SENSOR INTELIGENTE AS8906

SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector User Manual

Modelo: AS8906

1. Introducción

This manual provides instructions for the safe and effective operation of the SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector. This device is designed for detecting Nitrogen Dioxide (NO2) gas concentrations in various environments. Please read this manual thoroughly before using the product.

1.1 Información de seguridad

  • Always operate the device in accordance with the instructions provided.
  • No intente modificar ni reparar el dispositivo usted mismo. Para obtener servicio técnico, contacte con personal cualificado.
  • Ensure the device is charged using the provided charging adapter and USB cable.
  • Avoid exposing the device to extreme temperatures or humidity outside the specified operating conditions.
  • This device is intended for professional use and should be handled with care.

2. Producto terminadoview

2.1 Contenido del paquete

El paquete estándar incluye los siguientes elementos:

  • 1 x Nitrogen Dioxide Gas Monitor (AS8906)
  • 1 x Manual de usuario
  • 1 x adaptador de carga
  • 1 x cable USB
  • 1 x Hand Carry Case
  • 1 certificado de calibración.
  • 1 x CNEX Certificate
  • 1 x Gift Paper Box
Standard package contents of the SMART SENSOR AS8906 gas detector, including the device, carry case, charger, and documentation.

Figura 2.1: Contenido del paquete estándar.

2.2 Componentes del dispositivo

Familiarize yourself with the main components of the AS8906 detector:

Frente view of the SMART SENSOR AS8906 NO2 gas detector with labeled components: High sensitive sensor, sampling pump connecting port, LCD screen, Down button, Up button, Sound alarm, Charging port, Light alarm, Power on/off button, Enter button.

Figura 2.2: Frente view and labeled components of the AS8906 detector.

  • High Sensitive Sensor: Detects NO2 gas concentration.
  • Sampling Pump Connecting Port: For attaching the optional sampbomba de agua
  • Pantalla LCD: Displays gas concentration, battery status, and other information.
  • Botón Abajo: Se utiliza para navegación y decreasinvalores g.
  • Botón de arriba: Se utiliza para navegación e incrementoasinvalores g.
  • Alarma de sonido: Emits an audible alert when gas concentration exceeds set limits.
  • Puerto de carga: Para conectar el cable de carga USB.
  • Alarma de luz: Visual alert (LED) when gas concentration exceeds set limits.
  • Botón de encendido / apagado: Controla la energía del dispositivo.
  • Botón Entrar: Confirma selecciones y configuraciones.

2.3 Dimensiones

The AS8906 detector features a compact design for portability.

Lado a lado view of the SMART SENSOR AS8906 NO2 gas detector showing its dimensions: 120mm height, 64.5mm width, and 38.3mm depth.

Figura 2.3: Dimensiones del dispositivo.

Dimensions: 120.2mm (Height) x 64.5mm (Width) x 38.3mm (Depth).

A person's hand placing the compact SMART SENSOR AS8906 NO2 gas detector into a jeans pocket, illustrating its portability.

Figure 2.4: The compact size allows for easy portability.

3. Configuración

3.1 Carga del dispositivo

The AS8906 detector is powered by a built-in 3.7V Li-battery. Before first use, ensure the device is fully charged.

  1. Localice el puerto de carga en la parte inferior del dispositivo.
  2. Conecte el cable USB proporcionado al puerto de carga.
  3. Connect the other end of the USB cable to the charging adapter.
  4. Plug the charging adapter into a standard power outlet.
  5. The battery indicator on the LCD screen will show charging status. A full charge typically provides up to 12 hours of continuous operation.
De cerca view of the bottom of the SMART SENSOR AS8906 NO2 gas detector, highlighting the battery charging port.

Figura 3.1: Ubicación del puerto de carga.

The SMART SENSOR AS8906 NO2 gas detector connected to its charging adapter and USB cable.

Figure 3.2: Gas detector with recharge adapter.

3.2 Conexión del SampBomba de agua (opcional)

The optional sampling pump (AS8930) is designed to assist the gas detector in environments with limited access or poor air circulation. It does not operate independently and requires power from the gas detector.

  1. Alinear la sampling pump with the gas detector's sampling pump connecting port.
  2. Securely attach the sampling pump to the gas detector using the two closed-type screws. Ensure a tight connection to avoid poor contact.
  3. Connect the soft rubber tube (500mm long) to the nozzle of the sampbomba de agua
  4. Importante: Do not connect any other voltage power supply to the sampling pump to prevent damage.
Componentes de la sampling pump accessory, including the pump unit, user manual, warranty card, soft rubber tube, and color paper box.

Figura 3.3: Sampling pump and accessories.

4. Operación

4.1 Encendido / Apagado

  • Para encender: Mantenga pulsado el Botón de encendido/apagado until the LCD screen illuminates. The device will perform a self-test.
  • Para apagar: Mantenga pulsado el Botón de encendido/apagado hasta que la pantalla se apague.

4.2 Comprender la pantalla

The high-density digital LCD screen displays real-time gas concentration values, battery status, and other operational indicators. The backlight function allows for use in dark areas.

  • PPM: Indicates parts per million, the unit for gas concentration.
  • Icono de batería: Muestra el nivel de carga actual de la batería.
  • Indicadores de alarma: Visual cues for alarm status.

4.3 funciones de alarma

The device features high and low alarm functions with three alert methods: sound, light, and vibration. Alarm values are adjustable.

  • When the gas concentration reaches a preset high or low alarm value, the device will activate its sound, light, and vibration alarms.
  • The alarm sound can reach up to 80dB.

4.4 Adjusting Alarm Values

Refer to the on-screen menu for adjusting high and low alarm thresholds. Use the Up y Abajo buttons to navigate and change values, and the Ingresar Botón para confirmar.

4.5 Using the Sampbomba de ling

Cuando el sampling pump is connected, it will draw air into the detector, allowing for gas concentration measurement in remote or confined spaces. The air flow velocity is approximately 0.5 cubic inches per hour, with a maximum gas sample collecting distance of about 50 feet.

5. Mantenimiento

5.1 Cuidado de la batería

  • Recharge the device when the battery indicator shows low power to ensure continuous operation.
  • Evite descargar completamente la batería con frecuencia para prolongar su vida útil.
  • Si va a almacenar el dispositivo durante un período prolongado, cárguelo aproximadamente al 50 % y recárguelo cada pocos meses.

5.2 Limpieza

  • Limpie el exterior del dispositivo con un paño suave yamp paño.
  • No utilice limpiadores abrasivos ni disolventes, ya que pueden dañar el casing o pantalla.
  • Ensure no liquids enter the sensor area or charging port.

5.3 Calibración

The device comes with a calibration certificate. For optimal accuracy and compliance, periodic professional calibration is recommended. Refer to the manufacturer or authorized service centers for calibration services.

6. Solución de problemas

If you encounter issues with your AS8906 detector, refer to the following common problems and solutions:

ProblemaPosible causaSolución
El dispositivo no se enciende.Batería baja o agotada.Cargue el dispositivo utilizando el adaptador y el cable USB proporcionados.
Lecturas inexactas.Sensor contamination or need for calibration.Ensure the sensor area is clean. Consider professional calibration if readings remain inconsistent.
Alarm not sounding/lighting/vibrating.Alarm settings configured incorrectly or disabled.Check alarm settings in the device menu. Ensure volume and vibration are enabled.
Sampling pump not working.Poor connection to the detector or pump malfunction.Asegúrese de que el sampling pump is securely attached with screws. Verify the detector is powered on.

Si el problema persiste después de intentar estas soluciones, comuníquese con el servicio de atención al cliente para obtener más ayuda.

7. Especificaciones

7.1 Especificaciones del detector

CaracterísticaDetalle
MarcaSENSOR INTELIGENTE
ModeloAS8906
Tipo de gasDióxido de nitrógeno (NO2)
Rango de medición0 ~ 20 ppm
Resolución0.1 ppm
Principio de funcionamientoSensor electroquímico
Tipo de alarmaSound, Light, Vibration (adjustable values)
Nivel de sonido de la alarmaHasta 80dB
Temperatura de funcionamiento-10 ~ 50 °C
Humedad de funcionamiento15~95% RH (standard)
Fuente de poder3.7V Li-battery (Built-in)
Corriente de trabajo16 mA
Operación continuaAprox. 12 horas (carga completa)
MaterialPlástico ABS
Peso neto200 g (7.1 onzas)
Dimensiones120.2 x 64.5 x 38.3 mm
CertificacionesJJG693; JJG695: JJG915 and GB3836 series anti-explosion standard, CNEX

7.2 Sampling Pump Specifications (Optional Accessory)

CaracterísticaDetalle
Vol de funcionamientotage RangoCC 2.2 V-3.2 V
Corriente de trabajo<280 mA
Diámetro de la boquilla2.5 mm
Ruido<75dB
Dimensiones100.8 x 62.3 x 50 mm
Máximo Sample DistanceAprox. Pies 50
Air Flow VelocityApprox. 0.5 cubic inches per hour

8. Garantía y soporte

8.1 Información de garantía

Your SMART SENSOR AS8906 Handheld NO2 Gas Leak Detector comes with a warranty. Please refer to the included Warranty Card in your package for specific terms and conditions, including warranty period and coverage details.

8.2 Atención al cliente

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact SMART SENSOR customer support. Contact information can typically be found on the product packaging, the warranty card, or the official SMART SENSOR websitio.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.