carabiner to the chosen anchorage and ensure the leg-end connector closes and locks. Ensure all connections are compatible. Normal operation will allow the working length of the lifeline to extend and retract as the worker moves about. A certain amount of tension must remain on the web at all times to ensure proper operation of the internal brake. Do not allow the lifeline to become slack.
If the lifeline becomes slack, remove the SRD from service for inspection. See Section 7.
Avoid sudden or quick movements during the normal work operation, as this may cause the SRD brake to engage and possibly cause loss of balance and injury or death.
If a fall occurs, the brake will engage and lock the lifeline. The EA will deploy to arrest the fall and limit arrest forces on the user.
- DO NOT extend the lifeline past the operational limit.
- DO NOT allow one SRD lifeline to become tangled or twisted with another SRD lifeline during use.
- DO NOT allow any lifeline to pass under arms or between legs during use.
- DO NOT clamp, knot, or prevent the lifeline from retracting or being taut.
- DO NOT lengthen the SRD by connecting a lifeline or similar component.
- DO NOT allow the lifeline to remain outside the housing when not in use.
Calculating Minimum Required Fall Clearance
Arc Flash Mini Pro in Overhead, Non-Leading Edge Anchorage Application
[130 to 310 lbs. (59 to 141 kg) user]
The Arc Flash Mini Pro may be used may be used as a standard SRD in an overhead condition, in which the SRD is installed anywhere in the allowable attachment area, which ranges from directly above the user to level with the FBH D-ring, as shown in Figure 5.
The overhead condition minimum required fall clearance (MRFC) is calculated using four metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and Harness Stretch [1 ft (0.3m)], Safety Factor [1.5 ft (0.5m)], and Swing Fall. The diagram in Figure 6 is calculated using the performance data of the SRD and includes all four metrics listed previously to determine the MRFC.
Arc Flash Mini Pro with a Non-Overhead, Non-Leading Edge Anchorage Application [130 to 310 lbs. (59 to 141 kg) user]
The non-leading edge below D-ring condition minimum required fall clearance (MRFC) is calculated using five metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and Harness Stretch [1 ft (0.3m)], Safety Factor [1.5 ft (0.5m)], Dorsal D-ring Height [5 ft (1.5m)], and Swing Fall. Dorsal D-ring height is added to account for the below D-ring tie-off compared to the overhead condition. The diagram in Figure 6 is calculated using the performance data of the SRD and includes all five metrics listed previously to determine the MRFC. Below D-ring tie-off is outside the scope of ANSI Z359 and is only allowed when no edge hazards are present. At no point during a fall shall the lifeline be loaded over any edge.
Arc Flash Mini Pro in Overhead, Non-Leading Edge Anchorage Application
[130 to 420 lbs. (59 to 191 kg) user]
The Arc Flash Mini Pro may be used may be used as a standard SRD in an overhead condition, in which the SRD is installed anywhere in the allowable attachment area, which ranges from directly above the user to level with the FBH D-ring, as shown in Figure 7.
The overhead condition minimum required fall clearance (MRFC) is calculated using four metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and Harness Stretch [1 ft (0.3m)], Safety Factor [1.5 ft (0.5m)], and Swing Fall. The diagram in Figure 8 is calculated using the performance data of the SRD and includes all four metrics listed previously to determine the MRFC.
Arc Flash Mini Pro with a Non-Overhead, Non-Leading Edge Anchorage Application
[130 to 420 lbs. (59 to 191 kg) user]
The non-leading edge below D-ring condition minimum required fall clearance (MRFC) is calculated using five metrics, measured from the walking-working surface: SRD Deceleration Distance, D-Ring Shift and Harness Stretch [1 ft (0.3m)], Safety Factor [1.5 ft (0.5m)], Dorsal D-ring Height [5 ft (1.5m)], and Swing Fall. Dorsal D-ring height is added to account for the below D-ring tie-off compared to the
overhead condition. The diagram in Figure 8 is calculated using the performance data of the SRD and includes all five metrics listed previously to determine the MRFC. Below D-ring tie-off is outside the scope of ANSI Z359 and is only allowed when no edge hazards are present. At no point during a fall shall the lifeline be loaded over any edge.
Maintenance, Service, and Storage
Maintenance:
Ensure the SRL is kept free of excess paint, grease, dirt or other contaminants as this may cause
the lifeline or retracting mechanism to malfunction. Ensure no debris enters the housing. Clean the exterior of the unit as required with a detergent/water solution. Do not allow water or other corrosion causing elements to enter the housing. After cleaning, pull the lifeline all the way out, allow the unit to air dry, then retract the lifeline into the unit. Clean labels as required.
DO NOT use heat to dry.
DO NOT attempt to disassemble the SRL.
Service
Remove the unit from service if it has been subjected to fall arrest force. Tag the unit as “UNUSABLE” to prevent future use. The SRD is not repairable.
Storage
Store the Arc Flash Mini Pro in a cool, dry, clean environment out of direct sunlight. Position the SRL so excess water can drain out. Avoid exposure to chemical or caustic vapors. Thoroughly inspect the SRL after any period of extended storage.
Inspection
Pre-Use User Inspection
Perform an inspection before each use in accordance with the recommendations in Table 1 below.
Table 1 – Guidelines for Arc Flash Mini Pro SRL-P Inspection | ||
Inspection | Pass | Fail |
The web lifeline should extract and retract completely and without faltering and should remain taut under tension without sagging. | ||
Extract the web lifeline several inches and apply a firm pull to confirm the SRD locks. The locking should be certain and without skidding. Repeat this lockup at additional places along the lifeline length to confirm the SRD is operating correctly. | ||
Examine the energy absorber on the lifeline to be certain that it has not been activated. | ||
Review the web lifeline closely for wear created by abrasion, tattered yarns, unraveled strands, burns, and cuts. Also examine for knots, rust, dirt, paint, and grease or oil. Check for damage caused by chemical corruption or excessive heat as evident with discoloration. Examine for extreme exposure to sunlight and ultraviolet as demonstrated by desiccation. | ||
Check for any missing or loose screws or nuts and any deformed or damaged components. | ||
Examine the external housing for cracks, breaks, or warping. | ||
Review the integral anchor loop and Connector for damage and deformation. The anchor loop should rotate smoothly and be joined firmly to the housing. The Connector should also rotate smoothly within the anchor loop. | ||
Examine the overall SRD unit for any indications of deterioration or damage. | ||
All labels must be intact and totally readable (see Section 8) |
If an inspection reveals defects or damage to the equipment, remove the equipment from service.
Inspection Frequency:
Inspection by a competent person at regular intervals is required. The competent person will use the information in Table 2, SRL Inspection Recommendations, to determine the inspection frequency. Use Table 2 to determine the inspection frequency. Inspection by a factory authorized inspection entity at regular intervals is also recommended.
Table 2 – ANSI Z359.14-2021 SRL Inspection Recommendations | |||
Type of Use | Application Examples | Conditions of Use | Inspection Frequency Competent Person |
Infrequent to Light Use | Rescue and Confined Space, Factory Maintenance | Good Storage Conditions, Indoor or Infrequent Outdoor use, Room Temperature, Clean Environments | Annually |
Moderate to Heavy Use | Transportation, Residential Construction, Utilities, Warehouse | Fair Storage Conditions, Indoor and extended outdoor use, All temperatures, Clean or dusty environments | Semi-annually to Annually |
Severe to Continuous Use | Commercial Construction, Oil and Gas, Mining | Harsh Storage Conditions, Prolonged or Continuous outdoor Use, all temperatures, Dirty environments | Quarterly to Semi-annually |
Inspection Checklist:
Use Table 1: Guidelines for Cable SRL Inspection to inspect the SRL.
Inspection Results:
If an inspection reveals defects in or damage to the equipment, inadequate maintenance, or activated fall indicators, remove the equipment from service.
Inspection Document:
Record inspection results on the Inspection Record provided below or on a similar document.
Inspection Record | |||||
Model #: Serial #: Date of Manufacture: | |||||
INSPECTION DATE | INSPECTOR | COMMENTS | PASS/ FAIL | CORRECTIVE ACTION NEEDED | APPROVED BY |
Labels
Product labels must be present and legible.
Definitions
The following are general definitions of fall protection terms as defined by ANSI Z359.0-2012.
- Anchorage: A secure connecting point or a terminating component of a fall protection system or rescue system capable of safely supporting the impact forces applied by a fall protection system or anchorage subsystem.
- Anchorage Connector: A component or subsystem that functions as an interface between the anchorage and a fall protection, work positioning, rope access or rescue system for the purpose of coupling the system to the anchorage.
- Arrest Distance: The total vertical distance required to arrest a fall. The arrest distance includes the deceleration distance and activation distance.
- Authorized Person: A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard.
- Available Clearance: The distance from a reference point, such as the working platform, to the nearest obstruction that an authorized person might contact during a fall which, if struck, could cause injury.
- Capacity: The maximum weight that a component, system or subsystem is designed to hold.
- Certification: The act of attesting in writing that the criteria established by these standards or some other designated standard have been met.
- Certified Anchorage: An anchorage for fall arrest, positioning, restraint or rescue systems that a qualified person certifies to be capable of supporting the potential fall forces that could be encountered during a fall.
- Clearance: The distance from a specified reference point, such as the working platform or anchorage of a fall arrest system, to the lower level that a worker might encounter during a fall.
- Clearance Requirement: The distance below an authorized person that must remain clear of obstructions in order to ensure that the authorized person does not make contact with any objects that would cause injury in the event of a fall.
- Competent Person: An individual designated by the employer to be responsible for the immediate supervision, implementation and monitoring of the employer’s managed fall protection program who, through training and knowledge, is capable of identifying, evaluating and addressing existing and potential fall hazards, and who has the employer’s authority to take prompt corrective action with regard to such hazards.
- Component: An element or integral assembly of interconnected elements intended to perform one function in the system.
- Connecting Subsystem: An assembly, including the necessary connectors, comprised of all components, subsystems, or both, between the anchorage or anchorage connector and the harness attachment point.
- Connector: A component or element that is used to couple parts of the system together.
- Deceleration Distance: The vertical distance between the user’s fall arrest attachment at the onset of fall arrest forces during a fall, and after the fall arrest attachment comes to a complete stop.
- Energy (Shock) Absorber: A component whose primary function is to dissipate energy and limit deceleration forces which the system imposes on the body during fall arrest.
- Fall Arrest: The action or event of stopping a free fall or the instant where the downward free fall has been stopped.
- Fall Hazard: Any location where a person is exposed to a potential free fall.
- Free Fall: The act of falling before a fall protection system begins to apply forces to arrest the fall.
- Free Fall Distance: The vertical distance traveled during a fall, measured from the onset of a fall from a walking working surface to the point at which the fall protection system begins to arrest the fall.
- Harness, Full Body: A body support designed to contain the torso and distribute the fall arrest forces over at least the upper thighs, pelvis, chest and shoulders.
- Horizontal Lifeline: A component of a horizontal lifeline subsystem, consisting of a flexible line with connectors or other coupling means at both ends for securing it horizontally between two anchorages or anchorage connectors.
- Horizontal Lifeline Subsystem: An assembly, including the necessary connectors, comprised of a horizontal lifeline component and, optionally, of: a) An energy absorbing component or, b) A lifeline tensioner component, or both. This subsystem is normally attached at each end to an anchorage or anchorage connector. The end anchorages have the same elevation.
- Lanyard: A component consisting of a flexible rope, wire rope or strap, which typically has a connector at each end for connecting to the body support and to a fall arrester, energy absorber, anchorage connector or anchorage.
- Lanyard Connecting Subsystem: An assembly, including the necessary connectors, comprised of a lanyard only, or a lanyard and energy absorber.
- Personal Fall Arrest System (PFAS): An assembly of components and subsystems used to arrest a person in a free fall.
- Positioning: The act of supporting the body with a positioning system for the purpose of working with hands free.
- Positioning Lanyard: A lanyard used to transfer forces from a body support to an anchorage or anchorage connector in a positioning system.
- Qualified Person: A person with a recognized degree or professional certificate and with extensive knowledge, training and experience in the fall protection and rescue field who is capable of designing, analyzing, evaluating and specifying fall protection and rescue systems.
- Self-Retracting Device (SRD): A device that contains a drum wound line that automatically locks at the onset of a fall to arrest the user, but that pays out from and automatically retracts onto the drum during normal movement of the person to whom the line is attached.
- Snaphook: A connector comprised of a hook-shaped body with a normally closed gate or similar arrangement that may be opened to permit the hook to receive an object and, when released, automatically closes to retain the object.
- Swing Fall: A pendulum-like motion that occurs during and/or after a vertical fall. A swing fall results when an authorized person begins a fall from a position that is located horizontally away from a fixed anchorage.
APPENDIX A
Table 1B: Arc Flash Mini Pro Class 1 SRL-P ANSI/OSHA Performance Attributes | ||||||||||
Part #s and Conditions | Typical Performance for 130 to 310 lbs. (59-141 kg) User | Typical Performance for 130 to 420 lbs. (59-191 kg) User | ANSI Performance Requirements 130 to 310 lbs. (59-141 kg) User | |||||||
Part # | Anchorage Condition | Arrest Distance | Average Arrest Force | Maximum Arrest Force | Arrest Distance | Average Arrest Force | Maximum Arrest Force | Maximum Arrest Distance | Average Arrest Force *Conditioned | Maximum Arrest Force |
All Part Numbers in Table 1A |
Overhead Non-Leading Edge (ANSI Z359.14- 2021) |
42” (1.1 m) |
860 lbf. (3.7 kN) |
1,426 lbf. (6.3 kN) |
48” (1.2 m) |
723 lbf. (3.2 kN) |
1,323 lbf. (5.9 kN) |
42” (1.1 m) |
1,575 lbf. (7.0 kN) |
1,800 lbs. (8 kN) |
5’ Below D-Ring, Non-Leading Edge Condition (OSHA) |
114” (2.9 m) |
852 lbf. (3.8 kN) |
1,315 lbf. (5.9 kN) |
154” (3.9 m) |
742 lbf. (3.3 kN) |
1,092 lbf. (4.9 kN) |
N/A |
N/A |
Documents / Resources
![]() | FALLTECH Arc Flash Mini Pro Class 1 SRL-P Hook [pdf] Instruction Manual MSRD34_REV_B_052024_EN_ES_FR_BOOKLET.pdf, MSRD34 Rev B 0520245 EN ES FR 1, Arc Flash Mini Pro Class 1 SRL-P Hook, Arc Flash, Arc Flash Hook, Mini Pro Class 1 SRL-P Hook, Mini Pro Hook, Class 1 SRL-P Hook, SRL-P Hook, SRL-P, Hook |