Installation Guide for tekmar models including: 519, Radiant Thermostat, 519 Radiant Thermostat

Installation & Operation Manual - Watts

If the sensor is to be installed to the bottom of a subfloor, cut a piece of 1” (25 mm) thick rigid insulation into a 6” (150 mm) by 6” (150 mm) square. A groove 3/16” (5 mm) wide by 3/16” ( ...

Jan 26, 2021 — The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating zone using Pulse Width Modulation (PWM) technology.

Installation & Operation Manual © 20t

© 2020 tekmar 519 D - 12/20 6 of 16 Tile Floor Coverings If a Slab Sensor 079 is to be installed into an existing tile floor with sufficiently large


File Info : application/pdf, 16 Pages, 1.33MB

PDF preview unavailable. Download the PDF instead.

519 dl 03
Installation & Operation Manual
Radiant Thermostat 519

Zoning

519_D
12/20
Replaces: 06/16

Introduction
The Radiant Thermostat 519 accurately controls the room and/or floor temperature for a hydronic heating zone using Pulse Width Modulation (PWM) technology. Simple up and down buttons and a display with large type make this thermostat easy to read and use. A Slab Sensor 079 is included to measure floor temperature to protect the floor from overheating and enhance comfort. This easy to install thermostat is a direct replacement for the tekmar Thermostat 509.

Energy Saving Features
· Away Input · Auto Heating Cycle
Additional Features
· Radiant Floor Heating · Pulse Width Modulation · Floor & Air Temperature Control · Outdoor & Floor Temperature
Display · Backlight · Freeze Protection · Includes Slab Sensor 079

© 2020 tekmar 519_D - 12/20

Table of Contents

Installation ...........................................3 Preparation .....................................3 Removing The Thermostat Base ....3 Mounting The Thermostat...............4 Slab Sensor 079 Installation ...........5 Slab Sensor 079 Wiring ..................6 Slab Sensor 079 Testing .................7 Temperature vs. Resistance Table ....7 Thermostat Wiring ..........................9 Testing the Thermostat Wiring......10

User Interface .................................... 11 Home Screen ................................ 11 Symbols Description ..................... 11
Sequence of Operation......................12 Heating Operation.........................12
Programmable Settings .....................13
Troubleshooting ................................. 14 Error Messages ............................14 Frequently Asked Questions.........15
Technical Data...................................15
Limited Warranty ...............................16

Important Safety Information
This is a safety-alert symbol. The safety alert symbol is shown alone or used with a signal word (DANGER, WARNING, or CAUTION), a pictorial and/or a safety message to identify hazards. When you see this symbol alone or with a signal word on your equipment or in this Manual, be alert to the potential for death or serious personal injury.
This pictorial alerts you to electricity, electrocution, and shock hazards.

This symbol identifies hazards which, if not avoided, could result in death or serious injury.
This symbol identifies hazards which, if not avoided, could result in minor or moderate injury.
This symbol identifies practices, actions, or failure to act which could result in property damage or damage to the equipment.

Read Manual and all product labels BEFORE using the equipment. Do not use unless you know the safe and proper operation of this equipment. Keep this Manual available for easy access by all users. Replacement Manuals are available at tekmarControls.com

Do not attempt to service the thermostat. There are no user serviceable parts inside the thermostat. Attempting to do so voids warranty.

© 2020 tekmar 519_D - 12/20

2 of 16

· It is the installer's responsibility to ensure that this thermostat is safely installed according to all applicable codes and standards.
· Improper installation and operation of this thermostat could result in damage to the equipment and possibly even personal injury or death.
· This thermostat is not intended for use as a primary limit control. Other controls that are intended and certified as safety limits must be placed into the control circuit.

Installation

Preparation

Tools Required ------------------------------------------------------

· tekmar or jeweller screwdriver

· Wire Stripper

· Phillips head screwdriver

Materials Required -------------------------------------------------· 18 AWG LVT Solid Wire (Low Voltage Connections)
Installation Location ------------------------------------------------Choose the placement of the thermostats early in the construction process to enable proper wiring during rough-in.

Consider the following: · Interior Wall. · Keep dry. Avoid potential leakage onto the control. · Relative Humidity less than 90%. Non-condensing environment. · No exposure to extreme temperatures beyond 32-122°F (0-50°C). · No draft, direct sun, or other cause for inaccurate temperature readings. · Away from equipment, appliances, or other sources of electrical
interference. · Easy access for wiring, viewing, and adjusting the display screen. · Approximately 5 feet (1.5 m) off the finished floor. · The maximum length of wire is 500 feet (150 m). · Strip wire to 3/8" (10 mm) for all terminal connections. · Use standard 8 conductor, 18 AWG wire.

Removing The Thermostat Base
To remove the thermostat base: · Locate the tab on the bottom of the
thermostat. · Push the tab with either your thumb or with
a screwdriver. · Lift the thermostat front away from the
thermostat's base.
3 of 16

© 2020 tekmar 519_D - 12/20

Mounting The Thermostat

To prevent the risk of personal injury and/or death, make sure power is not applied to the thermostat until it is fully installed and ready for final testing. All work must be done with power to the circuit being worked on turned off.
Please be aware local codes may require this thermostat to be installed or connected by an electrician.

Thermostat Front

Adapter Plate 012
Thermostat Base

Stud
3 1/4" (83 mm)

Gang Box

If a single gang box is used: · Adapter Plate 012 is required (sold separately). · Feed the wiring through the hole in the adapter plate and the thermostat base. · Fasten the adapter plate to the gang box. · Fasten the base of the thermostat to the adapter plate. · Terminate wiring to the wiring strip. Do not over tighten wiring screws. Hand
tighten only. · Push the thermostat front onto the thermostat base.

Thermostat Front

Thermostat Base

Wall

If mounting directly to the wall: · Drill holes using a 3/16" drill bit and install the wall anchors. · Feed the wiring through the large hole in the thermostat base. · Fasten the thermostat base to the wall using the wood screws to the wall anchors. · Terminate wiring to the wiring strip. Do not over tighten wiring screws. Hand
tighten only. · Push the thermostat front onto the thermostat base.

© 2020 tekmar 519_D - 12/20

4 of 16

Slab Sensor 079 Installation

New Installations ----------------------------------------------------

Thin-Set or Thin-Pour Applications

If the floor covering is to be installed over either a thin-set or thin-pour material of sufficient

depth, the 079 slab sensor can be placed directly into either the thin-set material or the

thin-pour material and covered over. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location. Splices within the thin-set or thin-pour should be avoided to ensure trouble

Tiles Thin-set
Electric Cables

free operation. The sensor should be located

mid way between the heating elements to ensure

a proper temperature reading.

Thin Floor Coverings (less than 3/8" (10 mm))
If a thin floor covering is to be installed directly to the subfloor, a groove 1/8" (4 mm) wide by 1/16" (2 mm) deep can be cut into the surface of the subfloor to accommodate the wire for the sensor. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction Hardwood location. Splices under the floor covering should be avoided to ensure trouble free operation. Subfloor A groove 3/16" (5 mm) wide by 3/16" (5 mm) deep by 1-3/4" (45 mm) long should be cut to accommodate the sensor. The sensor should be located mid way between the heating elements to
ensure a proper temperature reading.

Thick Floor Coverings (greater than 3/8" (10 mm))

If a thick floor covering is to be installed directly to the subfloor, a groove 1/8" (4 mm) wide by 1/16" (2 mm) deep can be cut into the back of the flooring material to accommodate the wire for the sensor. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location.

Splices under the floor covering should be avoided
to ensure trouble free operation. A groove 3/16" (5 mm) wide by 3/16" (5 mm) deep by 1-3/4" (45 mm) long should be cut to accommodate the sensor. The sensor should be located mid way between the heating elements to ensure a proper
temperature reading.

Hardwood Subfloor

NOTE: If it is not practical to cut a groove in the surface covering, follow the installation method used for thin floor coverings.

5 of 16

© 2020 tekmar 519_D - 12/20

Retrofit Installations -------------------------------------------------

Tile Floor Coverings

If a Slab Sensor 079 is to be installed into an existing tile floor with sufficiently large

grout lines, the sensor and wire can be installed in one of the grout lines between the

tiles. Select a low traffic area of the floor that is mid way between the heating elements

for the sensor location. Ensure that the sensor is located in such a position that the attached wire is able to reach to a suitable junction location. Splices within the grout should be avoided to ensure

Tiles Thin-set
Subfloor

trouble free operation. Remove the appropriate

grout line and place the sensor and wire in the

floor. Re-grout the area.

Installing the Sensor to the Bottom of a Subfloor

If the sensor is to be installed to the bottom of a subfloor, cut a piece of 1" (25 mm) thick

rigid insulation into a 6" (150 mm) by 6" (150 mm) square. A groove 3/16" (5 mm) wide by 3/16" (5

Subfloor

mm) deep by 1-3/4" (45 mm) long should be cut

into the insulation to accommodate the sensor.

Place the sensor in the groove and sandwich the

sensor between the insulation and the subfloor. Use

a suitable fastening method to affix the insulation to

the subfloor.

Slab Sensor 079 Wiring
Caution: Do not run sensor wires parallel to telephone or power cables. If the sensor wires are located in an area with strong sources of electromagnetic interference, shielded cable or twisted pair should be used or the wires can be run in a grounded metal conduit.
The Slab Sensor 079 is supplied with 10' (3 m) of cable. If a longer length is required, 24 AWG or larger wire can be spliced onto the two wires from the sensor. The splices should be properly soldered and protected in an accessible junction box. Follow the sensor testing instructions given in this brochure and then connect the wires to the control.

© 2020 tekmar 519_D - 12/20

6 of 16

Slab Sensor 079 Testing
A good quality test meter capable of measuring up to 5,000 k (1 k = 1000) is required to measure the sensor resistance. In addition to this, the actual temperature must be measured with either a good quality digital thermometer, or if a thermometer is not available, a second sensor can be placed alongside the one to be tested and the readings compared.
First measure the room temperature using the thermometer. Disconnect the Sen and Com wires from the thermostat. Using an electrical meter, measure the resistance of the Sen and Com wires at the thermostat location. Using the temperature versus resistance table, estimate the temperature measured by the sensor. The sensor measurement and thermometer readings should be close. If the test meter reads a very high resistance, there may be a broken wire, a poor wiring connection or a defective sensor. If the resistance is very low, the wiring may be shorted, there may be moisture in the sensor or the sensor may be defective. To test for a defective sensor, measure the resistance directly at the sensor location. Once the test has been completed, reconnect the Sen and Com wires to the thermostat.
Do not apply voltage to the temperature sensor terminals at any time as damage to the sensor may result.

Temperature vs. Resistance Table

Temperature

°F

°C

-50

-46

-45

-43

-40

-40

-35

-37

-30

-34

-25

-32

-20

-29

-15

-26

-10

-23

-5

-21

0

-18

5

-15

10

-12

15

-9

20

-7

Resistance
490,813 405,710 336,606 280,279 234,196 196,358 165,180 139,402 118,018 100,221 85,362 72,918 62,465 53,658 46,218

Temperature

°F

°C

25

-4

30

-1

35

2

40

4

45

7

50

10

55

13

60

16

65

18

70

21

75

24

80

27

85

29

90

32

95

35

Resistance
39,913 34,558 29,996 26,099 22,763 19,900 17,436 15,311 13,474 11,883 10,501 9,299 8,250 7,334 6,532

7 of 16

© 2020 tekmar 519_D - 12/20

Temperature vs. Resistance Table - Continued

Temperature

°F

°C

100

38

105

41

110

43

115

46

120

49

125

52

130

54

135

57

140

60

145

63

150

66

155

68

160

71

Resistance
5,828 5,210 4,665 4,184 3,760 3,383 3,050 2,754 2,490 2,255 2,045 1,857 1,689

Temperature

°F

°C

165

74

170

77

175

79

180

82

185

85

190

88

195

91

200

93

205

96

210

99

215

102

220

104

225

107

Resistance
1,538 1,403 1,281 1,172 1,073 983 903 829 763 703 648 598 553

© 2020 tekmar 519_D - 12/20

8 of 16

Thermostat Wiring Zone Valve ----------------------------------------------------------

Zone Valve
RC
24 V (ac) Transformer
009 LN

Install field jumper wire R to Rh

NoNPooPwoewr er

5189

C R Rh W1 S1 Com Away

Slab Sensor 079
Do not over tighten wiring screws. Hand tighten only.

Wiring Center 315 or 316 ---------------------------------------------

Install field jumper wire R to Rh

Slab Sensor 079

tN4 C R W
Wiring Center 315 or 316

NoNPooPwoewr er

5189

C R Rh W1 S1 Com Away

Do not over tighten wiring screws. Hand tighten only.

Relay 003 -----------------------------------------------------------

Relay 003

3

2

4

1

5

8

6

7

Install field jumper wire R to Rh

Slab Sensor 079

RC

NoNPooPwoewr er

5189

C R Rh W1 S1 Com Away

NL G Transformer

115 V (ac)

009

9 of 16

Do not over tighten wiring screws. Hand tighten only.
© 2020 tekmar 519_D - 12/20

Thermostat Wiring Switching Relay -----------------------------------------------------

RWRW RW Zone 1 Zone 2 Zone 3

24 V

Com

Switching Relay

Class 2

XX

Transformer

Zone 1 Zone 2 Zone 3 HNHNHN

NH

NL Pump

NoNPooPwoewr er

5189

C R Rh W1 S1 Com Away

Slab Sensor 079
Do not over tighten wiring screws. Hand tighten only.

Testing the Thermostat Wiring
Testing the Power ---------------------------------------------------
If the thermostat display turns on, this indicates that the thermostat is operating correctly and there are no electrical issues. In the event that the display is permanently off:
1. Remove the thermostat front.
2. Use an electrical meter to measure voltage between the R and C wiring terminals. For AC power supplies the voltage should measure between 10 to 30 V (ac). For DC power supplies the voltage should measure between 10 to 30 V (dc).
3. If the voltage on the R and C wire terminations is continuous and the thermostat display is not on, the thermostat may have a fault. Contact your tekmar sales representative for assistance.
If the thermostat display initially powers on but later shuts off intermittently, there may be a short circuit from the W wire to ground, or the power supply is too small to power the load.
Testing the Heat Zone Output Wiring----------------------------------
1. Touch the button and set the heating temperature above the current room temperature. Make sure the display does not flash "Max" if using a floor sensor.
2. When the "Heat On" symbol appears on the display, use an electrical meter to check for voltage on the W and C wires connected to the zone valve, wiring center, relay or switching relay. The electrical meter should read 10 to 30 V (ac) or (dc).
3. If the W and C wire have voltage, check the zone valve, wiring center, relay or pump to determine if the heat device is operating correctly.

© 2020 tekmar 519_D - 12/20

10 of 16

User Interface
Home Screen
Away

Symbols Description
HEAT ON Heat is turned on.
MODE OFF The heating system is off.
WARNING SYMBOL Indicates an error is present.

MIN The floor is at or below the floor minimum temperature.
MAX The floor has reached the floor maximum temperature.
AWAY Operating at the away temperature.

11 of 16

© 2020 tekmar 519_D - 12/20

Sequence of Operation
Heating Operation
Push the or button to select a preferred temperature setting. The Heat On symbol is shown on the display when the thermostat is heating. The heat can cycle on and off within +/- 1.5°F (1°C) of the temperature setting.
The floor and air heating can be shut off by holding the button until Set Room is Off.
To resume heating when the Mode is Off, press the button to navigate to the Mode setting, then press the button to select Mode Heat. The thermostat will resume heating at the last previously set temperature.
The away feature saves energy by heating to a lower temperature while you are away. To activate Away, short the Away and Com wiring terminals together.
Air Temperature Only ------------------------------------------------
If there is only an air temperature sensor (no floor sensor), the thermostat operates to control your desired air temperature.
Floor Temperature Only ----------------------------------------------
If the air sensor has been disabled, the thermostat will only maintain floor temperature and ignore air temperature. This operation is recommended for areas such as bathrooms to ensure that tile floors are warm to the touch.
Floor and Air Temperature -------------------------------------------
If the air sensor is turned on and a floor sensor is connected, the thermostat will maintain the desired air temperature as well as a minimum floor temperature.
This operation is recommended for areas with large windows that allow the sun to shine into a room and keep it warm without the need for heat. This can allow the floors to cool off during the afternoon. When the sun goes down, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room.
This operation is also recommended for rooms with hardwood floors. Setting floor minimum and maximum temperatures is a way of enhancing the comfort of the living space while protecting floor coverings.

90°F (32°C) Feels hot to the touch
80 to 85°F (26 to 30°C) Feels warm to the touch
70°F (21°C) Feels cool to the touch

Suggested maximum for all floor types other than wood.
Bathrooms and kitchens. Suggested maximum for wood floors.
Rooms with large windows preventing under heating in the evening.

40 to 45°F (5 to 7°C) Feels cold to the touch
© 2020 tekmar 519_D - 12/20

Freeze protection for garages.
12 of 16

Programmable Settings

Setting

Display

User settings. Press the and buttons together for 3 seconds to enter and advance to the next setting.

MODE Select heat or off.

Range: HEAT, OFF

Default: HEAT

UNITS Select the temperature units.

Range: °F or °C

Default: °F

LIGHT Select when the display back light should operate. Auto operates the backlight for 30 seconds after a keystroke.

Range: OFF, AUTO, ON

Default: AUTO

SET FLOOR Set the floor minimum temperature. Available

when an auxiliary floor sensor is connected and the built-in

F

room sensor is on.

Range: OFF, 40 to 122°F (4.5 to 50.0°C)

Default: 72°F (22.0°C)

TYPE Device Type number. Hold the button to view the software version.

ESCAPE Release the and buttons to return to the home screen.

Installer settings. Press the and buttons together for 5 more seconds.

AUXILIARY SENSOR Select the type of auxiliary sensor. Available when an auxiliary sensor is automatically detected.

Range: NONE = no auxiliary sensor, ROOM = Indoor Sensor, FLOR = Slab Sensor, OUT = Outdoor Sensor

Default: OFF

ROOM SENSOR Select if the built-in room temperature

sensor is on or off. The built-in room sensor can only be

disabled when an auxiliary room or slab sensor is connected.

Room

Range: ON or OFF

Default: ON

SET FLOOR MAXIMUM Set the floor maximum temperature

in order to protect the floor covering. Suggested settings:

MAX

F

Tile = 90°F (32°C), Wood Floor = 85°F (29°C)

Range: 40 to 122°F (4.5 to 50.0°C), OFF

Default: 85°F (29.5°C)

SET AWAY Set the away temperature.

F

Range: OFF, 40 to 122°F (4.5 to 35.0°C)

Default: 50°F (10.0°C)

ESCAPE Release the and buttons to return to the home screen.

13 of 16

© 2020 tekmar 519_D - 12/20

Troubleshooting
Error Messages
Error Message Description
SETUP MENU SAVE ERROR The thermostat failed to read the Programmable Settings from memory and has reloaded the factory default settings. The thermostat stops normal operation until all Programmable Settings are checked except to provide freeze protection.

ROOM SENSOR OPEN CIRCUIT ERROR
The built-in air temperature sensor has an open circuit fault. Do not confuse this error with the auxiliary room sensor short circuit error.

Room

This error cannot be field repaired. Contact your wholesaler or tekmar

sales representative for details on repair procedures.

ROOM SENSOR SHORT CIRCUIT ERROR

The built-in air temperature sensor has a short circuit fault. Do not confuse this error with the auxiliary room sensor short circuit error.

Room

This error cannot be field repaired. Contact your wholesaler or tekmar

sales representative for details on repair procedures.

AUXILIARY SENSOR OPEN CIRCUIT ERROR
The auxiliary sensor has an open circuit. Check for loose or damaged wires. Locate and repair the problem as described in the Sensor Testing section of this brochure. The error clears after the auxiliary sensor fault is corrected. If the auxiliary sensor was intentionally removed, power the thermostat down and up to clear the error.

AUXILIARY SENSOR SHORT CIRCUIT ERROR
The auxiliary sensor has a short circuit. Check for damaged wires. Locate and repair the problem as described in the Sensor Testing section of this brochure. The error clears after the auxiliary sensor fault is corrected.

© 2020 tekmar 519_D - 12/20

14 of 16

Frequently Asked Questions

Symptom

Look for...

Display powering on and off.

Measure voltage at wiring terminals R
and C.

Corrective Action
The power supply transformer may have limited VA capacity. A transformer with a larger VA rating is
recommended.

Thermostat does not heat.

Mode Off

Thermostat must be in Mode Heat in order to provide heating.

Technical Data

Radiant Thermostat 519 One Stage Heat

Literature

519_C, 519_D, 519_Q, 519_U

Control

Microprocessor control. This is not a safety (limit) control

Packaged weight 0.6 lb. (290 g)

Dimensions

3-11/16" H x 3" W x 15/16" D (94 x 76 x 24 mm)

Enclosure

White PVC plastic, NEMA Type 1

Approvals

Meets Class B: ICES & FCC Part 15

Ambient conditions Indoor use only, 32 to 122°F (0 to 50°C), RH 90% non-condensing

Power supply

10 to 30 V (ac/dc), 50/60 Hz, 1.8 VA standby, 56 VA max fully loaded, Class 2

Relay

30 V (ac/dc) 2 A, Class 2 circuits

Sensor

NTC thermistor, 10 k @ 77°F (25°C ±0.2°C) ß=3892

­ Included

Slab Sensor 079

­ Optional

tekmar type # 070, 072, 073, 076, 077, 079, 084

Slab Sensor 079 10' (3 m) wire

Dimensions

3/16" OD x 1-1/2" (5 OD x 38 mm)

Enclosure

316 stainless steel, 10' (3 m) 24 AWG, 300 volt PVC insulated Zipcord

Operating range -58 to 140°F (-50 to 60°C)

Sensor

NTC thermistor, 10 k @ 77°F (25°C ±0.2°C) ß=3892

15 of 16

© 2020 tekmar 519_D - 12/20

Limited Warranty and Product Return Procedure
Limited Warranty The liability of tekmar under this warranty is limited. The Purchaser, by taking receipt of any tekmar product ("Product"), acknowledges the terms of the Limited Warranty in effect at the time of such Product sale and acknowledges that it has read and understands same.
The tekmar Limited Warranty to the Purchaser on the Products sold hereunder is a manufacturer's passthrough warranty which the Purchaser is authorized to pass through to its customers. Under the Limited Warranty, each tekmar Product is warranted against defects in workmanship and materials if the Product is installed and used in compliance with tekmar's instructions, ordinary wear and tear excepted. The passthrough warranty period is for a period of twenty-four (24) months from the production date if the Product is not installed during that period, or twelve (12) months from the documented date of installation if installed within twenty-four (24) months from the production date.
The liability of tekmar under the Limited Warranty shall be limited to, at tekmar's sole discretion: the cost of parts and labor provided by tekmar to repair defects in materials and / or workmanship of the defective product; or to the exchange of the defective product for a warranty replacement product; or to the granting of credit limited to the original cost of the defective product, and such repair, exchange or credit shall be the sole remedy available from tekmar, and, without limiting the foregoing in any way, tekmar is not responsible, in contract, tort or strict product liability, for any other losses, costs, expenses, inconveniences, or damages, whether direct, indirect, special, secondary, incidental or consequential, arising from ownership or use of the product, or from defects in workmanship or materials, including any liability for fundamental breach of contract.
The pass-through Limited Warranty applies only to those defective Products returned to tekmar during the warranty period. This Limited Warranty does not cover the cost of the parts or labor to remove or transport the defective Product, or to reinstall the repaired or replacement Product, all such costs and expenses being subject to Purchaser's agreement and warranty with its customers.
Any representations or warranties about the Products made by Purchaser to its customers which are different from or in excess of the tekmar Limited Warranty are the Purchaser's sole responsibility and obligation. Purchaser shall indemnify and hold tekmar harmless from and against any and all claims, liabilities and damages of any kind or nature which arise out of or are related to any such representations or warranties by Purchaser to its customers.
The pass-through Limited Warranty does not apply if the returned Product has been damaged by negligence by persons other than tekmar, accident, fire, Act of God, abuse or misuse; or has been damaged by modifications, alterations or attachments made subsequent to purchase which have not been authorized by tekmar; or if the Product was not installed in compliance with tekmar's instructions and / or the local codes and ordinances; or if due to defective installation of the Product; or if the Product was not used in compliance with tekmar's instructions.
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, WHICH THE GOVERNING LAW ALLOWS PARTIES TO CONTRACTUALLY EXCLUDE, INCLUDING, WITHOUT LIMITATION, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, DURABILITY OR DESCRIPTION OF THE PRODUCT, ITS NON-INFRINGEMENT OF ANY RELEVANT PATENTS OR TRADEMARKS, AND ITS COMPLIANCE WITH OR NON-VIOLATION OF ANY APPLICABLE ENVIRONMENTAL, HEALTH OR SAFETY LEGISLATION; THE TERM OF ANY OTHER WARRANTY NOT HEREBY CONTRACTUALLY EXCLUDED IS LIMITED SUCH THAT IT SHALL NOT EXTEND BEYOND TWENTY-FOUR (24) MONTHS FROM THE PRODUCTION DATE, TO THE EXTENT THAT SUCH LIMITATION IS ALLOWED BY THE GOVERNING LAW.
Product Warranty Return Procedure All Products that are believed to have defects in workmanship or materials must be returned, together with a written description of the defect, to the tekmar Representative assigned to the territory in which such Product is located. If tekmar receives an inquiry from someone other than a tekmar Representative, including an inquiry from Purchaser (if not a tekmar Representative) or Purchaser's customers, regarding a potential warranty claim, tekmar's sole obligation shall be to provide the address and other contact information regarding the appropriate Representative.
WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. For more information: Watts.com/prop65

519_D - 12/20

All specifications are subject to change without notice

Tel: (250) 545-7749 · Fax: (250) 984-0815 tekmarControls.com

16 of 16

© 2020 tekmar

