1. Introducción
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your VEVOR Deep Well Submersible Pump Bundle. This bundle includes two high-quality deep well submersible pumps: a 2HP model and a 1HP model. Both pumps are constructed from durable stainless steel and feature reliable copper motors. Please read this manual thoroughly before using the product and retain it for future reference.
2. Información importante de seguridad
Always follow basic safety precautions to reduce the risk of fire, electric shock, and personal injury. Failure to follow these instructions may result in serious injury or property damage.
- Asegúrese de que la fuente de alimentación coincida con el volumen de la bomba.tagy requisitos.
- Desconecte siempre la alimentación antes de realizar cualquier trabajo de instalación, mantenimiento o reparación.
- No opere la bomba en entornos inflamables o explosivos.
- Do not run the pump dry. Ensure the pump is fully submerged in water before operation.
- Use appropriate lifting equipment when handling the pump due to its weight.
- Todas las conexiones eléctricas deben ser realizadas por un electricista calificado y cumplir con los códigos locales.
- Proteja el cable de alimentación de objetos afilados, calor y aceite.
3. Producto terminadoview y componentes
The VEVOR Deep Well Submersible Pump Bundle includes two distinct pumps designed for efficient water extraction from wells, reservoirs, rivers, and other sources. Both pumps are 4-inch diameter units, featuring upgraded waterproof IP68 construction and a 33 ft power cord.

Image: The VEVOR Deep Well Submersible Pump Bundle, illustrating both the 2HP and 1HP submersible pumps along with a control box, ready for installation.
Características principales:
- Construcción duradera: Both pumps are made of full stainless steel, offering corrosion resistance and longevity.
- Reliable Motors: Equipped with copper motors featuring built-in thermal protection to prevent overheating.
- Válvula de retención integrada: Prevents backflow of water, reducing stress on the pump and piping system.
- Filtración incorporada: Designed to block debris and protect the pump's internal components.
- External Control Box: Included for convenient operation and protection.
4. Especificaciones técnicas
4.1. 2HP Deep Well Submersible Pump

Image: The 2HP VEVOR Deep Well Submersible Pump, shown with its external control box, operating in an agricultural irrigation setting.
| Especificación | Valor |
|---|---|
| Fuerza | 2 CV |
| Caudal máximo | 37 GPM (8400 L/h) |
| Elevación máxima de la cabeza | 427 pies (130 m) |
| Impulsor Stages | 12 (Thermoplastic) |
| Diámetro de la bomba | 4 pulgadas |
| Material | Acero inoxidable |
| Longitud del cable de alimentación | 33 pies |
| Clasificación de impermeabilidad | IP68 |
| Fuente de poder | Eléctrico con cable |

Image: A diagram illustrating the installation of the 2HP submersible pump, highlighting its maximum flow rate of 37 GPM and maximum head lift of 427 feet.
4.2. 1HP Deep Well Submersible Pump

Image: The 1HP VEVOR Deep Well Submersible Pump, shown operating in an agricultural irrigation setting, similar to the 2HP model.
| Especificación | Valor |
|---|---|
| Fuerza | 1 CV |
| Caudal máximo | 37 GPM (8400 L/h) |
| Elevación máxima de la cabeza | 207 pies (63 m) |
| Impulsor Stages | 6 (Thermoplastic) |
| Diámetro de la bomba | 4 pulgadas |
| Material | Acero inoxidable |
| Longitud del cable de alimentación | 33 pies |
| Clasificación de impermeabilidad | IP68 |
| Fuente de poder | Eléctrico con cable |

Image: A diagram illustrating the installation of the 1HP submersible pump, highlighting its maximum flow rate of 37 GPM and maximum head lift of 207 feet.
5. Instalación y configuración
Una instalación correcta es crucial para el rendimiento y la durabilidad de la bomba. Consulte con un profesional cualificado si tiene dudas sobre algún paso.
5.1. Comprobaciones previas a la instalación
- Inspeccione la bomba para detectar cualquier daño visible causado por el envío.
- Verificar que el pozo casing diameter is sufficient for the 4-inch pump.
- Asegúrese de que la fuente de alimentación voltage and frequency match the pump's requirements.
- Gather all necessary tools and materials, including appropriate piping, wiring, and safety equipment.
5.2. Conexión eléctrica
The pump comes with a 33 ft power cord and an external control box. All electrical work must comply with local electrical codes.
- Mount the control box in a dry, accessible location, protected from weather.
- Connect the pump's power cord to the control box terminals as indicated in the control box wiring diagram.
- Connect the main power supply to the control box. Ensure proper grounding.
- Test the electrical connections before submerging the pump.
5.3. Pump Submersion
- Attach the discharge pipe to the pump outlet. Ensure a watertight seal.
- Secure a safety rope or cable to the pump's lifting eye to prevent accidental dropping into the well.
- Carefully lower the pump into the well, ensuring it remains vertical. Do not use the power cable to lower the pump.
- Ensure the pump is fully submerged and positioned at a suitable depth, typically at least 10-20 feet above the bottom of the well to avoid drawing sediment.
- Secure the safety rope/cable at the wellhead.
6. Operación
Once installed, operating the VEVOR submersible pump is straightforward.
6.1. Arrancar la bomba
- Ensure all connections are secure and the pump is properly submerged.
- Turn on the main power supply to the control box.
- Engage the switch on the control box to the 'ON' position. The pump should start operating.
- Monitor the water flow and pressure to ensure proper function.
6.2. Stopping the Pump
- Switch the control box to the 'OFF' position.
- If the pump will not be used for an extended period, disconnect the main power supply.
7. Mantenimiento
El mantenimiento regular garantiza un rendimiento óptimo y prolonga la vida útil de su bomba.
7.1. Controles de rutina
- Periodically check the control box for any signs of moisture or damage.
- Inspect the power cord for wear, cuts, or fraying.
- Monitor pump performance for any changes in flow rate or unusual noises.
7.2. Cleaning and Inspection
If the pump needs to be pulled from the well:
- Disconnect all power before retrieving the pump.
- Carefully lift the pump using the safety rope/cable.
- Clean any accumulated sediment or debris from the pump's intake screen and exterior.
- Inspect the impellers for wear or damage.
- Check all connections and seals for integrity.
7.3. Preparación para el invierno (para climas fríos)
If the pump is installed in an area subject to freezing temperatures and will not be used, it is recommended to:
- Drain all water from the discharge piping to prevent freezing and damage.
- If possible, remove the pump from the well and store it in a warm, dry place.
8. Solución de problemas
This section addresses common issues you might encounter with your VEVOR submersible pump.
| Problema | Posible causa | Solución |
|---|---|---|
| La bomba no arranca | No power; tripped circuit breaker; faulty control box; motor overload. | Check power supply; reset breaker; inspect control box wiring; allow motor to cool if overheated. |
| Bajo caudal/presión de agua | Clogged intake screen; worn impellers; low well water level; pipe leakage. | Clean intake screen; inspect/replace impellers; check well water level; inspect piping for leaks. |
| La bomba funciona pero no hay agua | Pump not submerged; air lock; faulty check valve; severe pipe blockage. | Ensure pump is submerged; prime the system if possible; check/replace check valve; clear pipe blockage. |
| La bomba realiza ciclos con frecuencia | Pressure tank issue; small leak in system; faulty pressure switch. | Check pressure tank air charge; inspect system for leaks; test/replace pressure switch. |
Si los pasos de solución de problemas no resuelven el problema, comuníquese con el servicio de atención al cliente.
9. Garantía y atención al cliente
VEVOR products are designed for reliability and durability. This product is ETL certified with an IP68 waterproof rating, indicating a design for long-term service.
For warranty information, technical assistance, or to report issues, please refer to the contact details provided with your purchase documentation or visit the official VEVOR website. When contacting support, please have your product model and purchase date available.