Introducción
This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your Marey GA10FNG 2.64 GPM Natural Gas Tankless Water Heater. Please read all instructions carefully before installation and use to ensure proper function and safety.
The Marey GA10FNG is a compact, flow-activated natural gas tankless water heater designed to provide hot water on demand. It features a 68,240 BTU heating capacity and a flow rate of 2.64 GPM, making it suitable for various applications including small homes, cabins, and off-grid setups. The unit operates without an electrical connection for ignition, utilizing two D batteries instead.
Video: Un sobreview of the Marey Flow Series tankless water heaters, highlighting key features and benefits of the design and technology.
Características principales
- Diseño compacto: Ideal for small spaces, offering efficient hot water supply without a large footprint.
- Capacidad fuera de la red: Pulse ignition requires no electrical connection, operating on two D batteries.
- Flow Activation: Activates with low water pressure, providing 2.64 GPM output.
- Control de temperatura: Features a summer/winter switch and adjustable manual temperature control for year-round customization.
- Seguridad mejorada: Equipped with twin solenoid valves for water and gas connections, and multiple safety sensors including auto cut-off, automatic ignition, anti-dry combustion, over-pressure, overheating, and flameout protection.
- Eficiencia Energética: Oxygen-free heat exchanger improves heat conductivity and reduces gas consumption in warmer months.
- Debris Protection Grid: Integrated grid for increased unit longevity by preventing debris entry.

Imagen: Visual representation of the water heater's key features, including compact design, no electricity requirement, flow activation, flame out protection, and oxygen-free heat exchanger.
Configuración e instalación
Una instalación correcta es crucial para el funcionamiento seguro y eficiente de su calentador de agua sin tanque. Se recomienda que la instalación la realice un profesional cualificado.
Requisitos de ubicación
- The unit is designed for wall mounting. Ensure the mounting surface is sturdy and capable of supporting the unit's weight (approximately 10.14 pounds).
- Instalar en un área bien ventilada.
- The unit is not recommended for elevations above 2,000 feet.
- Ensure adequate clearance around the unit for maintenance and proper ventilation.
Conexiones
- Conexión de gas: The unit operates on Natural Gas (NG). The gas connection size is 1.5-inch NPT. Ensure all gas connections are sealed properly and checked for leaks.
- Conexión de agua: The water connection is located at the bottom of the unit, with a size of 1.5-inch NPT. Connect the cold water inlet and hot water outlet according to the markings on the unit.
- Ventilación: A 4-inch diameter vent is required for proper exhaust. Ensure the vent pipe is installed correctly and extends to the outside.
Instalación de la batería
- The unit requires two D batteries for pulse ignition. Locate the battery compartment, typically on the bottom or side of the unit.
- Inserte las baterías, asegurándose de la polaridad correcta.

Imagen: Frente view of the Marey GA10FNG water heater, showing its compact design and control knobs.

Imagen: Atrás view of the Marey GA10FNG water heater, illustrating the mounting brackets and connection points for gas, water, and exhaust.
Instrucciones de funcionamiento
Puesta en marcha inicial
- Ensure gas and water supplies are connected and turned on.
- Verify that the two D batteries are correctly installed for ignition.
- Open a hot water faucet. The unit will automatically activate and begin heating water.
Control de temperatura
- Perilla de flujo de agua: Adjusts the water flow rate. Higher flow rates may result in slightly lower outlet temperatures, while lower flow rates allow for higher temperatures.
- Perilla de flujo de gas: Controls the gas supply to the burner, directly impacting the heating power and water temperature. Turn towards 'Max' for hotter water and 'Min' for cooler water.
- Summer/Winter Switch: This switch allows for seasonal adjustment of heating power.
- Modo Verano: Reduces gas consumption, suitable for warmer months when incoming water temperature is higher.
- Modo de invierno: Increases gas consumption for colder months when incoming water temperature is lower, requiring more heat to reach desired output temperature.
Nota: Sufficient water flow (minimum activation rate: 0.66 GPM) is required for the unit to activate and prevent the overheat safety sensor from shutting off the unit.

Imagen: Detallado view of the water heater's control panel, showing the water flow knob, gas flow knob, and the summer/winter switch for temperature adjustment.
Mantenimiento
Regular maintenance ensures the longevity and efficient operation of your Marey tankless water heater. It is recommended to have the unit inspected annually by a qualified technician.
- Limpieza del intercambiador de calor: Periodically inspect and clean the oxygen-free heat exchanger to maintain optimal heat conductivity and energy efficiency.
- Debris Protection Grid: Check the debris protection grid regularly for any accumulated leaves or other foreign objects and clean as necessary to ensure proper airflow and prevent damage.
- Reemplazo de batería: Replace the D batteries when the ignition becomes inconsistent or fails to ignite.
- Sistema de ventilación: Asegúrese de que el tubo de ventilación esté libre de obstrucciones y correctamente sellado.
- Calidad del agua: In areas with hard water, consider installing a water softener or descaling the unit periodically to prevent mineral buildup.
Solución de problemas
This section provides solutions to common issues you might encounter. For complex problems, contact a qualified technician or Marey customer support.
| Problema | Posible causa | Solución |
|---|---|---|
| No hay agua caliente / La unidad no enciende |
|
|
| El agua no está lo suficientemente caliente |
|
|
| La unidad se enciende y se apaga rápidamente |
|
|
Presupuesto
| Característica | Detalle |
|---|---|
| Número de modelo | GA10FNG |
| Marca | MAREY |
| Tipo de combustible | Gas natural (GN) |
| Calificación BTU | 68,240 BTU |
| Caudal máximo | 2.64 galones por minuto (GPM) |
| Minimum Activation Rate | 0.66 GPM |
| Presión nominal | 0.406 PSI |
| Gas/Water Connection Size | NPT de 1.5 pulgada |
| Ubicación de la conexión de agua | Abajo |
| Diámetro de ventilación | 4 pulgadas |
| Dimensiones (An x Al x Pr) | 11.42 x 17.01 x 4.65 pulgadas |
| Peso | 10.14 libras |
| Encendido | Pulse ignition (2 x D batteries, not included) |
| Tipo de montaje | Muro |
| Características especiales | Overheat Protection, Oxygen Free Heat Exchanger, Twin Solenoid Valves |

Imagen: Dimensional drawing of the Marey GA10FNG water heater, indicating its width and height for installation planning.
Garantía y soporte
The Marey GA10FNG Tankless Water Heater comes with a Garantía limitada de 5 años. For warranty claims, technical support, or service inquiries, please contact Marey customer service. Keep your proof of purchase for warranty validation.
For further assistance, refer to the official Marey websitio o comuníquese con sus canales de soporte.