KETOTEK D52-2047HD

KETOTEK AC 40-300V 100A Single-Phase Digital Energy Meter

Manual de instrucciones

1. Introducción

The KETOTEK AC 40-300V 100A Single-Phase Digital Energy Meter is a versatile device designed for accurate measurement and display of various electrical parameters. This meter is suitable for DIN rail installation and provides real-time data for voltage, current, active power, energy consumption, frequency, and power factor.

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your energy meter. Please read it thoroughly before use.

2. Características principales

  • 6-in-1 Multimeter: Muestra simultáneamente el volumen de CAtage (40-300V), AC Current (0-100A), Active Power (0-30000W), Electric Energy (0-99999kWh), Frequency (45-65Hz), and Power Factor (0-1PF).
  • Pantalla LCD de alta definición: Features a colorful HD LCD screen with a 178° wide viewing angle and backlight function for clear visibility in various lighting conditions.
  • Durable y confiable: Constructed from high-quality ABS flame-retardant material with a high-precision chip, ensuring safe operation, good electromagnetic anti-interference, low power consumption, and long service life.
  • Data Retention and Reset: Automatically saves electrical energy data upon power loss and resumes accumulation when power is restored. A dedicated reset button allows for clearing accumulated data.
  • Amplia aplicación: Suitable for various environments including schools, markets, homes, industrial settings, and laboratories. Capable of measuring non-standard sine waves from inverters.
KETOTEK 6-in-1 Electricity Meter displaying AC Current, Power Factor, Frequency, AC Voltage, Active Power, and Electricity Consumption (KWh).

KETOTEK 6-in-1 Electricity Meter displaying AC Current, Power Factor, Frequency, AC Voltage, Active Power, and Electricity Consumption (KWh).

3. Especificaciones

Parámetro Valor
Fabricante KETOTEK
Número de modelo D52-2047HD
Dimensiones (L x An x Al) 5.4 x 6.4 x 8 cm
Peso 141 gramos
Volumentage Rango CA 40-300 V
Rango actual 0-100A
Rango de potencia activa 0-30000 W
Gama de energía eléctrica 0-99999kWh
Rango de frecuencia 45-65 Hz
Rango de factor de potencia 0-1 PF
Material abdominales
Tipo de pantalla Pantalla LCD
Proceso de dar un título CE
Product parameters for the KETOTEK energy meter, showing ranges for Voltage, Current, Frequency, Power Factor, Electric Energy, and Power.

Product parameters for the KETOTEK energy meter, showing ranges for Voltage, Current, Frequency, Power Factor, Electric Energy, and Power.

Technical drawing with precise dimensions of the KETOTEK single-phase energy meter, indicating its length, width, height, and DIN rail installation compatibility.

Technical drawing with precise dimensions of the KETOTEK single-phase energy meter, indicating its length, width, height, and DIN rail installation compatibility.

4. Información de seguridad

ADVERTENCIA: Installation and maintenance should only be performed by qualified personnel to prevent electric shock or damage to the device. Always disconnect power before working on electrical circuits.

  • Ensure the power supply is completely disconnected before installation or wiring.
  • Verificar que el voltage and current ratings of the meter match your application requirements.
  • No opere el dispositivo en mojado o damp condiciones.
  • Avoid exposing the meter to direct sunlight or extreme temperatures.
  • Utilice equipo de protección personal (EPP) adecuado durante la instalación.

5. Instalación

5.1 Montaje en carril DIN

The KETOTEK energy meter is designed for standard 35mm DIN rail installation. Simply clip the meter onto the DIN rail in your electrical panel.

Image showing the KETOTEK energy meter installed on a 35mm DIN rail within an electrical panel, demonstrating its compact integration.

The KETOTEK energy meter installed on a 35mm DIN rail within an electrical panel.

5.2 Instrucciones de cableado

Refer to the wiring diagram below for correct connection. The meter requires both a live (L) and neutral (N) connection for its own power supply and for voltage measurement. For current measurement, one of the load cables (either live or neutral) must pass through the integrated current transformer hole.

  • Conecte el volumen de entrada de CAtage (Live and Neutral) to terminals 1 and 2 of the meter.
  • Pass one of the load cables (Live or Neutral) through the current sensing hole on the right side of the meter. The direction in which the cable passes through the hole does not affect the measurement.
  • Asegúrese de que todas las conexiones estén seguras y adecuadamente aisladas.
  • For three-phase systems, connect only one live wire and the neutral wire to the meter for measurement.
Wiring diagram illustrating two common connection methods for the KETOTEK single-phase energy meter with circuit breakers and loads. The diagram shows the input AC voltage (L and N) connected to the meter, and the load connected through the meter's current sensing hole.

Wiring diagram for the KETOTEK single-phase energy meter, showing connections with circuit breakers and loads.

Diagram detailing the integrated current transformer of the KETOTEK energy meter. It shows the AC input (L and N) and how one of the load cables (Live or Neutral) passes through the 10mm diameter hole for current measurement, emphasizing that the direction does not affect accuracy.

Detailed diagram of the integrated current transformer, showing how to pass the load cable through the 10mm hole.

6. Operación

6.1 Encendido

Once properly wired and power is supplied, the meter will automatically power on and display the measured electrical parameters on its LCD screen.

6.2 modos de visualización

The meter cycles through different display screens, showing various parameters such as voltage, current, active power, energy, frequency, and power factor. The colorful HD LCD ensures clear readability.

Collage of various KETOTEK energy meters in different application settings, displaying real-time electrical measurements such as power, energy, voltage, y frecuencia.

Examples of the KETOTEK energy meter displaying real-time electrical measurements in various applications.

6.3 Data Reset

To reset the accumulated electrical energy (kWh) data, press and hold the blue "RESET" button on the front panel for approximately five seconds. The energy value will reset to zero.

The meter automatically stores the accumulated energy data even if power is interrupted. When power is restored, it will continue to accumulate from the last saved value.

7. Solución de problemas

  • Sin pantalla: Compruebe si el volumen de entrada de CAtage is correctly connected to terminals 1 and 2 and within the specified range (AC 40-300V). Ensure power is supplied to the circuit.
  • Current/Power Reading is Zero: Verify that one of the load cables is correctly passed through the integrated current transformer hole. Ensure there is an active load drawing current.
  • Lecturas inexactas: Confirm that the wiring is correct according to the diagram. Ensure the meter is not exposed to strong electromagnetic interference.
  • Pantalla parpadeante: While some minor fluctuations in decimal values are normal for real-time measurements, ensure stable power supply. If flickering is excessive or constant, recheck connections.

8. Mantenimiento

  • Mantenga el medidor limpio y sin polvo. Utilice un paño suave y seco para limpiarlo. No utilice limpiadores abrasivos ni disolventes.
  • Regularly inspect wiring connections to ensure they remain tight and secure.
  • Evite el impacto físico o la caída del dispositivo.
  • No user-serviceable parts inside. Do not attempt to open or repair the meter yourself.

9. Garantía y soporte

Los productos KETOTEK se fabrican con altos estándares de calidad. Para obtener información sobre la garantía o asistencia técnica, consulte los datos de contacto que se incluyen con su compra o visite el sitio web oficial de KETOTEK. websitio.

Conserve su comprobante de compra para cualquier reclamo de garantía.