Glucoracy G-425-2

Manual del usuario del kit de monitor de glucosa en sangre Glucoracy G-425-2

Modelo: G-425-2

Introducción

This manual provides detailed instructions for the safe and effective use of your Glucoracy G-425-2 Blood Glucose Monitor Kit. Please read all instructions carefully before use to ensure accurate results and proper operation. This kit is designed for self-testing blood glucose levels at home.

Contenido del kit

Your Glucoracy G-425-2 Blood Glucose Monitor Kit includes the following components:

  • 1 x Glucoracy G-425-2 Blood Glucose Meter
  • 1 dispositivo de punción.
  • 100 tiras de prueba
  • 100 lancetas
  • 1 x bolsa de viaje
  • Manuales de usuario
Glucoracy G-425-2 Blood Glucose Monitor Kit contents including glucometer, lancing device, test strips, and lancets.

Image: Complete Glucoracy G-425-2 Blood Glucose Monitor Kit components.

Configuración

1. Instale las baterías

The Glucoracy G-425-2 meter requires 2 AAA batteries (not included). Open the battery compartment on the back of the meter and insert the batteries, ensuring correct polarity. Close the compartment securely.

2. Assemble Lancing Device

  1. Unscrew the cap from the lancing device.
  2. Inserte firmemente una lanceta nueva y estéril en el porta lancetas.
  3. Retire la tapa protectora de la lanceta.
  4. Vuelva a colocar la tapa del dispositivo de punción.
  5. Adjust the penetration depth by rotating the cap. Levels 1-2 are for tender skin, 3 for general, and 4-5 for thick skin.
  6. Pull back the cocking control until it clicks, indicating the device is ready.
Image showing the lancing device with adjustable depth settings from 1 to 5, indicating suitability for different skin types.

Image: Lancing device with adjustable depth settings.

Instrucciones de funcionamiento

Before Testing: Important Reminders

  • Ensure your testing site is clean and free of alcohol, dirt, or other substances. Wash and dry your hands thoroughly.
  • Use a sufficient blood sample. Avoid the first drop of blood; wipe it away and use the second drop.
  • Check that test strips are within 3 months of opening and stored properly in their sealed container, away from heat and moisture.
  • Be mindful of high humidity, which can affect results.
  • The fingertip is the recommended testing site for most accurate results.
Infographic showing factors affecting blood glucose test accuracy and their solutions, such as clean skin, sufficient blood, proper strip storage, and using fingertip.

Image: Factors affecting test accuracy and solutions.

Cómo realizar una prueba de glucosa en sangre

  1. Prepare Hands: Wash your hands with soap and warm water, then dry them completely.
  2. Inserte la tira de prueba: Remove a test strip from its vial and immediately close the vial lid. Insert the test strip into the meter. The meter will turn on automatically.
  3. Obtener sangre Sampen: Place the assembled lancing device firmly against the side of your fingertip and press the release button. Gently squeeze your finger until a small drop of blood forms. Wipe away the first drop of blood with a clean tissue, then gently squeeze again to get a second drop.
  4. Aplicar sangre: Toque la gota de sangre con la punta de la tira reactiva. La sangre se absorberá automáticamente en la tira. No aplique sangre en la parte superior de la tira.
  5. Leer resultados: El medidor mostrará el resultado de glucosa en sangre en 5 segundos.
  6. Eject Strip and Lancet: Use the one-button push ejection feature to safely dispose of the used test strip and lancet.
Image illustrating the 8 simple steps for blood glucose testing, from washing hands to ejecting the strip and lancet.

Image: 8 Simple steps for blood glucose testing.

Memory Tracking

The Glucoracy G-425-2 glucometer can store up to 500 blood sugar results, helping you monitor your glucose status over time. To access memory mode, refer to the specific instructions in your meter's user manual. The meter also allows for testing at different times relative to meals:

  • Fasting: After >8 hours of no food intake.
  • Before Meal: 10-30 minutes before eating.
  • After Meal: 2 hours after eating.
  • Before Sleep: 30 minutos antes de ir a dormir.
Image showing the Glucoracy glucometer display with a reading of 98 mg/dL, and icons indicating different testing times like fasting, before meal, after meal, and before sleep.

Image: Glucometer display and suggested testing times.

Mantenimiento

Test Strip Storage

  • Guarde las tiras de prueba en su frasco original con la tapa bien cerrada.
  • Mantenga las tiras en un lugar fresco y seco, lejos de la luz solar directa y del calor.
  • No refrigere ni congele las tiras de prueba.
  • Use test strips within 3 months after opening the vial. Write the opening date on the vial.

Limpieza del medidor y del dispositivo de punción

Limpie el exterior del medidor y el dispositivo de punción con un paño suave y seco.amp cloth. Do not immerse the devices in water or use harsh cleaning agents.

Solución de problemas

If you encounter any issues, refer to the table below for common error messages and their solutions. If the problem persists or an unfamiliar error message appears, please contact Glucoracy customer service.

MensajeQué significaAcción
LoBlood glucose level is lower than 20 mg/dL.Consult with your healthcare professional immediately.
HiEl nivel de glucosa en sangre es superior a 600 mg/dL.Busque asistencia médica inmediata.
Control de accesoMeter is ready to test control solution.Place a drop of control solution onto the test well of the test strip.
EbLa carga de la batería es baja.Reemplace las baterías.
UESe inserta una tira de prueba usada.Utilice una tira nueva y vuelva a realizar la prueba.
ESIndicates you may have removed the strip prematurely after applying blood to the absorbent hole.Try again with a new strip, ensuring sufficient blood sample and proper application.
EEProblema con el medidor.Re-test with a new test strip. If the problem is still unresolved, please contact customer care.
etEnvironmental temperature is lower than 50°F or higher than 104°F.Test at an environmental temperature within 50°F–104°F (10°C–40°C) operation range.
Table showing various error messages like Lo, Hi, E-b, E-U, E-F, E-E, E-t, their meanings, and recommended actions for the Glucoracy blood glucose monitor.

Image: Common error messages and troubleshooting steps.

Presupuesto

  • Nombre del modelo: G-425-2
  • Dimensiones del producto: 4.13" de largo x 2.76" de ancho x 6.3" de alto
  • Peso del artículo: 8.5 onzas
  • Baterías: Se requieren 2 pilas AAA (no incluidas)
  • Composición de la celda de la batería: Alcalino
  • Capacidad de memoria: Up to 500 blood sugar results
  • Sangre SampVolumen del archivo: 0.5 µL
  • Tiempo de prueba: 5 segundos
  • Lancing Device Depth Settings: 5 niveles
  • Mostrar: Pantalla grande de 2.7"

Información importante

This device is intended for self-testing and monitoring of blood glucose levels. It is not intended for the diagnosis of diabetes. Always consult with a healthcare professional for diagnosis and treatment decisions.

Indicaciones: For individuals managing diabetes.

Atención al cliente

For any questions, concerns, or technical assistance, please contact Glucoracy customer service. Refer to the packaging or the official Glucoracy websitio para detalles de contacto.

You can also visit the official Glucoracy store for more information: Glucoracy Store

© 2023 Glucoracy. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.