Danfoss 071N0107

Danfoss BFP 21 L3 Oil Burner Pump (Model 071N0107) Instruction Manual

1. Introducción

This instruction manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss BFP 21 L3 Oil Burner Pump, model 071N0107. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent damage or injury.

2. Información de seguridad

ADVERTENCIA: To prevent health and bodily harm, installation, maintenance, initial commissioning, repairs, and other inspections must be carried out by authorized professionals, such as contractual installation companies or qualified technicians. Improper installation or service can lead to serious injury or equipment damage.

  • Always disconnect power to the burner system before performing any work on the pump.
  • Utilice equipo de protección personal (EPP) adecuado durante la instalación y el mantenimiento.
  • Asegúrese de que todas las conexiones sean seguras y sin fugas para evitar riesgos de incendio.
  • No opere la bomba si está dañada o no funciona correctamente.

3. Producto terminadoview

The Danfoss BFP 21 L3 is a high-quality oil burner pump designed for reliable fuel delivery in heating systems. This model, 071N0107, is a direct replacement for the BFP 31 series and features a left rotation and an 8 mm shaft diameter.

Danfoss BFP 21 L3 Oil Burner Pump, front view

Figura 3.1: Frente view of the Danfoss BFP 21 L3 Oil Burner Pump. This image shows the main body of the pump with its shaft extending forward, ready for connection to a motor.

Danfoss BFP 21 L3 Oil Burner Pump, side view con etiqueta

Figura 3.2: Lado view of the Danfoss BFP 21 L3 Oil Burner Pump, highlighting the product label. The label clearly displays "BFP 21 L3" and "071N0107", along with other technical markings and certifications.

Danfoss BFP 21 L3 Oil Burner Pump, rear view de eje

Figura 3.3: Posterior view of the Danfoss BFP 21 L3 Oil Burner Pump, focusing on the shaft connection point. This perspective shows the robust construction around the shaft, indicating its connection to the burner motor.

Características principales:

  • Model: BFP 21 L3 (071N0107)
  • Replaces: BFP 31 series
  • Rotation: Left
  • Shaft Diameter: 8 mm

4. Configuración e instalación

Installation of the Danfoss BFP 21 L3 oil burner pump should only be performed by a qualified technician. Incorrect installation can lead to system malfunction, fuel leaks, or fire hazards. The following steps are general guidelines; always refer to the specific burner manufacturer's instructions and local codes.

  1. Preparación: Ensure the burner system is completely shut down and power is disconnected. Close all fuel supply valves.
  2. Retirada de la bomba vieja: Carefully disconnect fuel lines and electrical connections from the old pump. Note the orientation and connections for proper reinstallation. Remove mounting bolts and detach the old pump.
  3. Mounting the New Pump: Position the new Danfoss BFP 21 L3 pump, ensuring the shaft aligns correctly with the motor coupling. Secure the pump using the appropriate mounting bolts.
  4. Connecting Fuel Lines: Connect the suction and return fuel lines to the designated ports on the pump. Ensure all connections are tight and sealed to prevent leaks.
  5. Conexiones eléctricas: Reconnect electrical wiring according to the burner manufacturer's diagram. Verify correct polarity and secure all connections.
  6. Cebado de la bomba: After installation, the pump may need to be primed to remove air from the fuel lines. Follow the burner manufacturer's procedure for priming.
  7. Comprobación de fugas: Before full operation, perform a thorough leak check on all fuel connections.
  8. Puesta en marcha inicial: Restore power and fuel supply. Carefully observe the burner's operation during initial start-up, checking for proper ignition and fuel delivery.

5. Instrucciones de funcionamiento

The Danfoss BFP 21 L3 oil burner pump operates as an integral part of your heating system. Once properly installed and commissioned by a professional, its operation is typically automatic, controlled by the burner's control unit.

  • Operación automática: The pump will engage and deliver fuel when the burner control calls for heat.
  • Ajuste de presión: The pump's pressure is factory-set but may require fine-tuning during commissioning. This adjustment should only be performed by a qualified technician using appropriate pressure gauges.
  • Escucha: Regularly monitor your heating system for unusual noises, fuel odors, or performance issues.

6. Mantenimiento

Regular maintenance is crucial for the longevity and efficient operation of your Danfoss BFP 21 L3 oil burner pump and the entire heating system. All maintenance procedures should be carried out by a qualified service technician.

  • Inspección anual: Have the pump and burner system inspected annually by a professional. This includes checking for leaks, wear on components, and proper pressure settings.
  • Reemplazo del filtro: The oil filter (if external to the pump) should be replaced regularly as recommended by the burner manufacturer. A clogged filter can strain the pump and reduce efficiency.
  • Limpieza/reemplazo de boquillas: The burner nozzle should be cleaned or replaced as part of routine maintenance to ensure proper fuel atomization.
  • Comprobación del sello del eje: Inspect the pump shaft seal for any signs of oil leakage. Address any leaks promptly.

7. Solución de problemas

This section provides general troubleshooting tips. For complex issues or if you are unsure, always contact a qualified service technician.

ProblemaPosible causaSolución
El quemador no se enciendeNo fuel delivery, air in lines, clogged nozzle, faulty ignition.Check fuel supply, prime pump, inspect/clean nozzle, check ignition system. Contacte al técnico.
La bomba hace un ruido inusualAir in fuel, worn bearings, foreign object.Check for air leaks in suction line, inspect pump. Contacte al técnico.
Oil leakage from pumpConexiones sueltas, sellos dañados.Tighten connections, replace seals. Contacte al técnico.
Inconsistent flame or poor combustionIncorrect pressure, partially clogged nozzle, air in fuel.Check/adjust pressure, clean/replace nozzle, bleed air. Contacte al técnico.

8. Especificaciones

Below are the key specifications for the Danfoss BFP 21 L3 Oil Burner Pump (Model 071N0107).

  • Fabricante: DANFOSS
  • Número de modelo: 071N0107 / 88.70100-0040
  • Dimensiones del producto: Aproximadamente 10 x 10 x 10 cm (3.94 x 3.94 x 3.94 pulgadas)
  • Peso del artículo: Approximately 1.08 kilograms (2.38 pounds)
  • Rotación: Izquierda
  • Diámetro del eje: 8 milímetros
  • Pilas necesarias: No
  • Pilas incluidas: No
  • ASIN: B07DCVM3WW
  • Fecha de primera disponibilidad: 15 de abril de 2022

9. Garantía y soporte

For warranty information and technical support, please refer to the documentation provided with your purchase or contact your authorized Danfoss dealer or service center. Keep your proof of purchase for warranty claims.

Danfoss does not provide specific information regarding spare parts availability directly to end-users. Please consult with your authorized service provider for spare parts inquiries.

© 2024 Danfoss. All rights reserved. This manual is for informational purposes only.