FAHRENHEAT FUH Garage/Utility Heater User Guide Rugged, Heavy Duty – Industrial grade unit heater Plate-finned element design –…
Specifications
FUH 54C
Heater Rating and Voltage | BTU per Hr. | Phase | Contactor Built-in | Mounting Height, ft. (mm) | Min. Distance from Horizontal Air Throw, ft. (mm) | Mounting Hole to Wall, in (mm) | ||||
Vertical Installation | Horizontal Installation | |||||||||
Min. | Max. | Min. | Max. | |||||||
*5000 W @ 240V | 17,065 | |||||||||
1 | No | 6’ | 11’ | 6’ | 8’ | 18’ | **13” | |||
4165W @ 240V | 14,215 | |||||||||
3332W @ 240V 2500W @ 240V | 11,365 8,533 | (1829) | (3353) | (1829) | (2438) | (5472) | (330) | |||
*3750W @ 208V | 12,799 | |||||||||
1 | No | 6’ | 11’ | 6’ | 8’ | 18’ | **13” | |||
3123W @ 208V | 10,659 | |||||||||
2500W @ 208V 1874W @ 208V | 8,533 6,396 | (1829) | (3353) | (1829) | (2438) | (5472) | (330) |
FUH 724A
Heater Rating and Voltage | BTU per Hr. | Phase | Contactor Built-in | Mounting Height, ft. (mm) | Min. Distance from Horizontal Air Throw, ft. (mm) | Mounting Hole to Wall, in (mm) | ||||
Vertical Installation | Horizontal Installation | |||||||||
Min. | Max. | Min. | Max. | |||||||
*7500 W @ 240V | 25,598 | |||||||||
1 | No | 6’ | 11’ | 6’ | 8’ | 18’ | **13” | |||
6250W @ 240V | 21,331 | |||||||||
5000W @ 240V 3750W @ 240V | 17,065 12,799 | (1829) | (3353) | (1829) | (2438) | (5472) | (330) | |||
*5625W @ 208V | 19,198 | |||||||||
1 | No | 6’ | 11’ | 6’ | 8’ | 18’ | **13” | |||
4685W @ 208V | 15,990 | |||||||||
3750W @ 208V 2812W @ 208V | 12,799 9,598 | (1829) | (3353) | (1829) | (2438) | (5472) | (330) |
Heater is shipped from factory wired for these wattages. Heater can be field adjusted to the other wattages (Refer to Table 2 “Adjusting the Heat Output”.)
48″ (1219 mm) when heater air flow is between 45° downward and vertical.
WARNING
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-SONS, INCLUDING THE FOLLOWING:
SAVE THESE INSTRUCTIONS
WARNING: To prevent a possible fire, injury to persons or damage to the heater, adhere to the following:
Unpacking Your New Heater
Remove the heater from the box and inspect it for any damage. If it appears to be damaged, immediately return it to the store from which you purchased it.
Tools Needed
You will need the following tools to install your FUH Series electric heater:
Hardware Needed
You will also need the following hardware for installation:
NOTE: For certain applications, conduit may be required (see Figure 2). Check local electrical codes. If wiring is run in conduit, be sure there is enough flexible conduit to allow the heater to be turned if necessary.
Locating the Heater
The heater should be installed out of traffic areas and at least 6′ off the floor. The direction of air flow should not be restricted (ie: by columns or machinery) and the air flow should wipe exposed walls, rather than blowing directly at them. When more than one heater is used in an area, the heaters should be arranged so that the air discharge of each heater supports the air flow of the others to provide best circulation of warm air, as indicated in Figure 3, below.
Figure 3
Mounting
Wiring
WARNING: TO PREVENT POSSIBLE ELECTRIC SHOCK, DISCONNECT POWER TO THE HEATER AT THE MAIN SERVICE BOX BEFORE ATTEMPTING TO ADJUST THE HEAT OUTPUT OF THIS UNIT.
Adjusting the Heat Output
Heat output can be increased or decreased by switching wires at the wattage change terminal board. The heater is factory wired at the maximum rated BTU per hour. Should your particular application require less heat output, refer to Table 2 below and change the wires at the wattage change terminal board as shown in Wiring Diagram Figure 7A or 7B.
Table 2 – Heat Output Adjustments FUH54C
BTU/HR | VOLTS | WATTS | MAXFUSE SIZE | HEATER AMPS | MOVE JUMPERS FROM C-D TO A-B |
17065 | 240 | 5000 | 30 | 20.9 | NONE |
14215 | 240 | 4165 | 25 | 17.4 | BLUE |
11365 | 240 | 3332 | 20 | 13.9 | BLUE & YELLOW |
8533 | 240 | 2500 | 15 | 10.4 | BLUE, YELLOW & RED |
12799 | 208 | 3750 | 25 | 18.0 | NONE |
10659 | 208 | 3123 | 20 | 15.0 | BLUE |
8533 | 208 | 2500 | 15 | 12.0 | BLUE & YELLOW |
6396 | 208 | 1874 | 15 | 9.0 | BLUE, YELLOW & RED |
FUH724A
BTU/HR | VOLTS | WATTS | MAX FUSE SIZE | HEATER AMPS | MOVE JUMPERS FROM C-D TO A-B |
25,598 | 240 | 7,500 | 45 | 31.3 | NONE |
21,331 | 240 | 6,250 | 35 | 26.1 | BLUE |
17,065 | 240 | 5,000 | 30 | 20.9 | BLUE & YELLOW |
12,799 | 240 | 3,750 | 20 | 15.7 | BLUE, YELLOW & RED |
19,198 | 208 | 5,625 | 40 | 27.1 | NONE |
15,990 | 208 | 4,685 | 30 | 22.3 | BLUE |
12,799 | 208 | 3,750 | 25 | 18.1 | BLUE & YELLOW |
9,598 | 208 | 2,812 | 20 | 13.6 | BLUE, YELLOW & RED |
Figure 7B – Wiring Diagram FUH724A
Automatic Fan Delay: The FUH Series has an automatic fan delay. When the thermostat calls for heat, fan action is delayed momentarily until the heating elements warm. This prevents the circulation of cold air. When the heater raises the temperature of the room to the thermostat set point, the heating element is turned off but the fan will continue to run until the heating element cools down. This prevents exposing the unit to residual heat, provides a higher comfort level and prolonged element life.
Automatic Thermal Limit: FUH Series is equipped with a thermal limit which will automatically shut off the heater in the event of overheating. Should the thermal limit activate an alarm light will be visible on the front of the heater next to the thermo-stat knob. The heater will turn on when the operating temperature returns to normal. Should the unit overheat and activate the thermal limit, the cause of the overheating should be determined before further operation.
WARNING: DO NOT TAMPER WITH OR BYPASS ANY SAFETY LIMITS INSIDE HEATER.
CAUTION: CAUTION – DO NOT CONTINUE TO ATTEMPT TO USE THE HEATER IF THE THERMAL LIMIT REPEATEDLY OPERATES. TO DO SO COULD PERMANENTLY DAMAGE THE HEATER OR CREATE A FIRE OR SAFETY HAZARD.
NOTE: If the unit is installed in an area where the temperature is below 50° F, the fan may cycle on and off until the temperature in the room rises above 50° F, this is normal and does not indicate a problem with the unit. As soon as the heater warms the air in the room above 50°, the fan will operate continually until the thermostat has reached the room set point.
Adjusting Air Flow Direction
You can adjust the direction of air flow by:
It is important to keep this heater clean. Your heater will give you years of service and comfort with only minimum care. To assure efficient operation follow the simple instructions below.
WARNING: ALL SERVICING BEYOND SIMPLE CLEANING THAT REQUIRES DISASSEMBLY SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL.
TO REDUCE RISK OF FIRE AND ELECTRIC SHOCK OR INJURY, DISCONNECT ALL POWER COMING TO HEATER AT MAIN SERVICE PANEL AND CHECK THAT THE ELEMENT IS COOL BEFORE SERVICING OR PERFORMING MAINTENANCE.
User Cleaning Instructions:
Maintenance Cleaning Instructions:
(To be performed only by Qualified Service Personnel)
At least annually, the heater should be cleaned and serviced by a qualified service person to assure safe and efficient operation. After completing the cleaning and servicing, the heater should be checked for proper operation.
LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation.
The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marlet Engineered Products. Within the limitations of this warranty, inoperative units should be returned to Marley, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products.
THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT.
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products.
HOW TO OBTAIN WARRANTY SERVICE AND WARRANTY PARTS PLUS GENERAL INFORMATION
Note: When obtaining service always have the following:
Fahrenheat FUH 54C FUH Electric Garage Heater [pdf] Instruction Manual FUH 54C, FUH Electric Garage Heater, Electric Garage Heater, Garage Heater, FUH 54C, Heater |
365+ 5-Piece Cookware Set IKEA 365+ English Before using for the first time · Wash,…
43193783 Beach Cabana Deluxe Stripe KMART - SUMMER 23 - PACKAGING REVIEW. MATERIAL LABEL STITCHED…
6563095838743 Retractable Manual Awning 200cm beige Retractable Manual Awning 2.0M Store banne retractable 2.0M Einziehbare…
DWS-ECHO-CDL-01-US Echo Chandelier US Installation Guide DAVID WEEKS FOR TALA Thoughtful lighting, responsibly designed in…
AOT001 Orbit Acaia Orbit User Manual AOT001 FW 1.0.000 Contents 3 Introduction 4 Safety Information…
Capsule3 Pro Wireless Earbuds English English English English English English Capsule3 Pro 018-220385 IC ID:…