YUANWIN YW-TF1LCD-P9-1200lb

YUANWIN Door Access Control System Kit

Manual de instrucciones de usuario

1. Producto terminadoview

The YUANWIN Door Access Control System Kit provides a comprehensive security solution for various environments, including offices, homes, and commercial buildings. This system offers multiple access methods, including RFID card, fingerprint recognition, and password entry, ensuring flexible and secure access management. It features a durable magnetic lock and a user-friendly controller with an LCD screen for easy operation.

2. Contenido del paquete

Verifique que todos los siguientes componentes estén incluidos en su paquete:

  • Access Control Keypad with LCD Screen
  • 1200LB Magnetic Lock
  • Controlador de fuente de alimentación
  • Infrared Wireless Exit Switch
  • Cable de alimentación
  • RFID Cards (multiple)
  • Mounting Hardware (screws, anchors, L-bracket, Z-bracket if applicable)
All components of the YUANWIN Door Access Control System Kit laid out.

Figure 2.1: Complete YUANWIN Door Access Control System Kit components.

3. Especificaciones

CaracterísticaDescripción
MarcaYUANWIN
Número de modeloYW-TF1LCD-P9-1200lb
Tipo de bloqueo1200LB Magnetic Lock
Métodos de accesoFingerprint, RFID Card, Password
Pantalla del controladorPantalla LCD
Exit MechanismInfrared Wireless Switch
Entrada de potenciaAC110V-240V (1A) 50Hz
Potencia de salida12 V CC (4 A)
Dimensiones del artículo (largo x ancho x alto)11 x 9 x 4 pulgadas
Peso del artículo11 libras

4. Configuración e instalación

Careful installation is crucial for optimal performance and security. It is recommended to consult a professional electrician if you are unfamiliar with electrical wiring.

4.1 Identificación de componentes

Close-up of the access control keypad with LCD screen and fingerprint scanner.

Figure 4.1.1: Access Control Keypad

Dimensions of the 1200LB magnetic lock and its armature plate.

Figure 4.1.2: 1200LB Magnetic Lock with dimensions

Close-up of the power supply controller with wiring terminals.

Figure 4.1.3: Power Supply Controller

Close-up of the infrared wireless exit switch with a person exiting icon.

Figure 4.1.4: Infrared Wireless Exit Switch

4.2 pasos de instalación

  1. Monte el bloqueo magnético:
    • Determine the optimal mounting location for the magnetic lock on the door frame and the armature plate on the door. Ensure proper alignment for secure locking.
    • Use the provided mounting hardware to securely attach the magnetic lock to the door frame.
    • Attach the armature plate to the door, ensuring it aligns perfectly with the magnetic lock when the door is closed.
    • Diagram showing the magnetic lock mounted on a door frame and the armature plate on the door.

      Figure 4.2.1: Magnetic Lock Installation Example

  2. Mount the Access Control Keypad:
    • Choose a convenient location on the exterior side of the door or wall for the keypad.
    • Securely mount the keypad using the provided screws.
    • Access control keypad installed on a wall next to a glass door.

      Figure 4.2.2: Keypad Mounted on Wall

  3. Mount the Infrared Wireless Exit Switch:
    • Install the exit switch on the interior side of the door or wall, within easy reach.
    • Ensure it is mounted securely.
    • Infrared wireless exit switch installed on a wall next to a glass door.

      Figure 4.2.3: Exit Switch Mounted on Wall

  4. Connect the Power Supply Controller:
    • Mount the power supply controller in a secure and accessible location, preferably near a power outlet.
    • Connect the power cable to the power supply controller.
  5. Diagrama de cableado:

    Follow the wiring diagram carefully to connect all components. Incorrect wiring can damage the system or pose a safety hazard.

    Detailed wiring diagram for the access control system, showing connections between keypad, power supply, magnetic lock, and exit switch.

    Figure 4.2.4: Wiring Diagram of the Access Control System

    This diagram illustrates the connections between the Access Control Keypad, Power Supply, Magnetic Lock, and the Infrared Wireless Exit Switch. Ensure all wires are connected to their corresponding terminals as indicated by color and function (e.g., NC, NO, +12V, GND, COM, OPEN, D0, D1, BELL, PUSH, CTRL+).

    Diagram showing the placement of the access control keypad outside the door and the magnetic lock, power supply, and exit switch inside the door.

    Figure 4.2.5: System Component Placement (Outside vs. Inside)

  6. Encendido: Once all connections are secure, plug in the power supply. The system should power on and the keypad display will activate.

5. Instrucciones de funcionamiento

This section details the basic operation of your YUANWIN Door Access Control System, including user management and unlocking methods.

5.1 Initial Setup and Admin Code

Upon first power-up, the system will be in a default state. The default admin code is 999999. It is highly recommended to change this code immediately after initial setup for security purposes.

Para ingresar al modo de programación, presione * then enter the admin code (default 999999) followed by #.

5.2 Gestión de usuarios

The system supports adding and deleting users via RFID cards, PINs, and fingerprints.

  1. Adding an RFID Card:
    • Ingrese al modo de programación.
    • Prensa 1 to enter the "Add Card" menu.
    • Present the RFID card to the keypad's card reader. The system will confirm successful registration.
    • Para salir, presione *.
  2. Adding a PIN:
    • Ingrese al modo de programación.
    • Prensa 2 to enter the "Add PIN" menu.
    • Enter the desired 4-6 digit PIN, then press #. Re-enter the PIN and press # again to confirm. The system will confirm successful registration.
    • Para salir, presione *.
  3. Agregar una huella digital:
    • Ingrese al modo de programación.
    • Prensa 3 to enter the "Add Fingerprint" menu.
    • Place a finger on the fingerprint scanner. Lift and repeat the process 3 times as prompted by the system for accurate registration. The system will confirm successful registration.
    • Para salir, presione *.
  4. Eliminación de usuarios:
    • Ingrese al modo de programación.
    • To delete a specific user (card, PIN, or fingerprint), refer to the keypad's on-screen menu for the "Delete User" option (usually option 4 or 5). Follow the prompts to enter the user ID or present the credential to be deleted.
    • To delete all users, refer to the keypad's on-screen menu for the "Delete All Users" option.
    • Para salir, presione *.

5.3 Métodos de desbloqueo

Once users are registered, they can unlock the door using their assigned credentials:

  • Unlock by RFID Card: Present the registered RFID card to the keypad's card reader. The lock will disengage.
  • Desbloqueo por PIN: Enter the registered PIN on the keypad, then press #. The lock will disengage.
  • Unlock by Fingerprint: Place a registered finger on the fingerprint scanner. The lock will disengage.
  • Unlock by Infrared Wireless Switch: Wave your hand in front of the infrared exit switch on the inside of the door. The lock will disengage.

5.4 Vídeo de demostración operativa

Watch this video for a visual guide on adding users and unlocking the system using various methods:

Video 5.4.1: Demonstration of adding RFID cards, PINs, and fingerprints, and unlocking the system using these methods, including the infrared exit switch.

6. Mantenimiento

  • Limpieza: Use a soft, dry cloth to clean the keypad and magnetic lock. Avoid abrasive cleaners or solvents.
  • Sensor de huellas dactilares: Keep the fingerprint sensor clean and free of dust or debris for accurate readings.
  • Alambrado: Revise periódicamente todas las conexiones del cableado para asegurarse de que estén seguras y libres de daños.
  • Cerradura magnética: Ensure the magnetic lock and armature plate are free of obstructions and properly aligned.

7. Solución de problemas

ProblemaPosible causaSolución
El sistema no se enciende.No power to the power supply; loose wiring connection.Check power outlet, power cable, and all wiring connections to the power supply.
Magnetic lock does not engage/disengage.Incorrect wiring; insufficient power; misalignment of lock and plate.Verify wiring according to the diagram. Ensure power supply is providing correct voltage. Check alignment and clear any obstructions.
RFID card/Fingerprint/PIN not recognized.Credential not registered; incorrect entry; dirty sensor.Ensure the credential is properly registered. Re-enter PIN carefully. Clean fingerprint sensor. Try re-registering the credential.
Infrared exit switch not working.Obstruction; wiring issue; sensor malfunction.Ensure nothing is blocking the sensor. Check wiring to the exit switch.

8. Garantía y soporte

For warranty information and technical support, please refer to the product packaging or contact YUANWIN customer service directly. Contact details can typically be found on the manufacturer's website or the product's retail page.

© 2025 YUANWIN. All rights reserved.