User Manual for Advantage Controls models including: BF-02-D-X Bypass Feeder, BF-02-D-X, Bypass Feeder, Feeder

M-Bypass Feeder

advantagecontrols.com - /downloads/pdf/

Download


File Info : application/pdf, 8 Pages, 2.44MB

PDF preview unavailable. Download the PDF instead.

M-Bypass Feeder-1
Manual
Bypass Feeder
Chemical Addition and Filtering
Installation Maintenance Repair Manual

Advantage Controls 4700 Harold-Abitz Dr. Muskogee, OK 74403 Phone: (800) 743-7431 Fax: (888) 686-6212 www.advantagecontrols.com email: support@advantagecontrols.com

08/2024

Table of Contents

I.

Introduction .....................................................................................3

Model Numbering............................................................................3

II.

Safety Considerations .....................................................................4

III.

Installation .......................................................................................4

A. Flow and Pressure Differential ............................................4

B. Flowrate...............................................................................4

C. Pressure Differential ............................................................4

D. Temperature ........................................................................4

Installation Drawings .......................................................................5

IV.

Optional Kits and Parts ...................................................................5

V.

Maintenance ....................................................................................6

A. Replacement Parts..............................................................6

VI.

Troubleshooting Guide ....................................................................7

Manufacturer's Product Warranty
Advantage Controls warrants bypass feeders of its manufacture to be free of defects in material or workmanship. Liability under this policy extends for 12 months from date of installation. Liability is limited to repair or replacement of any failed feeder or part proven defective in material or workmanship upon manufacturer's examination. Removal and installation costs are not included under this warranty. Manufacturer's liability shall never exceed the selling price of equipment or part in question. Advantage disclaims all liability for damage caused by its products by improper installation, maintenance, use or attempts to operate products beyond their intended functionality, intentionally or otherwise, or any unauthorized repair. Advantage is not responsible for damages, injuries or expense incurred through the use of its products.
The above warranty is in lieu of other warranties, either expressed or implied. No agent of ours is authorized to provide any warranty other than the above.

2

I. Introduction
This manual covers all facets of operation of the Advantage Controls Bypass Feeder, including, installation, plumbing connections, optional features and start-up. Safety, maintenance, repair, warranty and factory information are also provided. Please read this manual completely before proceeding. Observe safety protocols and heed all warnings and precautions.

Model Numbering Your Advantage Bypass Feeder may be supplied with one or more of the options described in this manual. To determine what features apply to your feeder, check the model number label located on the feeder.

Model Number (Example: BF-05DX)

BF- ____ ___ ___

Capacity 02 = 05 = 12 =
Bottom D = F =

2 gallon 5 gallon 12 gallon
Dome with legs and bottom port Flat

Filter
X = No filter 1 = 10" cartridge filter holder (20 micron hot filter included) 2 = 18" bag filter basket (25 micron bag included) 3 = 18" bag filter basket (5 micron bag included) 4 = 18" bag filter basket with no handle or filter

8 D

7

6

5

Accessory Kits

BFK-ISOVALVES = 3/4" brass isolation valves with unions and nipples C
BFK-DBDRAIN = 3/4" brass drain valve and fittings for dome bottom

BFK-FBDRAIN = 3/4" brass drain valve and fittings for flat bottom

BFK-GAUGEX

= 3/4" cross with 0-300 psi gauge, sample valve 180°F and fittings

BFK-FUNASM

= 3/4" tee isolation valve and funnel

B

Parts

BF-BAG0118

= 18" x 3" bag filter, 01 micron, 325°F

BF-BAG0518 BF-BAG2518 BF-BAG5018

= 18" x 3" bag filter, 05 micron, 325°F = 18" x 3" bag filter, 25 micron, 325°F = 18" x 3" bag filter, 50 micron, 325°F

ACME Cap DETAIL A SCALE 1 : 2 A

BF-BGCAGE18 = Bypass feeder SS bag filter cage, 18"

BF-BGCAGE18-F = Bypass feeder SS bag filter cage, no handle

8

7

6

5

BF-CF05-10

= 10" cold water cartridge filter, 05 micron, 120°F

BF-CF20-10

= 10" cold water filter, 20 micron, 120°F

BF-HF05-10

= 10" hot water cartridge filter, SS core, 05 micron, 200°F

BF-HF20-10

= 10" hot water filter, SS core, 20 micron, 200°F

BF-CFCAGE10 = Bypass feeder SS cartridge filter holder, 10"

BF-CAP BF-FUNNEL

= Bypass feeder cap assembly = Poly funnel with 3/4" MNPT

BFK-FUNASM

BF-LEGS

= Bypass feeder leg kit

BF-ORING

= Bypass feeder cap O-ring

BF-PG

= 0-300 psi pressure gauge

BF-PLATE

= Bypass feeder cap plate

FLOW-2HT

= 3/4" flow indicator; 145 psi, 212°F max

SFS-BV

= 1/4" brass bleed valve, 180°F max

BFK-ISOVALVES

3

II. Safety Considerations
A. Operation Do not install or operate the bypass feeder without reading the manual and safety protocols and warnings included. Bypass feeders are designed to operate under pressure not to exceed 200 PSI. Do not perform any maintenance or repair without first isolating the feeder from the plumbing, releasing water pressure and draining the fluid from feeder.
B. Safety and Preparation Always wear the proper protective clothing and gear when working around chemicals and chemical metering pumps. Safety glasses, gloves, and aprons are critical in preventing accidental exposure to dangerous chemicals. Liquids under pressure can present a special hazard when a line or seal is punctured resulting in the spraying of chemical many yards away. If a chemical spill occurs, consult the Material Safety Data Sheet (MSDS) for specific instructions regarding the chemical being used.
III. Installation
Several factors must be considered when installing your by-pass feeder:
A. Flow and Pressure Differential A bypass feeder requires a proper flow rate and pressure differential. The best way to achieve this to plumb the bypass line across the recirculation pump, or to install a throttling valve in the main line. A flow control valve is recommended to control and maintain the correct flow rate.
B. Flowrate Advantage Control's bypass feeders are designed for a maximum flowrate of 2 GPM for 2 gallon feeders and 5 GPM for 5 and 12 gallon feeders.
C. Pressure Differential The pressure differential should not exceed 10 PSI on non-filter filter feeder models. Feeders with either filter option should not exceed a 5 PSI differential.
D. Temperature All bypass feeders are rated to a maximum temperature of 200°F.
E. Pressure All bypass feeders are rated to a maximum pressure of 200 PSI.

Bypass Feeder Foot Print Dimensions:
A
D C

2 Gal 5 Gal 12 Gal

Mounting Foot Print

A

B

C

D

120° 7.0" (17.78cm) 8.09" (20.55cm) 6.0" (15.24cm)

120° 10.47" (26.59cm) 12.09" (30.71cm) 10.0" (25.4cm)

120° 10.47" (26.59cm) 12.09" (30.71cm) 10.0" (25.4cm)

B

4

Typical Installations: Bypass feeder with no filter or the pleated filter option.
Outlet

Outlet

Flow Restrictor
Inlet
Drain Bypass Feeder with filter bag option.
Inlet

Inlet Drain Inlet

Flow Restrictor
Outlet
Drain
IV. Optional Kits and Parts

Outlet Drain
BFK-GAUGEX BFK-ISOVALVES

BFK-FBDRAIN

BFK-DBDRAIN
5

BFK-ISOVALVES

V. Maintenance
The Advantage bypass feeder is designed for long service life and minimum maintenance. If, for any reason, maintenance is necessary or desirable, the bypass feeder is easily maintained.
A. Replacement Parts
Item No.....Description............................................................................... Part No. 1.................Bypass Feeder Cap Assembly ............................................................ BF-CAP 2.................Bypass Feeder Cap Plate ................................................................... BF-PLATE 3.................Bypass Feeder Cap O-Ring ................................................................ BF-ORING 4.................Bypass Feeder Leg Kit ........................................................................ BF-LEGS 5.................Bypass Feeder SS Bag Filter cage, 18" .............................................. BF-BGCAGE18 6.................Bypass Feeder SS Cartridge Filter Cage, 10"..................................... BF-CAGE10 7.................0-300 PSI Pressure Gauge ................................................................. BF-PG 8.................3/4" Brass Ball Valve Kit ........................................................................ BFK-ISOVALVES 9.................1/4" Brass Bleed Valve, 180°F max....................................................... SFS-BV 10................3/4" Flow Indicator; 145 PSI, 212°F max (0-10 GPM)........................... FLOW-2HT 11 ...............3/4" Brass Ball Valve ............................................................................. GV-3/4 12................Dome Bottom Drain Valve Kit.............................................................. BFK-DBDRAIN 12A. ............Flat Bottom Drain Valve Kit ................................................................. BFK-FBDRAIN 13 ...............Pressure gauge and air bleed valve with cross................................... BFK-GAUGEX 14................3/4" tee, isolation valve and funnel kit ................................................... BFK-FUNASM

BF-BGCAGE24

Bypass Feeder SS Bag Filter cage, 24"

BF-CAGE10

Bypass Feeder SS Cartridge Filter Cage, 10"

BF-PG

0-100 PSI Pressure Gauge

BF-VKIT

3/4" Brass Ball Valve Kit

14

SFS-BV

1/4" Brass Bleed Valve, 180 F max

7

FLOW-2HT

3/4" FLow Indicator; 145 PSI, 212 F max (0-10 gpm)

GV-3/4

3/4" Brass Ball Valve

BF-DBDRAINKIT

Dome Bottom Drain Valve Kit

BF-FBDRAINKIT

Flat Bottom Drain Valve Kit

3/4C

3/4" FNPT Black Iron Cross

3.375" 2.9"

11

9

13

8 10

1 2 3
12A

5

18.0"

6 11

4 12

ADVANTAGE CONTROLS, LLC PROPRIETARY
THE INFORMATION CONTAINED IN THIS DRAWING IS

PROJECT: UNLESS OTHERWISE SPECIFIED: DRAWN DIMENSIONS ARE IN INCHES CHECKED

TITLE:

INITALS DATE

HRS

SIZE DWG. NO.

B

6

VI. Troubleshooting Guide

SYMPTOM Leaking at cap
Leaking at fittings

CAUSE Improper seating of o-ring

ACTION
Remove cap, clean surface and reseat cap and closure. If problem persists, replace o-ring.

Improper seal or threading of fittings

Remove fitting and sealant and inspect threads for damage. If there is no damage,
apply sealant (thread tape or pipe dope) and reseat fitting. Replace fitting if the problem persists.

Filter damage

High particle content or excess flow rate

Check flow rate and valves. Inspect chamber for solids. Adjust valves and
replace filter. Large particle content is often a typical problem during start up.

Interior corrosion

Trapped air or chemical content

Evidence of corrosion near the inside of vessel fill port is an indication of excessive trapped air. To remove trapped air, close isolation valves and fill feeder to the brim and reinstall closure. This should be done by trained personnel. Check with chemical supplier for compatibility if corrosion is covering body interior. Do not use feeder if there is excessive corrosion.

Leaking feeder body

Unidentified pinhole during manufacture or excessive use

Occasionally, trapped gas during manufacturing may cause pin leaks to occur upon installation. Vessels that begin to leak after some time of service may be exhibiting normal wear. Typically there is no way to repair a vessel that exhibits wear, and replacement may be necessary. Consult the factory for recommendation.

7

Get the Advantage in Water Treatment Equipment
Advantage Controls can give you the Advantage in products, knowledge and support on all of your water treatment equipment needs.
· Cooling Tower Controllers

· Boiler Blow Down Controllers

· Blow Down Valve Packages

· Solenoid Valves

· Water Meters

· Chemical Metering Pumps

· Corrosion Coupon Racks

· Chemical Solution Tanks

· Solid Feed Systems

· Feed Timers

· Filter Equipment

· Glycol Feed Systems · Pre-Fabricated Systems

160 spm

External Pulse

Auto Stopped

MENU ENTER

ENTER
Get the Advantage 8



References

Adobe PDF Library 17.0 Adobe InDesign 19.5 (Windows)